Long term monitoring for PCB in ambient air using low volume air sampler - PowerPoint PPT Presentation

1 / 1
About This Presentation
Title:

Long term monitoring for PCB in ambient air using low volume air sampler

Description:

Long term monitoring for PCB in ambient air using low volume air sampler ... 4'-bromo- 3, 3', 4, 5-tetrachloro biphenyl was obtained from CIL for a PXB standard. ... – PowerPoint PPT presentation

Number of Views:51
Avg rating:3.0/5.0
Slides: 2
Provided by: takab
Category:

less

Transcript and Presenter's Notes

Title: Long term monitoring for PCB in ambient air using low volume air sampler


1
Long term monitoring for PCB in ambient air
using low volume air sampler Hyogo Prefectural
Institute of Public Health and Environmental
Sciences Masahiro Tsurukawa, Chisato Matsumura,
Takeshi Nakano
Background Objectives
  • Chemicals that caused Kanemi-yusho
  • Designated as POPs(Persistent Organic
    Pollutants)
  • Resident to degradation,Long transfer,High
    acuumulation in the ecosystem,Toxity
  • Influences on the humans and the ecosystem has
    been concerned

PCBs (Polychlorinated Biphenyls)
We need to monitor the PCB concentration
carefully because PCB productions are stored in
many dispersed places.
Monitoring was carried out from 2000 to 2005 in
Hyogo prefecture inJapan.Regarding the sampling
location and period, sampling was carried out in
urban, industrial, rural area and collected
continuously for about one month.
PCB usage(t)
Daily variation of Dioxin Concentration(compared
with Hi volume air sampler and Low volume air
sampler)
Low volume air sampling method is effective for
long term monitoring.
Research method
  • ?Monitoring was conducted at three points at
    Nishiwaki
  • (rural area),Takasago(industrial area), Suma in
    Kobe
  • (urban area) .
  • ?PCB concentrations in each sample were
    determined with
  • high resolution GC/MS (JEOL JMS700).
  • GC/MS analysis The analysis was carried out
    using a HP 6890 gas chromatograph connected to a
    JMS-800D mass spectrometer (JEOL Ltd. Japan)
    operating at a resolution gt10 000. Co-PCB, Co-PXB
    and PXDF were analyzed using HT8-PCB column.
    Temperature program used for congener specific
    separation of the PCB, PXB and PXDF on HT8-PCB
    column 120C, 20C/min. to 180C, 2C/min. to 260C.
    5C/min. to 300C, 5 min. isothermal. Monitoring
    ions for GC/MS analysis are listed in Table.
  • StandaGC/MS analysis The analysis was carried
    out using a HP 6890 gas chromatograph connected
    to a JMS-800D mass spectrometer (JEOL Ltd. Japan)
    operating at a resolution gt10 000. Co-PCB, Co-PXB
    and PXDF were analyzed using HT8-PCB column.
    Temperature program used for congener specific
    separation of the PCB, PXB and PXDF on HT8-PCB
    column 120C, 20C/min. to 180C, 2C/min. to 260C.
    5C/min. to 300C, 5 min. isothermal. Monitoring
    ions for GC/MS analysis are listed in Table.
  • Standards Commercially-available native/labeled
    standards were obtained from CIL as authentic
    standard/mixtures for crosschecking the
    assignment. , 4-bromo- 3, 3, 4, 5-tetrachloro
    biphenyl was obtained from CIL for a PXB
    standard.
  • GC/MS analysis The analysis was carried out
    using a HP 6890 gas chromatograph connected to a
    JMS-800D mass spectrometer (JEOL Ltd. Japan)
    operating at a resolution gt10 000. Co-PCB, Co-PXB
    and PXDF were analyzed using HT8-PCB column.
    Temperature program used for congener specific
    separation of the PCB, PXB and PXDF on HT8-PCB
    column 120C, 20C/min. to 180C, 2C/min. to 260C.
    5C/min. to 300C, 5 min. isothermal. Monitoring
    ions for GC/MS analysis are listed in Table.
  • Standards Commercially-available native/labeled
    standards were obtained from CIL as authentic
    standard/mixtures for crosschecking the
    assignment. , 4-bromo- 3, 3, 4, 5-tetrachloro
    biphenyl was obtained from CIL for a PXB standard

Result and Discussion
Atropisomer in air and adipose tissue (HpCB)
Write a Comment
User Comments (0)
About PowerShow.com