Title: Long term monitoring for PCB in ambient air using low volume air sampler
1Long term monitoring for PCB in ambient air
using low volume air sampler Hyogo Prefectural
Institute of Public Health and Environmental
Sciences Masahiro Tsurukawa, Chisato Matsumura,
Takeshi Nakano
Background Objectives
- Chemicals that caused Kanemi-yusho
- Designated as POPs(Persistent Organic
Pollutants) - Resident to degradation,Long transfer,High
acuumulation in the ecosystem,Toxity - Influences on the humans and the ecosystem has
been concerned
PCBs (Polychlorinated Biphenyls)
We need to monitor the PCB concentration
carefully because PCB productions are stored in
many dispersed places.
Monitoring was carried out from 2000 to 2005 in
Hyogo prefecture inJapan.Regarding the sampling
location and period, sampling was carried out in
urban, industrial, rural area and collected
continuously for about one month.
PCB usage(t)
Daily variation of Dioxin Concentration(compared
with Hi volume air sampler and Low volume air
sampler)
Low volume air sampling method is effective for
long term monitoring.
Research method
- ?Monitoring was conducted at three points at
Nishiwaki - (rural area),Takasago(industrial area), Suma in
Kobe - (urban area) .
- ?PCB concentrations in each sample were
determined with - high resolution GC/MS (JEOL JMS700).
- GC/MS analysis The analysis was carried out
using a HP 6890 gas chromatograph connected to a
JMS-800D mass spectrometer (JEOL Ltd. Japan)
operating at a resolution gt10 000. Co-PCB, Co-PXB
and PXDF were analyzed using HT8-PCB column.
Temperature program used for congener specific
separation of the PCB, PXB and PXDF on HT8-PCB
column 120C, 20C/min. to 180C, 2C/min. to 260C.
5C/min. to 300C, 5 min. isothermal. Monitoring
ions for GC/MS analysis are listed in Table. - StandaGC/MS analysis The analysis was carried
out using a HP 6890 gas chromatograph connected
to a JMS-800D mass spectrometer (JEOL Ltd. Japan)
operating at a resolution gt10 000. Co-PCB, Co-PXB
and PXDF were analyzed using HT8-PCB column.
Temperature program used for congener specific
separation of the PCB, PXB and PXDF on HT8-PCB
column 120C, 20C/min. to 180C, 2C/min. to 260C.
5C/min. to 300C, 5 min. isothermal. Monitoring
ions for GC/MS analysis are listed in Table. - Standards Commercially-available native/labeled
standards were obtained from CIL as authentic
standard/mixtures for crosschecking the
assignment. , 4-bromo- 3, 3, 4, 5-tetrachloro
biphenyl was obtained from CIL for a PXB
standard. - GC/MS analysis The analysis was carried out
using a HP 6890 gas chromatograph connected to a
JMS-800D mass spectrometer (JEOL Ltd. Japan)
operating at a resolution gt10 000. Co-PCB, Co-PXB
and PXDF were analyzed using HT8-PCB column.
Temperature program used for congener specific
separation of the PCB, PXB and PXDF on HT8-PCB
column 120C, 20C/min. to 180C, 2C/min. to 260C.
5C/min. to 300C, 5 min. isothermal. Monitoring
ions for GC/MS analysis are listed in Table. - Standards Commercially-available native/labeled
standards were obtained from CIL as authentic
standard/mixtures for crosschecking the
assignment. , 4-bromo- 3, 3, 4, 5-tetrachloro
biphenyl was obtained from CIL for a PXB standard
Result and Discussion
Atropisomer in air and adipose tissue (HpCB)