Results Post Processing using MSC.Acumen
  • Francis BARREAU - Snecma Moteurs
  • Antoine SOEIRO - MSC.Software

2
Acumen Résultats
  • It is an application developed by MSC.Software
    for Snecma Moteurs.
  • It is developed using MSC.Acumen.
  • It allows post processing of the results
    calculated by Samcef (main mechanical analysis
    program at Snecma Moteurs).

3
Why Acumen Résultats ?
  • Post processing with Patran
  • is adapted for all type of results,
  • allows a great variety of displays.
  • But
  • It remains complicated to use, especially for an
    inexperienced user.
  • It is not easy to automate some displays.
  • It is missing some essential functions like units
    management.
  • It allows to obtain different values depending on
    the options chosen. Which value is the right one ?

4
Why Acumen Résultats ?
  • Acumen Résultats allows
  • To display results calculated with Samcef.
  • Simplification of post processing tasks by
    offering an easy-to-understand Graphic user
    interface even for an inexperienced user.
  • Display of results in a reliable manner to get
    only the right values.
  • Automatic chaining of different Patran commands
    to get a complex display.
  • Automation of some post processing.
  • Addition of some missing functions (managing
    units) or improvement of existing ones ( titles,
    XY plots).

5
Acumen Résultats menus
  • Main buttons.
  • The different steps of post processing.
  • Selection area.
  • Input area.
  • To go to the next or the previous step.

Icons box.
6
Step 1 to get the finite element model.
  • Wizard like user interface.
  • Acumen start.
  • User identification.
  • Selection of the MSC.Patran database.
  • Finite element model definition.
  • Immediate start of post processing or loading of
    Samcef Results.
  • Other choices
  • Units used for calculation.
  • Units for display.
  • Language for the titles.
  • Make use of the HTML report.

7
Steps 2 and 3 utilities functions.
  • Step 2 managing the model.
  • Managing groups and lists to display results on a
    part of the model.
  • Managing the coordinate systems used to display
    results.
  • Managing the viewport.
  • Step 3 managing results.
  • To rename or delete existing results.
  • To create new results by linear combination.
  • To create new results by calculating the maximum,
    the minimum, the average of a set of existing
    results.

8
Step 4 displaying results.
To guide the user in order to get the display.
9
Step 4 displaying results.
  • Only to allow options that correspond to the
    finite element model, the result quantity and the
    display. Examples
  • To display 2D tensors only for 2D models.
  • To display a deformed plot only for displacement
    results. To display a vector plot for all types
    of vector results (displacement, loads, ).
  • To display the results on the top, middle and
    bottom surface only for shell models.

10
Step 4 displaying results.
  • To automatically select the Samcef result code
    number which correspond to the result quantity to
    display. Example
  • Shell model.
  • Stress display.
  • Average stress at the center of the elements.
  • Top surface stresses.
  • Von Mises stresses.
  • Result  Code number  Samcef 3431.

11
Step 4 displaying results.
  • To propose simple choices for the element results
    display
  • To display the average value at the center of the
    elements.
  • To display an extrapolated value at the element
    nodes
  • With discontinuities at the nodes.
  • With an average at the nodes.
  • With the largest difference of the values at the
    same node this will help the user to check the
    quality of his calculation.
  • Example for the average value at the center of
    the elements MSC.Patran / Results equivalent
    options

12
Step 4 displaying results.
  • To merge a set of different Patran commands into
    one Acumen display. Examples
  • Image captures with an automatic switch between
    black and white background colors.
  • XY Plots with automatic scaling and titles.
  • Stress tensors having traction values with a red
    arrow and compression values with a blue arrow.

13
Step 4 XY plots
  • Automatic titles.
  • Element, component, local coordinate system used.
  • Automatic axis title result displayed, units.
  • Automatic axis scales with whole values.
  • Automatic curve color and style.

14
Step 4 tensor display.
  • Patran
  • Results Create / Marker / Tensor.
  • Results Select Result Case(s).
  • Results Select Tensor Result  Code 3411 .
  • Results Show As  Principal .
  • Results Show as Spectrum.
  • Spectrum Create 3 colors black, red, blue.
  • Results Show Tensor Box scale 0.0.
  • Results No tensor Label
  • Results Average Domain None.
  • Results Average Method Average / Derive.
  • Results Extrapolation Shape fn.
  • Results Apply.
  • Ranges create 2 values.
  • Ranges Fit results and Calculate.
  • Ranges From/To 0.0 for intermediate values.
  • Ranges Apply.
  • Ranges Assign Target Range to Viewport.
  • Set Range don t overwrite range values.
  • Acumen résultats
  • Spatial post processing.
  • Result selection.
  • Stress display.
  • On 2D elements.
  • Average stress at the center of elements.
  • Tensor display.
  • Display options no label.

15
Step 4 displaying results.
  • To display results in reliable manner to show
    only the relevant values.
  • Example fringe plots of von Mises stresses at
    the center of the elements. Maximum value
    displayed
  • Patran
  • 2  codes résultats  Samcef available (3411 ou
    3310) x 2  Averaging Domain  ( None  ou
     All ) at least 4 different maximum values
    can be displayed.
  • Acumen Résultats
  • Automatic selection of Samcef  result code 
    3411 and automatic choice of the display options
    one maximum value is displayed in accordance
    with Snecma Moteurs post processing methods.

16
Step 5 reproducing results.
  • To automatically reproduce the current display on
    other results
  • Superimposed plots of deformation and stress
    fringe.
  • Image and animation capture.
  • To repeat the current display with different
    result units or title language.
  • To insert the current display into an HTLM report.

17
Step 5 reproducing results.
  • Example modal calculation with stresses.
  • Goal to display the deformation and the von
    Mises stress fringe for all the modes and to
    capture all these images.
  • First part step 4 create this display for the
    first mode.
  • Second part step 5 reproduce this display
  • Possible change of the units.
  • Select the modes to display.
  • Validate Acumen does the plot and capture for
    all the selected modes.

18
HTML report.
  • Description of the model.
  • Description of all the modifications of the
    results.
  • Automatic insertion of all the graphic outputs.

19
Conclusion
  • MSC.Acumen has allowed us to create a new
    application for post processing Samcef results.
  • At least, 95 of Snecma Moteurs needs are
    fulfilled.
  • Post processing is now simpler, more reliable and
    can be automated.
  • A new application for defining Element
    properties, loads and boundary conditions for
    Samcef calculations is being developed by Snecma
    Moteurs and MSC.Software.