1
MIF II DIGITAL FEEDER PROTECTIONA
Comprehensive Protection solution for Feeders at
any voltage level
Functionality
F60
SR 750/760
F650
F35
MIFII
SR 735/737
Price
FMII
2
CONTENTS
INTRODUCTION What is MIF II?
APPLICATIONS
FEATURES BENEFITS
PROTECTION CONTROL Block Diagram
PRODUCT ARCHITECTURE Mechanical, Hardware,
Software
SOFTWARE enerVista MIF II Setup Software
COMMUNICATIONS
ORDER CODE
SUMMARY
3
INTRODUCTION
What is the MIF II?
Protection, control, metering, monitoring, and
analysis system
  • Supports ModBus communication protocol for
    integration with other IEDs
  • Applicable to Electrical Utilities and industrial
    systems
  • Best value for price
  • Building block for systems

Most Cost Effective Offering for Low and Medium
Voltage Feeders
4
APPLICATIONS
  • The MIF II can be used for
  • Comprehensive feeder protection for any voltage
    level
  • Backup protection for transformers, busbars,
    generators and large motors
  • Control functions breaker control (open/close)
    and recloser

Specify MIFII for Low End Feeder and Reclosure
Applications
5
FEATURES AND BENEFITS
The MIF II features advantage such as
  • Configurable logic
  • Configurable curve
  • Flash memory for field upgrades
  • Two setting tables
  • AC/DC power supply
  • HMI with 5 keys and a 2x16 character alphanumeric
    display
  • Isolated front RS232 serial port

State of the Art Features
6
BLOCK DIAGRAM
MIF II Protection and Control characteristics
Combine Overcurrent Protection and Multiple-shot
Reclosing in One Compact Relay
7
PROTECTION AND CONTROL
MIF II Protection functions include
  • Phase/Ground TOC
  • Phase/Ground IOC (two levels)
  • 4 preconfigured overcurrent curves (ANSI or IEEE)
  • Thermal image protection
  • 4-shot recloser
  • Cold load pickup function
  • Configurable breaker failure to open
  • Configurable I/O
  • 6 outputs trip, service required, auxiliary
  • Sensitive ground protection
  • Breaker opening/closing

Combine Overcurrent Protection and Multiple-shot
Reclosing in One Compact Relay
8
MONITORING AND METERING
  • The MIF II provides
  • 32 Event record
  • Analog/Digital oscillography
  • Breaker health monitoring through KI2 counter
  • Per phase current metering for primary or
    secondary values

Low Priced Scaleable Options Event Reports,
Waveform Capture, Breaker Monitoring
9
TYPICAL WIRING
10
HARDWARE
User Interface
DISPLAY LEDS
  • Text 2x16 display
  • Multicolor programmable LEDs with customizable
    label panel

KEYPAD
  • ESC/RESET key
  • UP/DOWN keys for easy navigation
  • ENTER function
  • Menu key

FRONT PORT
  • Electrically isolated front RS232 communication
    port

Easy to Use Man Machine Interface with
Communication Access
11
DIMENSIONS
Compact Design in a Modular Package for Easy
Maintenance
12
enerVista MIF II Setup Software
MIIPC Software provides the following functions
Logic
Settings
Oscillography
Metering
Powerful Configuration Tools That Get the MIF II
up and Running in Minutes
13
COMMUNICATIONS
  • A front mounted RS232 and a rear RS485 port allow
    easy user interface via a PC.
  • ModBus RTU protocol is used for all ports.
  • The relay supports baud rates from 300 to 19,200
    bps.
  • Up to 32 MIF II relays can be addressed on a
    single communications channel. A unique address
    must be assigned to each relay via a setting when
    multiple relays are connected.

Access to Information - Serial Communication and
ModBus RTU Protocol
14
MIF II ORDER CODE

15
Feeder Protection - MIFII
Functionality
F60
SR 750/760
F650
F35
MIFII
MIFII
M-Family Cost Effective Digital Protection
SR 735/737
Price
FMII
  • Target Applications/Industries
  • Low end three phase over current protection
  • Simple re-closure applications
  • Backup/auxiliary protection for transformers,
    generators and motors
  • Replacement/upgrade of E/M devices
  • Consultants, HQ engineering and end user
    utilities, OEM
  • Simple overcorrect protection applications
  • Key Values
  • Low priced scaleable options event reports,
    waveform capture, reclosure, breaker fail
  • Reduce troubleshooting and maintenance cost
    Event reports, waveform capture
  • Design flexibility Easy to use programming
    logic
  • Asset monitoring Breaker health, and breaker
    failure protection
  • Access to information Modbus RTU
    communications
  • Sales Strategy
  • Specify MIFII for low end feeder and reclosure
    applications
  • Specify 735 for customers that desire draw-out
    capability

Most Cost Effective Offering for Low and Medium
Voltage Feeders
16
MIF II SUMMARY
  • Reliable feeder protection and control for
    Electrical Utilities and Industrial applications.
  • User-friendly visual software for setting,
    monitoring, and metering. EnerVista compatible.
  • Password protected HMI for local operation.
  • Component based architecture for easy switching
    of internal boards.
  • Communications via front RS232, and rear RS485
    ports.

Web www.GEindustrial.com/multilin Tel 1
905-294-6222 Fax 1 905-201-2098 Email
gemultilin_at_indsys.ge.com
Most Cost Effective Offering for Low and Medium
Voltage Feeders