Chin and Malar Augmentation - PowerPoint PPT Presentation

1 / 31
About This Presentation
Title:

Chin and Malar Augmentation

Description:

Chin and Malar Augmentation. Ravi Pachigolla, MD. Karen Calhoun, ... Chin soft tissue pad thickness ... Chin Pad Thickness. Soft tissue thickness of 8 ... – PowerPoint PPT presentation

Number of Views:154
Avg rating:3.0/5.0
Slides: 32
Provided by: UTMB5
Category:

less

Transcript and Presenter's Notes

Title: Chin and Malar Augmentation


1
Chin and Malar Augmentation
  • Ravi Pachigolla, MD
  • Karen Calhoun, MD

2
Introduction
  • Chin augmentation
  • Malar augmentation
  • Chin augmentation more developed

3
Chin projection
  • Line perpendicular to the frankfurt horizontal at
    lower vermilion
  • Legan Angle
  • Merrifield Z angle
  • Gonzales-Ulloa
  • Line from lips to chin

4
Frankfurt horizontal line
5
Other methods of chin projection
6
Quick chin projection
7
Occlusal Relationship
  • Microgenia
  • Micrognathia
  • Retrognathia
  • Address occlusal problems first

8
Augmentation
  • Sagittal augmentation
  • Vertical augmentation secondary
  • Lateral augmentation tertiary

9
Lower lip analysis
  • Lower lip posterior to upper lip
  • Chin soft tissue pad thickness
  • Labiomental fold crucial
  • Caution in patients with high labiomental fold

10
Chin Pad Thickness
  • Soft tissue thickness of 8 to 11 mm normal
  • Avoid setting back jaws with thick pads
  • Attempts at setback leads to bony irregularities,
    soft tissue pad ptosis and an unsupported chin pad

11
Biomaterials
  • Silicone implants inert
  • Supramid - moderate foreign body reaction
  • Proplast type I and type II - harder to carve
  • ePTFE - less underlying bone resorption
  • Porous vs. nonporous implants

12
Surgical Techniques
  • Intraoral vs. extraoral
  • Placement of implant subperiosteally
  • Advantages and disadvantages
  • Center the implant
  • Closure in layers with pressure dressing for days
  • Placement on the pogonion

13
Pogonion Placement and sublabial filler
14
Chin Fixation
15
Complications
  • Technically easy
  • Size mismatch
  • Malpositioned implant
  • Removal of implant
  • Lip numbness

16
Malpositioned implant
17
Implant removal
18
Lip Numbness
19
Postoperative Result
20
(No Transcript)
21
Malar augmentation
  • Indications for augmentation
  • Aesthetics of the malar mound
  • More youthful appearance

22
Determination of malar eminence
23
(No Transcript)
24
Hinderers malar eminence
25
Powells eminence
26
Prendergast
27
Implant types
  • McGhan
  • Binder submalar
  • ePTFE
  • Porous polyethylene

28
Operative Techniques
  • Intraoral incision usually
  • Elevation over zygoma
  • Precise pocket
  • Fixation unnecessary

29
(No Transcript)
30
(No Transcript)
31
Complications
  • Malpositioned implant
  • Infection
  • Sizing most common complaint
  • Small audmentation can be performed with ePTFE
  • Silastic only used with sinus fracture
Write a Comment
User Comments (0)
About PowerShow.com