Status of UCSB LT Testing
  • All 10 slots are equipped with UTRI, PAACB and
    adapter boards.
  • All 10 UTRI connected to multiplexer.
  • All 10 slots have HV connections with bias
    current monitored by electrometers.
  • 9 cold box plates available with adapter cards
    mounted on standoffs of correct height.
  • 4 PAACBs are connected for readout of module
    temperature sensors and low voltage currents.
  • Software reads out everything that is connected.
  • http//hep.ucsb.edu/people/gartung/ltdata

2
Module 1041
Module 1040
Module 1033
Module 1042
IV curves. Upper T23C, Lower T-15C,-18C,-20C
3
Leakage current versus time (temperature).
4
Module temperature sensor readings (blue,
magenta) Heat sink temp (red), carrier plate temp
(green)
5
Module 1037
6
Large amount of noise occasionally seen in
system. Might be faulty backplane connection.
7
Faulty backplane?
  • Connections through backplane made with stacked
    wire wrap connectors.
  • Pins are long and fragile and not rounded.
  • Pins have been bent while connecting adapter due
    to very slight misalignment (0.02 in) of
    standoffs.
  • Two HV connections through backplane are open.
    Made HV connection by using spare pin on PAACB
    and adapter board.
  • Large noise in the system that can go away when
    adapter board is reseated on backplane connector.
  • Rebuild backplane using PCB mounted connectors
    instead of stacked connectors.