DTL RF coupling port design at LPSC
  • Emmanuelle Vernay, Denis Marchand, D Bondoux
  • Presented by JM De Conto
  • SERM_HIPPI_NC_XX16.doc (in preparation)
  • Goals
  • RF design done by PE Bernaudin
  • Thermal and mechanical studies done at LPSC
  • Decision can now be taken
  • Finalized, allows tank design (Russia)
  • Minor points (helicoflex joints/thickness versus
    strengtheners)

2
Rough view of the complexity
3
Hypothesis for thermal calculations
  • Températures in C
  • Température of water 25C, velocity 2m/s
  • Température fixed at limits (tank and guide )
    T25C
  • cooling pipes F 10mm
  • Conductivity stainless steel 16.3W.K-1.m-1,
  • 15 duty cycle
  • Studies also made for copper (not presented)
  • Transient (continuous vs not continuous) studies
    done (no difference)

4
Connecting guide cooling
5
Connecting guide / Temperatures von Mises
constraints
  • 15 duty cycle.
  • Power towards the DTL 44W
  • Power absorbed by the 3 cooling pipes 255W
  • ?T  0.07C for water
  • Constraints lt100 MPa

inner face
outer face
Steel thickness 6mmBoundary conditions 25 deg
C?T max 27 deg.?P0.2 Bar
6
Wave guide not a problem
Exchange with cooling fluid with tube 1  110
W With the 3 tubes in the central part of the
waveguide   53W
7
displacements
8
(No Transcript)
9
(No Transcript)
10
(No Transcript)
11
Conclusion
  • Tuning
  • At low level
  • RF guide will be cut at the right length before
    soldering
  • Cooling of the wave guide is not an issue
  • Deformation is not an issue
  • Temperature increase acceptable for DTL
  • Cooling seems to be feasible
  • Few room for the connecting guide cooling
  • Power exchange calculated
  • Data transmitted to the tank team
  • Interface the flange
  • Connecting guide part of the tank
  • Below part of the waveguide
  • Ready to be launched