Transcript and Presenter's Notes

Title: Design Approach Review MDA Completion RPG Build 9'0


1
Design Approach ReviewMDA CompletionRPG Build
9.0
  • Brian Klein, RSIS
  • 13 October 2005

2
Contents
  • CCR..3
  • Concept of Operations..........4
  • Impacts to Top Level Architecture.................
    ......................5
  • Impacts to WSR-88D Architecture...6
  • MDA Data Flow..........................
    ..7
  • Design Approach ..................................
    ............................10
  • Products......................................
    .................12
  • Development Approach...14
  • Test Approach...15
  • Integration Challenges/Risks..16
  • Proposed Schedule..17
  • Action Items...18

3
CCR
  • CCR
  • NA05-23001 Complete Transition to the New
    Mesocyclone Detection Algorithm (Build 9.0)
  • RC-9375

4
Concept of Operations
  • Preparing to transition users to the exclusive
    use of MDA based Mesocyclone data
  • Alerting/UAM Product
  • Alert Timing End of Volume
  • Alert Threshold Values 1, 2, 3, 4, 5, 6
    (Strength Rank, AWIPS default value 5)
  • Default Paired Product MD (141).
  • Combined Attributes Table (CR/CZ, 35-38 CRE/CZE,
    95-98)
  • RCM Product (74)
  • Based on Minimum Display Filter Rank (default 5)
  • Begin central collection of MD product (141)
    after Build 8 deployment
  • Eventual removal of the legacy algorithm
    including the M and MRU products (proposed for
    Build 10)

5
Impacts to Top-Level Architecture
  • External Display Systems
  • AWIPS software may be affected by new alert
    category
  • Possible SCAN software modifications required if
    parsing of Combined Attributes Table or SCAN use
    of WSR-88D alerting functionality
  • Users of RCM, UAM, CR/CZ and CRE/CZE (only the
    Combined Attributes table) may be affected in
    Build 9
  • Users of M and MRU should plan to transition to
    MDA products (MD, DMD) prior to planned removal
    of legacy algorithm in Build 10.
  • Benefits
  • Remove redundant processing
  • Remove possibly conflicting mesocyclone
    information
  • Early transition to MDA will decrease risk of
    legacy removal

6
Impacts to WSR-88D Architecture
  • Product Sizes
  • Unchanged
  • New API
  • None known
  • CPU
  • Unchanged
  • Memory
  • Unchanged

7
(No Transcript)
8
(No Transcript)
9
(No Transcript)
10
Design Approach
  • Add new Alert Code and Threshold in both the
    Volume and Forecast alert groups, retaining those
    for the legacy Meso alert until its removal in
    Build 10.
  • Increment version number for products containing
    Combined Attributes Table (CR/CZ (35-38) CRE/CZE
    (95-98)
  • Change the RCM product to report MDA features
    that meet the minimum display rank threshold
  • /NMES03 M05ABC M05DEF M06GHI
  • Change the Combined Attribute table in the CZ
    product
  • MDL requests version change

11
Design Approach (contd)
  • UAM Product

ALERT AREA 1
AZIMUTH
278.9 DEG
RANGE 22.1 NM
ALERT
CATEGORY MDA
THRESHOLD 5

EXCEEDING VALUE 6
STORM ID I0
STORM MOTION 216/ 55 DEG/KTS


12
Products MD PSB GAB(unchanged in Build 9)
  • Mesocyclone Detection
  • (MD, 141)

13
Products (contd)MD TAB (unchanged in Build 9)
14
Development Approach
  • ANSI C conforming to RPG Coding Guidelines.
  • Develop and test with Build 8v1 on dev3 Blade
    with connectivity to AWIPS lite.
  • Test on a Linux platform.
  • Coordinate product changes with FSL and MDL by
    providing samples for their testing.

15
Test Approach
  • cvt display of UAM and RCM as stand-alone
    alphanumeric products
  • AWIPS lite display of UAM and RCM using D2D text
    window.
  • cvg display of CR and CRE products.
  • AWIPS lite display of Combined Attributes Table
    in D2D window.
  • Test Cases
  • Full Load, 21 April 1996
  • No special test cases required.

16
Integration Challenges/Risks
  • RPG Risk Very Low
  • No change to CPU utilization, memory use or
    product sizes.
  • External User Risk Low
  • UAM Same format, new alert type
  • RCM Same format, new Part C content.
  • CR/CZ, CRE/CZE Same format, new GAB content.
  • Version number change has caused unexpected
    impact in the past.
  • How to treat low core and shallow features?
  • Linux platform testing challenge.

17
Proposed Schedule Summary(as of 10/02/05)
18
Action Items
  • _______________________________
  • _______________________________
  • _______________________________
  • _______________________________
  • _______________________________