2PUMP LAYOUT
- THE PUMPS ARE LAID OUT WITH A COMMON MANIFOLD FOR
SUCTION DISCHARGE - ALL PUMPS ARE INDEPENDENTLY ISOLATED FOR
MAINTENANCE - SUCTION TAKEN
- OFF THE TOP
- OF THE MANIFOLD
3MATERIAL OPTIONS
OPTIONS
- MANIFOLDS
- 304 SS TUBE
- GAL MILD STEEL
- COPPER
- POLY
- SWITCHBOARD
- 304 POLISHED STAINLESS STEEL
- BRUSHED ALUMINUM
- VALVES
- SS BODY WITH SS DISCS
- SPEC VALVES AVAILABLE
4TYPICAL OPERATION
SET POINT
PUMP SPEED INDICATOR Hz
10
20
30
40
50
10
20
30
40
50
10
20
30
40
42
ON/OFF
SYSTEM PRESSURE GAUGE
- EACH PUMP IS STARTED
- ON THE VFD
5TYPICAL OPERATION
SET POINT
PUMP SPEED INDICATOR Hz
50
42
40
30
20
10
40
30
20
10
50
40
30
20
10
ON/OFF
SYSTEM PRESSURE GAUGE
PUMPS PICKED UP ON THE FLY ON THE WAY DOWN
6SYSTEM SELECTION
SELECT SMALLER PUMPS.
YES
INCREASE NUMBER OF PUMPS
IF NECESSARY
7DOLPHIN MODEL
- UP TO FIVE PUMPS PLUS JOCKEY PUMP
- AUTO ROTATE PUMP STARTS
- GRAPHICAL DISPLAY
- REMOTE CONTROL COMPATIBLE
- DATA LOGGING
- FULL PROTECTION FEATURES
- LIGHTNING PROTECTED
- SS PIPEWORK
- BUILDING MANAGEMENT OUTPUTS
- TOWN WATER SUPPLY
- IRRIGATION PROJECTS
- BUILDING SERVICES
- HOUSING SUBDIVISIONS
- HYDRAULIC SERVICES
- MINING
- SHIPBUILDING
8CONTROL PANEL
- THE CONTROL PANEL IS LOCATED AT EYE HEIGHT ON THE
FRONT OF THE SWITCHBOARD - MANUAL-OFF-AUTO SWITCHES OVERRIDE ALL AUTOMATIC
FUNCTIONS - ALL INTERFACE IS FROM THE EXTERIOR OF THE
SWITCHBOARD - ACTIVE GRAPHICS SHOW THE SYSTEM STATUS AT ALL
TIMES - CONTINUOUS FEEDBACK FROM THE SYSTEM
9SWITCHBOARD LAYOUT
MAIN SWITCH
FAN (NOT SHOWN)
VFD
PHASE FAILURE RELAY OVER/UNDER VOLTAGE
CONTROL CIRCUIT BREAKERS
MOTOR CIRCUIT BREAKERS
VARIABLE SPEED CONTACTOR
FIXED SPEED CONTACTOR
CONTROL TERMINALS INPUT / OUTPUT
MOTOR TERMINALS
ALL SIZED TO SUIT 5 PUMPS JOCKEY
10ELECTRONICS PCBs
11POWER SUPPLY
- FULLY REGULATED POWER SUPPLY
- OPERATE FROM 160 - 300 VAC
- DESIGNED FOR GENSET OPERATION
- TIMED STARTUP
- SURGE PROTECTED
- PRIMARY SURGE PROTECTION
- SWITCHING FOR SURGES 8 nano sec
- DIN RAIL MOUNTED
- MODEM POWER SUPPLY 9 V DC
- 24VAC NOMINAL INPUT
- 24VDC NOMINAL OUTPUT
12INTERFACE LAYOUT
Pump Status
screen
Key pad
13STATUS BAR
STATUS BAR
Time
Flowrate
Actual system pressure
Date
Compensated setpoint
Frequency of VFD Pump
COMMON AND REAL TIME ON EVERY SCREEN
14GRAPHIC SCREENS
15GETTING AROUND
16GETTING AROUND
17SMART KEY SECURITY
OPERATOR KEY OPENS TO SETPOINT SCREEN
COMMISSIONING KEY OPENS TO COMMISSIONING SCREEN
18SECURITY LEVELS
STATUS
OPERATOR
COMMISSIONING
19ERROR CALCULATION
SET POINT
SLOWER
ACCELERATION
FASTER
TIME
20PUMP SCREEN
- THE PUMP SCREEN SHOWS THE STATUS OF ALL THE
PUMPS - VFD SPEED
- DOL PUMPS
- MANUALLY SELECTED PUMPS
- DISABLED PUMPS
ICONS ROTATE WHEN OPERATING
21FLOWRATE SCREEN
- The flowrate screen shows the flowrate over the
past 96 hr period - This flow is calculated from the pump curves.
