Grounding Scheme and EMC - PowerPoint PPT Presentation

1 / 9
About This Presentation
Title:

Grounding Scheme and EMC

Description:

Isolation between primary and secondary power. Reduced slope of DC/DC transformer ... Warm Electronics (DEC1, DEC2, BOLC): secondary ground can be connected to S/C ... – PowerPoint PPT presentation

Number of Views:116
Avg rating:3.0/5.0
Slides: 10
Provided by: albrechtp
Category:
Tags: emc | dec1 | grounding | scheme

less

Transcript and Presenter's Notes

Title: Grounding Scheme and EMC


1
Grounding Scheme and EMC
  • Matthias Rumitz, MPE

2
Overview
  • System Diagram
  • Grounding / EMC Concept
  • Mechanism Grounding Concept
  • Detector Grounding Concept
  • Example MEC Grounding
  • Grounding / EMC Status

3
System Diagram
FPU
CREs
LCL
Grating
OBC
MECDEC
SPU
Filters
CDMU
BOLC
BOLA
DPU
S/C
Bolos
CDMU
MECDEC
Temp.Sensors
OBC
SPU
Chopper
LCL
BlackBodies
4
Grounding / EMC Concept
  • Requirements of IID-A (5.10 5.14) implemented
  • Distributed Single Point Grounding
  • DPU, SPU, MEC secondary ground connected to S/C
  • Additional EMC measures (DEC, BOLC) Isolation
    between primary and secondary power Reduced
    slope of DC/DC transformer EMI filter at DC/DC
    secondary side

5
Mechanism Grounding Concept
  • FPU (i.e. mechanisms)electrically connected to
    S/C reference ground
  • Drive circuitsdifferential supply voltages
  • Sensorsdifferential read-out
  • gt no ground loops, EMI risk minimized

6
Detector Grounding Concept
  • FPU (i.e. detector-housing)electrically
    connected to S/C gt reference ground
  • Warm Electronics (DEC1, DEC2, BOLC)secondary
    ground can be connected to S/C
  • Detectors (CREs, bolometers)analog ground can
    be connected to FPU ( S/C)
  • gt reference groundeither Detectors or Warm
    Electronics

7
Example MEC Grounding
  • Warm Interconnecting Harness shorter than 1m

8
Grounding / EMC Status
9
(No Transcript)
10
Redundancy Concept
11
Purpose of Template
  • Create uniform set of presentations
  • Allow easy re-use of parts of presentations on
    other occasions (e.g. status report at
    FIRST/Herschel Science Team meetings)

12
DPU Grounding
13
SPU Grounding