Review of Fuel Tank Flammability at Altitude Work
  • International Aircraft Systems Fire Protection
    Working Group
  • December 11, 2000

2
Goals
  • To determine the oxygen concentration needed to
    fully inert a fuel tank at different altitudes
  • To quantify the difference in severity of the
    fuel tank ignitions, both at altitude and reduced
    oxygen concentration

3
Experimental Apparatus
  • 9 ft3 fuel tank placed within 10 m3 pressure
    chamber
  • Heater placed on bottom of tank
  • Vacuum pump used to evacuate chamber to simulate
    desired altitude
  • 13 thermocouples fuel, ullage, walls floor
  • Dynamic Pressure Transducer (piezoelectric)
  • Analyzers HC (2 ports) O2

4
(No Transcript)
5
Test Program
  • Preliminary Methane Tests
  • Determine LFL of Methane at Sea Level and compare
    to numbers cited in literature
  • Determine oxygen concentration needed to fully
    inert a fuel tank at
  • Altitudes ranging from
  • 0 40 kft
  • corresponding temps
  • Several different mass
  • loadings FARs

6
Results to Date
  • Preliminary Methane Tests
  • LFL determined to be 5.3 compared to 5.2 cited
    in references
  • Sea Level Jet-A Tests
  • Mass loading of 4.45 kg/m3 liquid fuel
    temperature of 150F
  • O2 concentration of 12 to 12.5 needed to fully
    inert
  • No pressure readings obtained

7
Recent Progress
  • Installed new AMKO Systems, Inc. HC analyzer
  • Received dynamic pressure transducer from PCB
    Piezotronics
  • Resolved noise and data acquisition software
    issues

8
Future Plans
  • Replicate sea level tests with pressure
    instrumentation installed and new HC analyzer
  • Continue on with altitude tests
  • Please forward all comments questions to
  • Steven.Summer_at_tc.faa.gov