- Direct reading from a flowmeter is available as a
standard selection
22PRESSURE SCREEN
- The pressure screen shows the actual system
pressure over the past 3 hrs - The pressure is measured from a pressure
transducer
23ALARM SCREEN
- Each alarm occurrence is logged on the alarm
screen - The last alarm occurrence is held for viewing
- Reset by pressing the ENTER button
- Leave the alarm for future inspection by pressing
the right arrow key
24PUMP CURVE SCREEN
- This screen shows the pump curve for each pump in
the system - Any combination of pumps can be installed in one
pumpstation using this capacity
25SLIPPAGE
UNSTABLE
HEAD
CURVE BEFORE SLIPPAGE APPLIED
AFTER SLIPPAGE APPLIED-STABLE
EFFECTIVE CURVE ROTATION AFTER SLIPPAGE APPLIED
FLOW
26PRIME LOSS PROTECTION
ELECTRIC POWER IN HYDRAULIC POWER OUT
- THE DOLPHIN MEASURES THE CURRENT
- BEING DRAWN BY EACH PUMP
- AND COMPARES IT TO THE
- INPUT MINIMUM
- IF THE CURRENT IS LOWER THEN THE
- DOLPHIN WILL SHUT DOWN THE PUMP
- AND INDICATE AN ALARM
27OPERATOR SCREEN
28MULTIPLE SET POINTS
- UP TO 4 TIME OR EXTERNAL INPUT
- SET POINTS AVAILABLE
- VOLTAGE FREE ONLY
- EXTERNAL TIME CAN OPERATE TOGETHER
- WITH EXTERNAL OVERRIDING THE TIME
29PANIC ROUTINE
PANIC
- The ultimate 1 controller will always try to
maintain the set point pressure - Should the system pressure become higher than the
high pressure alarm a PANIC routine cuts in
and shuts down pumps until the set point is
reached and the system is stable
30COMMISSIONING SCREEN
- Commissioning screen is set on delivery at the
factory - All of the adjustment parameters can be modified
on site to suit varying requirements - Tuning of the system is easily done by the client
31SYSTEM COMMISSIONING SCREEN
- ALL PARAMETERS ARE SET PRIOR TO DISPATCH
- DETAILS OF ALL PARAMETERS ARE DETAILED IN
OPERATIONS MANUAL - DETAILED COMMISSIONING MANUAL AVAILABLE
32PUMP ENABLE SCREEN
- ALL PUMPS CAN BE DISABLED OR ENABLED FROM THIS
SCREEN - THE STATUS OF EACH PUMP IS SHOWN BY THE PUMP ICON
ON THE DISPLAY SCREENS - THIS SCREEN CONTROLS THE ALARM STATUS OF EACH PUMP
33VFD TEST SCREEN
- ANY PUMP CAN BE RUN AT ANY SELECTED SPEED
- THIS IS TYPICALLY USED FOR CHECKING PUMP ROTATION
34TRUE REMOTE CONTROL
- A Modem option allows connection of a Remote PC
to communicate with the pumpstation - Real time uploading
- allows ease of
- commissioning and troubleshooting
- All functions can be accessed and modified via
remote control
35SYSTEM SCREEN
36DATA LOG
37DATA LOGGING
- An easy to use Windows program allows total Data
Logging for all possible requirements - All data is available in Text file format for
direct spreadsheet insertion - Non pump items can be logged within the program
using auxiliary analogue inputs
- The RPM Software will log all relevant data
- Flowrate
- Totalized Flow
- Pressure
- Alarms
- Events
- Auxiliary 1
- Auxiliary 2
38EVENT LOG
39ALARM FAX
GOT A PROBLEM ?
SEND A FAX !
- The Ultimate 1 DOLPHIN RPM Program sends a fax
when the system detects a shutdown - Alarm messages are automatically sent to up to 4
Fax numbers with alarm system details