  • Cooldown 1 Test of vacuum, infrastructure, CTI,
    MAP (60 20K). Measurement of COP movement.

2
Cooldown 1 - Data
  • Successes
  • specification temperatures met
  • data logging went very well
  • alignment OK when cold
  • infrastructure gremlins mastered
  • timing lessons learnt
  • Problems
  • Daikin chiller trip (overload) took 24 hrs to
    resolve
  • LN2 fill
  • went OK but was not completed (because of time on
    other faults)
  • adds about 18-24hrs to cool down time
  • LN valved off with Bunsen valves as pop-offs
    delivered late. One valve leaked...
  • liquified air in LN tank and then ice-plugged
  • slowed cooldown and warm up
  • pop-off valves now fitted
  • Alignment change on warm up of one mirror
  • investigating