Title: MATERIALS IN HIDDEN AREAS
1MATERIALS IN HIDDEN AREAS
- RADIANT PANEL TEST RESULTS
2MATERIALS IN HIDDEN AREAS
- 1-MATERIALS CURRENTLY USED IN COCKPIT AND CABIN
- TWO THERMOPLASTICS
- LAMINATED PANEL GLASS/PHENOLIC-2PLIES
- SANDWICH PANEL NIDA NOMEX 4 PLIES GLASS/PHENOLIC
3MATERIALS IN HIDDEN AREAS
- 2- Combination of an insulation blanket film pvf
30 wires bundled with attachment clamps made of
polyamide - the attachment clamps meet the requirements of
the vertical bunsen burner test 12 seconds
4MATERIALS IN HIDDEN AREAS
RADIANT PANEL STANDARD TEST METHOD
SIZE OF THE SPECIMEN 15x 12 cm
5MATERIALS IN HIDDEN AREAS
SIZE OF THE SPECIMEN 50 X 17, 5 cm
6MATERIALS IN HIDDEN AREAS
- TESTS ON WIRES ATTACHMENT CLAMPS INSULATION
BLANKETS
FIRST RESULTS
A LOT OF DISPERSION
-14 or 30 wires bundled located on blanket
with 2, 3 or 4 clamps separated at 2 to 5 cm -
clamps melted after removing the pilot burner -
The flame remains or not afterwards.
7MATERIALS IN HIDDEN AREAS
- In some hidden parts the space out between two
attachment clamps is less than 1,5 cm - scenario 30 wires bundled 5 clamps separated
every 1 cm and located on the insulation blanket
8MATERIALS IN HIDDEN AREAS
BEFORE THE TEST AFTER THE TEST
9MATERIALS IN HIDDEN AREAS
During the test, the burner removed
10MATERIALS IN HIDDEN AREAS
- 3 tests carried out
- film melted
- cable ties melted and flames remained after
removing the pilot burner - test 1 after flame time 6 minutes 53 secondes
- test 2 after flame time 4 minutes 32 secondes
- test 3 after flame time 6 minutes 35 secondes