Best available technology and modern waste incineration in Sundsvall Escobalt 12th december 2006 Anders Jonsson Sundsvall Energi - PowerPoint PPT Presentation

About This Presentation
Title:

Best available technology and modern waste incineration in Sundsvall Escobalt 12th december 2006 Anders Jonsson Sundsvall Energi

Description:

12 000 single family houses. 6 000 interested in DH? Expansion: 400 new ... BAT for Waste to energy. Ortviken Papermill. Korstaverket CHP plant. Tunadal Sawmill ... – PowerPoint PPT presentation

Number of Views:44
Avg rating:3.0/5.0
Slides: 21
Provided by: SEI48
Category:

less

Transcript and Presenter's Notes

Title: Best available technology and modern waste incineration in Sundsvall Escobalt 12th december 2006 Anders Jonsson Sundsvall Energi


1
Best available technology and modern waste
incineration in SundsvallEscobalt 12th december
2006Anders JonssonSundsvall Energi
2
(No Transcript)
3
Sundsvall Energi and the City group
4
Sundsvall Energi AB Group
5
Sundsvall Energi AB
District Heating 35 M Waste Treatment 9
M Electric Power 5 M Others 3 M
6
1969
2006
7
Environmental Certificate
8
District Heating system in Sundsvall600 GWh
9
District Heating Development
  • 12 000 single family houses
  • 6 000 interested in DH?
  • Expansion400 new clients/year

10
170 MW Combined Heat and Power plant, Oil
fired1981
Underground Storage of Oil 1977
60 MW Combined Heat and Power Plant Waste-fed 2006
600 GWh Heat 200 GWh Power
2 x 80 MW Oil fired heating plant 1978
CFB Waste 1984, 18 MW
  • Electric boiler,
  • 50 MW
  • 1984

11
Energymix Korstaverket
2005 (850 GWh)
2010 (1000 GWh)
HFO LS eq
Waste fuel Waste heat, Landfill- and digestergas
12
Regional Waste to Energy market
13
(No Transcript)
14
New Heat and Power Plant
  • Waste Capacity 60 MW
  • Combustion rate 20-25 tonnes/hour
  • Waste flow 200 000 tonnes/year
  • Investment approx 98 Million
  • Incinerator
  • Supplier Babcock Wilcox Völund
  • Flue gas cleaning
  • Supplier LAB Group SA
  • Turbine
  • Supplier Siemens
  • Groundworks Skanska
  • Building NCC

15
Strategic choisesCombined Heat and Power Plant
  • High rate of electric power
  • Low rate of flyash and solid residues
  • Washing of flyash and sludge
  • SCR reduction of NOx and dioxins
  • Waste reception 12 months/year

16
BAT for Waste to energy
17
(No Transcript)
18
Private Public Partnership solution
Tunadal Sawmill
Ortviken Papermill
Korstaverket CHP plant
19
Private Public Partnership solution
Korstaverket CHP plant - new wasteincinerator
green heat and power
Ortviken Papermill - wasteheat from fluegases to
DH
New turbine
40 MW 100-170 GWh/year
Heat 600 GWh/year
80-140 GWh/year
Tunadal Sawmill
20
Thank you for your attention!You can contact
me by e-mailanders.jonsson_at_serva.se
Write a Comment
User Comments (0)
About PowerShow.com