Description:

Store at 2 -30 C (36 -86 F). Pouch Front. Pouch Back. 8. Collection procedure. 9 ... a clean and dry collection container. Fill the cup to at least 1/3 full. ... – PowerPoint PPT presentation

Number of Views:103
Avg rating:3.0/5.0
Slides: 21
Provided by: rtl1
Category:

less

Transcript and Presenter's Notes

Title: Reditest Smoke Cassette cotinine screening device


1
Reditest Smoke Cassettecotinine screening device
Product Training Presentation
2
The information in this presentation is a general
overview on using the Reditest Smoke Cassette
cotinine screening device.
  • Product Training Contents
  • Reditest Smoke Cassette overview
  • Collection procedure
  • Testing procedure
  • Reading results
  • Sending presumptive positives for confirmation

Training Contents
3
Reditest Smoke Cassette technical information
  • It is important to read the package insert before
    using theReditest Smoke Cassette cotinine
    screening device.
  • Screening Results The Reditest Smoke Cassette
    is a rapid, one step test for the qualitative
    detection of Cotinine (nicotine metabolite) in
    human urine, and is used for determination of
    smoking status only. Positive results obtained
    with this device are presumptive.
  • Additional testing is necessary to confirm the
    presumptive positive results. Positive results
    should be confirmed by an alternate method such
    as GC/MS (Gas Chromatography/Mass Spectrometry).

Technical Info
4
Product overview
5
Reditest Smoke Cassette overview
  • Now you can easily and quickly find out if they
    use cigarettes and other tobacco products. The
    Reditest Smoke Cassette qualitatively detects
    Cotinine (nicotine metabolite) in a simple
    one-step urine test.
  • FEATURES BENEFITS
  • Detects Cotinine, a Nicotine metabolite, in
    urine at 200 ng/mL
  • Convenient to use and interpret
  • Fast on-site results in 5 minutes

Smoke Cassette Overview
6
Reditest Smoke Cassette components
Pipette
Smoke Cassette Device
Control Region (C)
Test Region (T)
Sample Well (S)
Smoke Cassette Overview
7
Reditest Smoke Cassette packaging
  • Part number, lot number and expiration date are
    located on the back of the foil pouch. Do not use
    after the expiration date. The test device should
    remain in the sealed pouch until use. Store at
    2º-30ºC (36º-86ºF).

Pouch Front
Pouch Back
Smoke Cassette Overview
8
Collection procedure
9
Collecting a urine specimen
Collect urine specimen in a clean and dry
collection container. Fill the cup to at least
1/3 full. This helps ensure proper specimen
volume for initial test and possible confirmation
tests.
Fill at least 1/3 full
Collection Procedure
10
Testing procedure
11
Testing procedure
Bring the pouch to room temperature before
opening it. Open the foil pouch and remove the
Smoke Cassette device. Place cassette on a
flat surface.Holding the pipette vertically,
transfer 3 drops of urine intothe sample well
(S).
3 drops in each sample well (S)
Testing Procedure
12
Reading results
13
Reading results
Wait for the colored line(s) to appear. Read test
results at 5 minutes. Do not interpret results
after 10 minutes as false results may occur.
Reading Results
14
Result interpretation
NEGATIVETwo lines appear. One colored line
should be inthe control line region (C) and
another apparentcolored line should be in the
test line region (T) PRESUMPTIVE POSITIVEOne
colored line appears in the control line region
(C). No line appears in the test line region (T).
Additional testing is necessary to confirm the
presumptive positive results. Positive results
should be confirmed by an alternate method such
as GC/MS (Gas Chromatography/Mass Spectrometry).
INVALIDWhen there is no line in the control
line area, the result is invalid. If an invalid
result is obtained repeat the test using a new
test device. If the problem persists, contact RTL
Client Services at (800) 255-2159, ext. 4399
NEGATIVE RESULT
C T
POSITIVE RESULT
C T
INVALID RESULT
C T
Reading Results
15
Reading resultsNegative Example
NEGATIVE line is present
Any visible line, evena faint line, indicatesa
negative result.
Reading Results
16
Reading resultsPresumptive Positive Example
POSITIVE line is not present
Presumptive positivefor cotinine (no line is
present).
Reading Results
17
Shipping specimens to the laboratory
18
Shipping specimens
For instruction on how to send presumptive
positive specimens to the lab, please view the
next document in the training series Specimen
Labeling Shipping. View online
herewww.redwoodtoxicology.com/resources/document
s/labeling_shipping.pdf
Shipping Specimens
19
If you have additional questions about your
device please contact a Sales or Client Services
representative Redwood Toxicology Laboratory,
Inc. Reditest Screening Devices3650 Westwind
Blvd. Santa Rosa, CA 95403www.redwoodtoxicology.
com
Sales Inquiries (800) 255-2159 or
877-444-0049 Client Services (800) 255-2159, ext.
4399 or 707-577-7959, ext. 4399
Contact Information
20
Thank you for your time.
99 000 0185 REV3
Write a Comment
User Comments (0)
About PowerShow.com