Title: MR: Space charge and nonlinear field effects
1MRSpace charge and nonlinear field effects
01 Study of injection process
- Alexandre Molodojentsev
- KEK
- for MR-group
October 4, 2005
2MR initial beam
- Particle distribution
- Transverse particle distribution has been
created from the RCS_3GeVparticle distribution
(v. Noda_050906 95254mp) - MR_WP Qx 22.4281 / Qy 20.8195
- MR_SCR ?x 12.890 m, ?y 14.160 m
- ?x -1.456, ?y 1.456
- Distribution analysis
- ?x,RMS 7.1901 ? mm.mrad / ?y,RMS 8.3252
? mm.mrad - ?x,99 63.1456 ? mm.mrad / ?y,99
62.2008 ? mm.mrad - gt 54 ? mm.mrad H / V 2.025 / 2.198
- gt 81 ? mm.mrad H / V 0.23 / 0.15
3MR initial beam
- Particle distribution
- Longitudinal particle distribution UNIFORM
with the parameters - ?? ? 70 degree, ?p/p ? 0.3
Later replace it by a realistic longitudinal
distribution from RCS.
4Simulation approach
Main parameters 0.6 MW beam intensity RF ON
(h2) / two harmonics 280kV / 140kV Sextupole
magnets for Chrom.Correction ON NO any
ERRORS.
Tool ORBIT-MPI ( model) 95254 macro
particles Single processor machine (1.6GHz,
1MB???) CPU time 1 turn 75 sec
5MR initial beam
MR Scraper position particle distribution at
the transverse phase planes
Number of macroparticles 95254
6MR initial beam
Scraper Aperture 81 ? mm.mrad
MR Scraper position
gt 81 ? mm.mrad H / V 0.23 / 0.15
7RMS_emittance behavior
899_emittance behavior
Scraper Aperture 81 ? mm.mrad
particle losses at MR_SCR
9Particle losses at the beginning of injection
process
Scraper Aperture 81 ? mm.mrad
10RMS_emittance behavior
1199_emittance behavior
12(No Transcript)
13(No Transcript)
14Particle losses at MR_SCR
15Particle losses at MR_SCR(asymptotic estimation)
Asymptotic 1
Asymptotic 2
16- Possible sources for the emittance growth
17Foot_print after 4000 turns
NO sources for skew resonance Only
SpaceCharge and Sextupole resonances.
Qx2Qy64
2Qx 2Qy 3
2Qx-Qy 24
Qx Qy43
4Qy 83
3Qy 62
3Qx 67
18Normal Sextupole ResonanceQx2Qy64
OFF MOMENTUM (dp/p 0.007) / NO correction
/ VRF 280 kV, h9 Qx 22.34, Qy 20.80 LOST
at SCRAPER (81? mm?mrad) Beam ?x ?y 54
??mm?mrad
COSY symplectic tracking during 5000 turns ( OV
7 3 0 )
Presented on ATAC04
19Normal Sextupole ResonanceQx2Qy64
Correction of the 1,2 resonance has been
performed by two sextupole correctors CS21 CS31
for the working point close to the resonance Qx
22.40 , Qz 20.80
After correction dp/p0.007
Presented on ATAC04
20Potential limitation of the beam emittanceby
2Qx-Qy 24 (skew_sextupole)
21Beam survival scanning of QX 22.2022.50
ATAC2 meeting, March 7, 2003
81 ? mm.mrad
54 ? mm.mrad
COSY (9th order TM)
22 to do
- Particle distribution from RCS including a
realistic longitudinal distribution and
including effects of the beam collimator at the
RCS_MR beam line - Study of the single particle motion (edge
particles) for understanding main reasons of the
emittance dilution - a lot of things to do