Title: PLATON, A Multipurpose Crystallographic Tool
1PLATON, A Multipurpose Crystallographic Tool
- Ton Spek,
- National Single Crystal Service Facility,
- Utrecht, The Netherlands.
2What is PLATON
- A Multipurpose Crystallographic Tool.
- A Program Developed in, and Addressing the needs
of, a Single Crystal Service Environment. - Compatible with and Complementary to the Public
Domain SHELX Bruker-AXS SHELXTL Software.
(.res,.hkl,.cif,.fcf) - Semi Public domain (I.e. free-of-charge for
academics, but with a License Fee for For Profit
Organizations). - Developed on UNIX/LINUX and available on
MS-Windows MAC-OSX Platforms.
3Multipurpose Crystallographic Tool
- Automatic Geometry Analysis Listing.
- Molecular Graphics (ORTEP, PLUTON, Contour)
- Absorption Correction Tools(MULABS,TOMPA)
- ADDSYM - Check for Missed Symmetry.
- SQUEEZE Disordered Solvent Handling.
- Generation of Powder Patterns (Coordinates, hkl)
- Structure Validation (part of IUCr CHECKCIF).
- Analysis of Fo/Fc data including Bijvoet Pairs.
- Analysis of (Pseudo) Merohedral Twinning.
- System-S, Automated Structure Determination.
4EXAMPLE
- Input Shelx Style sucrose.res
- Alternatively
- .cif, .pdb, .fdat, .spf style files
- Invoke PLATON
- UNIX platon sucrose.res
- MS-Windows via Farrugia task menu
- Opening Menu (4 areas) ?
5(No Transcript)
6EXAMPLE
- Input Shelx Style sucrose.res
- (Alternatively .cif,.pdb,.dat,.spf style)
- Automatic ORTEP style PLOT ?
7(No Transcript)
8(No Transcript)
9EXAMPLE
- Input Shelx Style sucrose.res
- (Alternatively .cif,.pdb,.dat,.spf style)
- Automatic PLUTON style PLOT ?
10(No Transcript)
11EXAMPLE
- Input Shelx Style sucrose.res
- (Alternatively .cif,.pdb,.dat,.spf style)
- NEWMAN Plots ?
12(No Transcript)
13EXAMPLE
- Input Shelx Style sucrose.res
- (Alternatively .cif,.pdb,.dat,.spf style)
- Simulated Powder Pattern (hkl or coord)
- from coordinates ?
14(No Transcript)
15Intra-molecular Geometry
- Atom list sort.
- Detection of residues (connected set) and
derivation of the Moiety formula, Z and Z. - Bond distances, Bond Angles, Torsion Angles.
- Automatic ring search,automatic seach of planar
parts in the structure
16Intra-Molecular (Continued)
- Determination of the hybridization, R/S
assignments and topology numbers. - Listing of the plane-plane and bond-plane
angles. - Ring puckering analysis (Cremer Pople)
- Example ?
17(No Transcript)
18Inter-Molecular
- Hydrogen Bonds (linear, bi- and trifurcated)
- Automatic analysis in terms of 1, 2 and 3-D
networks (aggregates or cooperative) - Search for pi-pi and C-H..pi interactions
- Example H-Bond Table ?
19(No Transcript)
20CALC ALL GEOMETRY LISTING
- With CALC ALL an exhaustive listing of derived
intra-, inter- and coordination geometry etc. is
produced, including a structure validation
report. - Two content identical files are produced.
.lis and lps. The first is lineprinter style,
the latter is suitable for either a PostScript
printer or inspection with ghostview. - We routinely provide this exhaustive listing to
the chemist/client along with an ORTEP.
21PLATON/ADDSYM ANALYSIS
- Example of a missed symmetry case from the CSD ?
22 BAMYEU Dalton Trans 2003,134-140 Cc
23(No Transcript)
24(No Transcript)
25NEWSYM
- Companion to ADDSYM Analysis
- Structure factors calculated from current cell,
symmetry and coordinate info. - Determination of the Space Group from the
systematic absences in F(calc) - Extinctions in F(calc) may differ from those in
F(obs) due to poor data.
26(No Transcript)
27(No Transcript)
28QUATERNION FIT
- In many cases, an automatic molecule fit can be
performed - A) Identical atom numbering
- B) Sufficient Unique Atoms
- C) Manual picking of a few atom pairs
29(No Transcript)
30QUATERNION FIT
31Cg1 0.946 0.234 0.592 Cg2 0.441 0.253 0.581
32(No Transcript)
33(No Transcript)
34STRUCTURE VALIDATION
- Single crystal structure validation addresses
three important questions - 1 Is the reported information complete?
- 2 What is the quality of the analysis?
- 3 Is the Structure Correct?
