Analysis of Convection Correlations for a Cylinder in Laminar Cross Flow - PowerPoint PPT Presentation

About This Presentation
Title:

Analysis of Convection Correlations for a Cylinder in Laminar Cross Flow

Description:

Fluent was used to measure the heat transfer characteristics. ... Hilbert: Average Error 9.98% Expected error near the 10% range given in textbook. ... – PowerPoint PPT presentation

Number of Views:65
Avg rating:3.0/5.0
Slides: 12
Provided by: CAE59
Learn more at: http://www.et.byu.edu
Category:

less

Transcript and Presenter's Notes

Title: Analysis of Convection Correlations for a Cylinder in Laminar Cross Flow


1
Analysis of Convection Correlations for a
Cylinder in Laminar Cross Flow
Dan Karpowitz, Jon Day, Ryan Blanchard
  • Fluent was used to measure the heat transfer
    characteristics.
  • Provided data to compare with analytical
    correlations.
  • TS 400 K T8 200K
  • Using theoretical values the Nusselt number was
    calculated.
  • Churchill-Bernstein Average Error 12.75
  • Hilbert Average Error 9.98
  • Expected error near the 10 range given in
    textbook.
  • Comparison of Cd was also made for Fluent and
    theoretical.

2
(No Transcript)
3
(No Transcript)
4
Re 10
5
Re 32
6
Re 100
7
Re 316
8
Re 1000
9
Re 3162
10
Re 1000
11
Re 20000
Write a Comment
User Comments (0)
About PowerShow.com