Title: The AlwaysOn Roof Monitoring and Leak Detection Systems


1
The Always-On Roof Monitoring and Leak
Detection Systems
from
2
  • North American Partner of
  • German-based manufacturer
  • Primary patent holder and developer of leak
    monitoring and detection products

3
SMARTEX ROOF MONITORING AND LEAK LOCATION SYSTEMS
  • Green roofs
  • Plaza Decks
  • Solar roofs
  • Sloped or Flat roofs
  • Waterproofing

4
  • Material compatibility with the SMARTEX system
  • Progeo checks all roofing and waterproofing
    membranes proposed to be used over the SMARTEX
    system so that there are no conductivity issues.
    To date, certain PVC and EPDM membranes cannot be
    used, as they produce false positive signals for
    leakage. Check with us to get the latest
    information on these compatibilities.

5
OBVIOUS STRUCTURAL DAMAGE FROM LEAKS
6
NOT-SO-OBVIOUS STRUCTURAL DAMAGE FROM LEAKS
7
POTENTIAL STRUCTURAL DAMAGE FROM LEAKS
8
ELECTRICAL MEANS OF LEAK DETECTION AND LOCATION
MANUAL TESTING METHODS
ELECTRIC FIELD VECTOR MAPPING
SPARK TESTING
9
ELECTRICAL MEANS OF LEAK DETECTION AND LOCATION
  • CONTINUOUS TESTING

10
COMPONENTS OF SMARTEX LEAK MONITORING
AND LOCATION SYSTEM
11
COMPONENT 1
TYPICAL SENSOR AND CABLE FOR COLD APPLICATIONS
(ELASTOMERIC ROOFING). ALL SENSOR AND CABLE
ASSEMBLIES ARE PREFABRICATED FOR EACH
INDIVIDUAL PROJECT
12
COMPONENT 1A TYPICAL SENSOR CABLE FOR HOT
APPLICATIONS (BOTH MOPPED AND ROLLED BITUMINOUS
MEMBRANES)
13
COMPONENT 2 CONDUCTIVE FELT IS APPLIED OVER
THE SENSOR GRID
14
COMPONENT 3 INJECTOR ELECTRODE PLACED ON TOP
OF THE MEMBRANE SYSTEM TO GENERATE THE TEST
SIGNAL OVER THE SURFACE OF THE MEMBRANE.
15
TYPICAL SMARTEX SENSOR LAYOUT PLAN VIEW
16
SENSOR GRID LAYOUT ON BUILDING PLAN
17
TYPICAL CONSTRUCTION SMARTEX DIRECTLY UNDER THE
MEMBRANE
18
TYPICAL CONSTRUCTION SMARTEX AT PARAPET
19
  • SMARTEX
  • INSTALLATION

20
LOCATE AND SECURE ALL SENSORS IN GRID ACCORDING
TO PLAN
21
TAPE OR FASTEN SENSORS TO DECK, INSULATION OR
OTHER NON-CONDUCTIVE SUBSTRATE
22
SMARTEX CAN BE APPLIED TO SLOPING DECKS
23
OVERLAY SENSORS WITH CONDUCTIVE FELT
24
USE NON-CONDUCTIVE FASTENER ASSEMBLIES WHEN IN
CONTACT WITH THE SMARTEX SYSTEM
25
INSULATED FASTENERS SECURE ROOFING TO DECK
THROUGH CONDUCTIVE FELT
26
ALL ROOF PENETRATIONS MUST BE INSULATED OR
NON-CONDUCTIVE
27
INSTALL ROOFING OVER SMARTEX ASSEMBLY (ELASTOMERIC
ROOFING)
28
MODIFIED BITUMINOUS ROOFING
29
SMARTEX APPLIED UNDER 2 PLY MODIFIED BITUMEN
SYSTEM
30
HAND TEST FOR CONDITION OF SENSORS
THE HAND TEST IDENTIFIES ANY DAMAGE TO THE CABLE
OR SENSOR AND LOCATES THE DAMAGE. THE CABLE IS
REPAIRED USING STANDARD ELECTRICAL
REPAIR TECHNIQUES.
31
SPLICE GRID CABLES
32
REPAIRED CABLE WILL GO BACK INTO SERVICE
33
INJECTOR ELECTRODE AND PENETRATION THROUGH
MEMBRANE
34
SENSOR AND INJECTOR CABLES CHASED FROM ROOF INTO
BUILDING INTERIOR
35
SMARTEX HUB AND EVALUATION CENTER
36
COMPUTER SCREEN OUTPUT OF ACTUAL LEAK OCCURANCE.
RED DOT IS THE LOCATION OF THE LEAK.
37
COMPUTER SCREEN OF ACTUAL LEAK OCCURANCE USING
COORDINATE METHOD. NOTE TIME OF OCCURANCE IS
RECORDED.
38
ACTUAL LOCATION OF LEAK ON THE DIOCESAN MUSEUM IN
COLOGNE, GERMANY
39
DIOCESAN MUSEUM, COLOGNE, GERMANY
40
LOCATING LEAKS WITHOUT SMARTEX
41
ACTUAL OCCURANCE OF A LEAK ON A COMPLICATED ROOF
OVER A HOSPITAL
42
HOSPITAL ROOF MULTIPLE LEAKS DETECTED SINCE
INSTALLATION IN 1999.
43
SMARTEX CANNOT PREVENT THIS ABUSE BUT IT CAN
DETECT THE DAMAGE THAT OCCURS
44
LOCATING A LEAK IN A ROOF COVERED BY SOIL OR
PLAZA MATERIALS WITHOUT SMARTEX
45
TOO EXPENSIVE TO LOCATE AND REPAIR THE LEAKS
NOWWED HAVE TO TEAR UP THE WHOLE THING.
46
Case Study BMW WORLD MUSEUM AND CENTER MUNICH,
GERMANY
47
SMARTEX SENSOR GRID LAYOUT BMW WORLD
48
BMW WORLD ROOF HALF FINISHED NOTE ALL MATERIALS
AND EQUIPMENT STILL ON THE FINISHED PART
49
  • ROOFING
  • CHALLENGES

50
SKYLIGHTS WITH MULTIPLE ANGLES AND GRADES
51
MULTIPLE PENETRATIONS
52
SOLAR PANELS
53
COORDINATION
54
RECIPES FOR DISASTER!
55
MATERIAL AND EQUIPMENT STORAGE ON UNPROTECTED
MEMBRANE
56
(MANY) OTHER TRADES WORKING OVER UNPROTECTED
MEMBRANE
57
THE FINAL CHALLENGE
ACCESSIBILITY (Once the membrane is covered, how
does one locate problems?)
58
PANELS IN SLOPING CONE AREA
59
SOLAR PANELS OVER MOST OF ROOF
60
MEASURES TAKEN TO ASSURE A QUALITY INSTALLATION
  • Full Time Inspection of Installation
  • Vacuum Check all Seams
  • Multiple Sweep and Inspect

61
RESULT OF ONE SMARTEX SCAN (150 LEAKS LATER)
62
8 More Leaks.
63
WHAT THE BMW WORLD PROJECT TEACHES US
  • Even with Top Quality installation and
    inspection, subsequent construction phase damage
    resulting in leakage can occur.
  • Locating leaks would have been the real challenge
    without SMARTEX.
  • Ensuring that future leaks from maintenance of
    all the structures on the roof (and other causes
    of membrane damage) are immediately identified
    and located IS the SMARTEX promise.

We Provide Confidence!