SmartBridge Control Group - PowerPoint PPT Presentation

1 / 9
About This Presentation
Title:

SmartBridge Control Group

Description:

Layers configured based on history, current conditions. Mesonet Weather Station Integration ... Radar-based Weather Front Prediction. Locate front and project ... – PowerPoint PPT presentation

Number of Views:213
Avg rating:3.0/5.0
Slides: 10
Provided by: brianca93
Category:

less

Transcript and Presenter's Notes

Title: SmartBridge Control Group


1
SmartBridge Control Group
  • Outline
  • Current Functionality
  • Working Control System Simulator
  • Control System Overview
  • Mesonet Weather Station Integration
  • Interface to HVACSIM Bridge Model
  • Layered Control Concept
  • Simulation
  • Current Tasks

2
Control System Overview
Objective - No Ice on Bridge!
3
Layered Control Concept
  • Multiple Independent Feedforward Controllers
  • Parallel operation
  • Worst case scenario rules
  • Dynamic Layer Configurations
  • Cold weather usually moves NW to SE (in OK)
  • Additional layers added to catch unusual weather
  • Layers configured based on history, current
    conditions

4
Mesonet Weather Station Integration
  • Archived Data for 1993-1999
  • Ten stations
  • 15-minute data

5
Mesonet Weather Sites
6
HVACSIM Model Integration
  • Bridge Response Time
  • Iterative with HVACSIM model
  • Utilizes Mesonet Weather Data
  • On/Off Heat Pump Response
  • 33.5oF target average bridge deck temperature
  • No Ice on Bridge - Conservative Approach

7
Simulation
  • Use archived weather data and HVACSIM
  • 60 sec. computer time per run
  • Controller - 5 sec.
  • HVACSIM Model - 15 to 75 sec.
  • 60 hrs. computer time per winter
  • System evaluation
  • Bridge on-time
  • Ground loop temperatures

8
Current Tasks
  • NWS Weather Station Integration
  • Use to validate, enhance Mesonet data
  • Radar-based Weather Front Prediction
  • Locate front and project path, speed
  • Rough estimate of precipitation
  • Bridge Model Enhancements
  • Variable Flow Rate
  • Evaluate Other Bridge Systems
  • Virginia / Oregon

9
Tunable User Parameters
  • Parameters
  • Danger Temp
  • Minimum desired average bridge deck temp.
  • Approach Temp
  • Weather station warning temperature
  • Warn Time
  • Length of time future weather is extrapolated
  • Layer Threshold
  • of warnings required to start heat pump