35IUCR-CHECKCIF
- IUCR-TESTS
- MISSING DATA, PROPER PROCEDURE, QUALITY
- PLATON TESTS
- SYMMETRY, GEOMETRY, DISPLACEMENT PARAMETERS
- ALERT LEVELS
- ALERT A - SERIOUS PROBLEM
- ALERT B - POTENTIALLY SERIOUS PROBLEM
- ALERT C - CHECK EXPLAIN
36Problems Addressed by PLATON
- Missed Higher Space Group Symmetry
- Solvent Accessible Voids in the Structure
- Unusual Displacement Parameters
- Hirshfeld Rigid Bond test
- Miss-assigned Atom Type
- Population/Occupancy Parameters
- Mono Coordinated/Bonded Metals
- Isolated Atoms
37Problems Addressed by PLATON
- Too Many Hydrogen Atoms on an Atom
- Missing Hydrogen Atoms
- Valence Hybridization
- Short Intra/Inter-Molecular Contacts
- O-H without Acceptor
- Unusual Bond Length/Angle
- CH3 Moiety Geometry
38Validation with PLATON
- - Details www.cryst.chem.uu.nl/platon
- Driven by the file CHECK.DEF with criteria, ALERT
messages and advice. - Button VALIDATION on PLATON MAIN Menu
- Use platon u structure.cif
- Result on file structure.chk
- Applicable on CIFs and CCDC-FDAT
- FCF-Valid platon V structure.cif
39Example of Misplaced Hydrogen Atom
40Two ALERTS related to the misplaced Hydrogen Atom
41Unsatisfactory Hydrogen Bond Network
42(No Transcript)
43(No Transcript)
44Satisfactory Hydrogen Bond Network with new
H-position
45(No Transcript)
46Solvent Accessible Voids
- A typical crystal structure has only 65 of the
available space filled. - The remainder volume is in voids in-between atoms
(to small to accommodate an H-atom) - Solvent accessible voids are defined as regions
in the structure that can accommodate at least a
sphere with radius 1.2 Angstrom without
intersecting with any of the van der Waals
spheres assigned to each atom in the structure.
47DEFINE SOLVENT ACCESSIBLE VOID
STEP 1 EXCLUDE VOLUME INSIDE THE VAN DER
WAALS SPHERE
48DEFINE SOLVENT ACCESSIBLE VOID
STEP 2 EXCLUDE AN ACCESS RADIAL VOLUME TO
FIND THE LOCATION OF ATOMS WITH THEIR CENTRE AT
LEAST 1.2 ANGSTROM AWAY
49DEFINE SOLVENT ACCESSIBLE VOID
STEP 3 EXTEND INNER VOLUME WITH POINTS
WITHIN 1.2 ANGSTROM FROM ITS OUTER BOUNDS
50Cg
51(No Transcript)
52SQUEEZE
- Takes the contribution of disordered solvents
into account by back-Fourier transformation of
density found in the solvent accessible volume
outside the ordered part of the structure. - Filter Input shelxl.res shelxl.hkl
- Output solvent free shelxl.hkl
53SQUEEZE PROCEDURE
- Refine structure including H-atoms
- Use .res and .hkl for the SQUEEZE calculation
- Continue refinement using the reflection file
produced by SQUEEZE - Calculate a final .fcf using the latest .res and
.hkl (from SQUEEZE) using PLATON/FCF - Append the .fsq file to the final .cif for
publication.
54Twinning
- Twinning results in overlap of reflections with
different hkl - Twinning can be detected during the data
collection experiment - Cases of (Pseudo) Merohedral twinning are
generally detected during the structure
determination
55(Pseudo)Merohedral Twinning
- Options to handle twinning in L.S. refinement
available in SHELXL, CRYSTALS etc. - Problem Determination of the Twin Law that is in
effect. - Partial solution coset decomposition, try all
possibilities - (I.e. all symmetry operations of the lattice
but not of the structure) - ROTAX (S.Parson et al. (2002) J. Appl. Cryst.,
35, 168. - (Based on the analysis of poorly fitting
reflections of the type F(obs) gtgt F(calc) ) - TwinRotMat Automatic Twinning Analysis as
implemented in PLATON (Based on a similar
analysis but implemented differently)
56Example
- Structure refined to R 20 in P-3
- Run TwinRotMat on CIF/FCF
- Result Twinlaw with estimate of the twinning
fraction and drop in R-value
57(No Transcript)
58(No Transcript)
59Absolute Structure
- The absolute structure of a compound is normally
determined with the refinement of the Flack
parameter. - The value of the Flack parameter can be
inconclusive in view of a high su. - A detailed scatter-plot may be more conclusive.
60BIJVOET PAIR SCATTER PLOT
61System S
- Automatic structure determination
- (Space group determination, solution,
refinement, analysis) - Build-in in PLATON (Unix only)
- Calls external programs including itself for
various functions. - Program runs in either guided or
no-questions-asked mode
62SYSTEM S
- INPUT HKL, CELL CONTENT data
- Interface to SHELX(S/L), DIRDIF,SIR97, SIR2002,
POVRAY,RASTER3D etc. - Internal PLATON Tools Space Group Det,
Absorption Correction, Graphics, Validation,
ADDSYM etc. - Platon s compound.ins nqa
63Finally
- Other features
- Structure Tidy (CIF input)
- Bond Valence
- Renaming of atoms, cif2res, asym-view
- More Info
- www.cryst.chem.uu.nl/platon
- Right mouse clicks gt help on menu item
64Thanks
- Thanks to the users for their
- Complaints
- Bug reports (undocumented features ..)
- Suggestions
- And you for your attention
65(No Transcript)