1
CIRM ECDIS WG at IHO ECDIS Stakeholders Meeting
  • Nov 2007

2
Important Dates
  • MSC.191(79) Presentation of Nav Data, effective 1
    July 08.
  • 62288 CDV voting date 11Jan 2008
  • MSC.232(82) ECDIS, effective 1 Jan. 2009.
  • 61174 Ed3 CDV voting date 11Jan 2008
  • 62376 NP CDV, circ 26Oct07, voting date 1Feb
    2008
  • SN.1/Circ 266 ECDIS SW Maintenance, Oct 2007

3
IEC 62376 ECS
  • 62376 Committee draft ECS.
  • Three basic tasks left
  • alignment to 62288,
  • alignment/consistency with 61174,
  • completion of some test methods.

4
SN.1/Circ.266 ECDIS SW updating.
  • Means such as website to provide version and
    IHO compliance info to users. Manufacturers are
    inclinded to use their company websites (or other
    public access means) for this purpose.
  • Problem multiple IHO sub-documents versions.
    Difficult and confusing for the public to
    determine up-to-date compliance.

5
SN.1/Circ.266 ECDIS SW updating.
  • Suggested approach
  • IHO needs to show date of most recent change to
    the group of ECDIS and transfer standards,
    including revisions of any subdocuments or
    maintenance documents.
  • Public Info from Manuf (website) should state
    version of ECDIS SW and compliance with versions
    of IHO standards current as of date _____.
  • Approval test documentation must list the title
    and version of each IHO standard included in the
    compliance test.
  • SN Circ does not address a sunset period for
    compliance so national regulations could
    differ. Shipboard equipment should have a date of
    compliance not older than one year? from the
    most recent change in IHO ECDIS standard.

6
S63 Ed1.1 Questions
  • Re S63 Ed1.1
  • January 2008 submitted to IHO Member States for
    adoption.
  • Time period for voting?
  • Test data set status / scheduled completion?
  • Related Clauses in 61174 ed.3.
  • 6.4.3 Required test items S-57 ENC test data
    sets unencrypted and encrypted. (new)
  • 6.5.3 Encrypted ENC tests. Invokes S-63 data
    protection scheme.
  • 6.8.15.1(h). ENC delivery encrypted SENC. (new)

7
SENC Delivery type approval
  • Sec. 4.3 Appropriate checks/tests for the various
    types of recognized SENC formats will likely
    have to become part of the ENC Test Dataset that
    IHO needs to provide. This should involve
    cooperation between SENC providers, IHO and IEC
    TC80.
  • Will IHO please describe the process by which
    HOs (or member states) will approve SENC-version
    ENC test data sets? And SENC providers?
  • It seems incumbent on HOs (or Member States?) to
    approve these SENC-version ENC test data sets as
    an essential part of approval of each reseller or
    data-server.
  • 61174 6.8.15.1 (i thru k) states that for each
    SENC provider supported by the ECDIS-under-test,
    documentation of the approvals of the SENC
    provider, The SENC test data set from each
    provider shall be provided for inspection/test.