Presentation by: PowerPoint PPT Presentation

presentation player overlay
1 / 14
About This Presentation
Transcript and Presenter's Notes

Title: Presentation by:


1
First National Educational Competition
onPredicting Progressive Collapse Resistance of
Reinforced Concrete Structural Systems
  • Presentation by
  • Jesse Conklin
  • Group Members
  • J.P. Telemaque Mike Milano

Level 1 Undergraduate University of
Massachusetts Amherst
2
Competition OutlineLevel 1 Undergraduate
  • 1/8 scale 2-D model of a RC frame with 3 stories
    and 4 bays
  • 2 Step procedure
  • Instantaneously removing the glass column at
    first floor in the center of the frame
  • If the frame remained standing, the structure was
    tested with static loads only and tested until
    failure
  • Predicted displacements and total static loading
    after instantaneous removal of center column

3
1/8th Model Frame
4
Full Size 2-D Exterior Frame
5
1/8th Scale Model of 2-D Exterior Frame
6
SAP2000 1/8th Scale Analytical Model
7
1/8th Scale Cross-sections
8
Maximum Deflection of Frame
  • Used SAP2000 Analysis for Deflection
  • Actual Results
  • Maximum - .21
  • Residual - .20
  • Calculated Results
  • Maximum - .15
  • Residual - .08

9
Material Properties
  • Dimensions of scaled model are 1/8 of full scale
    model
  • Applied loads are 1/64 of full scale applied
    loading to maintain approximate equal amounts of
    stress as compared to full scale model
  • fc 7,000 psi
  • fy 55 ksi, fu 75 ksi

10
XTract
  • Each cross section was modeled in XTract to
    determine moment-curvature behavior
  • Ultimate moment values from XTract were compared
    to moment values from SAP2000 full size
    analytical model
  • Confined concrete - Mander model

11
SAP2000 Full Size Analytical Model
12
Static Loading
  • 1st Hinge Reached Moment Capacity
  • Section B-B _at_ face of middle column both sides
  • Load 1015 lbs
  • Added pin at plastic hinge location moment
    redistributed, checked deflection and curvature
    capacity
  • 2nd Hinge Reached Moment Capacity
  • Section B-B _at_ 6 ft. from face of column B both
    sides
  • FAILURE
  • Load 1454 lbs
  • Predicted Collapse Load 1454 lbs
  • Actual Collapse Load 1800 lbs

13
Collapse
14
Predicting Collapse Improvements
  • Deflection
  • Correct dimensions of 1/8th scale frame
  • Calculation of Ic
  • Collapse Load
  • XTract 1/8th scale cross-section
    moment-curvature analysis
Write a Comment
User Comments (0)