Title: BigBite Wire Chamber Test


1
BigBite Wire Chamber Test
Wire chamber
Shower system
Optics Slot-slit
  • Xin Qian
  • Duke University
  • Feb 20th
  • For TRANSVERSITY
  • Collaboration

Scintillator
Gas Cerenkov
Magnetic field shielding
2
Trigger for cosmic test
Front scintillator
Back scintillator
Computers,CODA
Forming Logic AND
cable
OR
VME
3
Wire Chamber
Low Voltage
HV for wire chamber
Threshold
4
Signal Output of Wire Chamber
Signal from cards
Level shifter cards
Long flat cable
VME
FASTBUS
5
Number_of_hits vs wire number
Reference channel
  • Flat structure suggests no local problems except
    two broken cables.
  • The structure of the hits pattern is due to the
    trigger setup.

Two bad cables
6
Drift time for the first time
  • See a clear drift time
  • Most of T2 is out of T1 main peak.
  • T1 is the time for first hit on this channel
    (wire)
  • T2 is the time for the second hit on this channel.

t1
t2
7
Second hit
  • 10 T2
  • Normal

8
Problems
  • Everything looks normal, except the number of
    hits. (First noticed by Xiaodong)
  • For run 249, we have about 10k trigger, number
    of hits on first plane is about 50k.
  • Several possible reasons
  • Threshold is too low
  • High voltage is too high
  • Ground problems?
  • Other reason?

Big tail
RUN 249 X axis Number of hits per event
9
Threshold Change
  • Did not see clear change in slope.

Lower threshold
Higher threshold
10
Threshold Change
  • No clear change in drift time plot

Low Threshld
High Threshld
11
Threshold Change
Lower threshold
  • Fewer second hit with higher threshold.

Higher threshold
12
Threshold Change
Lower threshold
  • No clear change in correlation.

Higher threshold
13
Event Display
  • See Xins webpage
  • http//www.jlab.org/xqian/TRANSVERSITY/testlab/in
    dex.html
  • HV is too high is ruled out.

14
Conclusion
  • Data was taken for first wire chamber using
    front and back scintillator coincident trigger.
  • Data was recored using VME TDC.
  • Drift time hitting pattern suggest no local
    problems.
  • Do see a problem with more hits than expected.
    (Not a VME problem, see the same thing on
    FASTBUS)
  • Rule out threshold, HV or any local problems.
  • Reason is not clear at this stage
  • Ground issue?
  • Flat cable?
  • Need experts suggestions.

15