CALICE pixel Deep P-Well results - PowerPoint PPT Presentation

About This Presentation
Title:

CALICE pixel Deep P-Well results

Description:

Collection time still well below 200 ns in both cases, Next step: Complete layout simulation with and without 3 m PW guard ring ... – PowerPoint PPT presentation

Number of Views:12
Avg rating:3.0/5.0
Slides: 5
Provided by: EGV
Category:

less

Transcript and Presenter's Notes

Title: CALICE pixel Deep P-Well results


1
CALICE pixel Deep P-Well results
P-well contact ground
Nwells
P-well 3µm guard ring
Collecting diodes 3.6 x 3.6 µm2
Hit points
1
  • Bias
  • NWell 1.8/1V
  • Diodes 1.5V

6
50 µm x 50 µm pixel size
2
CALICE pixel Deep P-Well results
P-well contact ground
Nwell 3.6 x 3.6 µm2
P-well 3µm ring gap
Collecting diodes 3.6 x 3.6 µm2
  • Bias
  • NWell 1.8/1V
  • Diodes 1.5V

3
CALICE pixel Deep P-Well results
Guard ring
NO Guard ring
260 e-
Charge collected
Collection time
4
CALICE pixel Deep P-Well results
  • Conclusions
  • The final layout shows good performances in terms
    of charge collection, along the sampled line
    the worst case is again near the corner.
  • The 3µm guard ring version does not show
    remarkable differences ( a few e- ) compared to
    the no guard ring however, it might be
    beneficial for thinner epitaxial thickness
  • Collection time still well below 200 ns in both
    cases,
  • Next step
  • Complete layout simulation with and without 3 µm
    PW guard ring
  • Different size diodes simulations (7.6 / 1.8 µm)
Write a Comment
User Comments (0)