A PRESENTATION FROM RIO-GOH CHENNAI
2
A COMPARATIVE ANALYSIS OF VARIOUS AUTOMATED
PERIMETERS
  • Author Prof. Dr. V. Velayutham
  • Co-Authors Dr. D. Ranjit Prabhu
  • Dr. Nirmal Fredrick
  • Dr. Suma Elangovan

3
AIM
  • Comparison of visual field plotting in glaucoma
    patients with
  • Octopus Interzeag 1-2-3,
  • Humphrey Field Analyzer II and
  • Frequency Doubling Perimetry.

4
Design
  • Prospective, Comparative study
  • Participants
  • 100 eyes of 50 patients who attended glaucoma
    clinic in RIO-GOH during Jan 2005 and March 2006.
  • All patients were randomly selected

5
Inclusion Criteria
  • Primary open angle glaucoma, Normo-tensive
    glaucoma and Glaucoma suspect
  • Best corrected visual acuity 6/12 or better
  • Gonio open angle ( gt2 by Shaffers Grading)
  • Patients co-operative for visual field analysis

6
Exclusion Criteria
  • Closed angles by gonioscopy
  • Secondary and Congenital glaucoma
  • Ocular diseases showing similar visual field
    defects
  • Patients with media opacities - corneal edema /
    opacity, lens changes and retinal pathology
  • Patients who underwent intraocular surgeries or
    laser treatment

7
Patient Evaluation
  • Slit Lamp Examination
  • Measurement of Intraocular pressure
  • Slit Lamp Biomicroscopy Fundus
  • Gonioscopy Angle Grading

8
Visual Field Examinations
  • Octopus Interzeag 1-2-3 TOP
  • Humphrey Field Analyzer II, central 30-2
    threshold test (SITA standard)
  • Frequency Doubling Technology Full threshold
    (C-20)
  • All tests were carried out within a period of one
    week by trained personnel.

9
Parameters Analysed
  • Mean Deviation / Mean Defect and Pattern Standard
    deviation / Loss variance of both eyes were
    compared and correlated between these perimeters
    using the Pearson correlation and Scatter diagram
    with regression estimate
  • Linear regression analysis was used to calculate
    the correlation coefficients.
  • Statistical comparison between groups used
    unpaired 2-tailed-t-test.
  • The average time taken to perform each test was
    analysed

10
Correlation of Mean Deviation / Defects between
the perimeters
RE
LE
  • O-MD vs H-MD r -0.520, plt0.001
  • O-MD vs F-MD r -0.723, plt0.001
  • H-MD vs F-MD r 0.628, plt0.001
  • O-MD vs H-MD r -0.581, plt0.001
  • O-MD vs F-MD r -0.648, plt0.001
  • H-MD vs F-MD r 0.683, plt0.001

11
Correlation of Pattern Standard Deviation / Loss
Variance between the perimeters
RE
LE
  • O-LV vs H-PSD r 0.312, plt0.002
  • O-LV vs F-PSD r 0.283, plt0.05
  • H-PSD vs F-PSD r 0.427, plt0.002
  • O-LV vs H-PSD r 0.544, plt0.001
  • O-LV vs F-PSD r 0.568, plt0.001
  • H-PSD vs F-PSD r 0.650, plt0.001

12
Time Duration taken to perform the test
13
Discussion
  • Octopus Mean Defects
  • negatively correlates with Humphrey and FDT
  • Humphrey Mean Deviation
  • positively correlates with FDT
  • P lt 0.001 statistically significant
  • Octopus Loss Variance
  • positively correlates with PSD of Humphrey and
    FDT
  • Humphrey PSD
  • positively correlates with FDT
  • RE p lt 0.05 LE p lt 0.001 --- correlation
    statistically significant
  • Test duration least in Octopus

14
Summarizing
  • Visual field plotting with Octopus (TOP) is
    shortest
  • Global indices arrived at field plotting with all
    three perimeters are comparable

15