Lag Correlator Testing
  • Aria Meyhoefer
  • Carnegie Mellon University
  • Summer 2001

2
The Lag Correlator
  • What it is
  • How it works
  • What I did with it
  • Reflections
  • Transmissions
  • Signal Response
  • Conclusions

3
17 Unit Lag Correlator
Inductor
Diode Array
Capacitor
Balun
4
How It Works
  • Antennas read signals off the sky with path
    difference depending on source angle
  • Signals travel along paths of equal length to
    Correlator
  • Inside correlator delay lines remove signal path
    delays
  • Each element of mixer array in the correlator
    measures the power from a particular direction
  • The correlator also allows measurement of the
    spectrum of any signal detected

5
Testing the Correlator
  • Signal Response Test
  • Send same signal into both inputs of correlator
  • Use different path lengths to create interference
  • Read response from oscilloscope
  • Reflections Test
  • Send signal into correlator through directional
    coupler
  • Terminate other input and output
  • Power reflects back though directional coupler to
    oscilloscope
  • Transmissions Test
  • Send a signal into one input of correlator
  • Read signal from other input of correlator
  • Find attenuation of correlator

Same microwave signal of 9dBm from 0.01 to 26.5
GHz was always used
6
  • Compared to mixer results
  • Expected Response One part in 158
  • Measured Response One part in 6000
  • Correlator is only 2.6 effective

7
Reflections Results
  • Left input reflects 21 of the power
  • Right input reflects 16 of the power

8
Transmission Results
  • 0.03 mV from right to left
  • 0.02 mV from left to right
  • Sweep generator outputting 0.4 V
  • Average attenuation of about 42 dB

9
Summary
  • Correlator Response only 2.6
  • Correlator Reflects about 18.5 power
  • Attenuation of 42 dB