FS30 Ratio Adjustment
2
BRIXING AND RATIO
  • Set water flow rate first with ratio
  • cup at 15 ounces in 4 seconds.
  • Set syrup ratio with separator
  • (included with unit) and ratio cup
  • Set injected syrup with ratio cup

Separator
Ratio Cup
3
SETTING WATER FLOW RATE
closed
open
Valve Block
  • Shut off syrup (brand) supply to nozzle by
    closing
  • shut-off at back block, disconnecting coil
    wire at
  • plug connection or disconnecting BIB
    connector.
  • Dispense water into the brix cup for 4 seconds
  • Adjust to 15oz. of water in 4 seconds if needed

Flow Rate (3.75 oz./sec.) x 4 seconds
15.00 oz.
4
SETTING BRAND SYRUPS
  • Remove valve nozzle and install
  • syrup separator
  • Adjust syrup flow rate (at module)
  • so that water and syrup levels rise
  • together in ratio cup. Adjust syrup
  • module in (clockwise) to increase
  • the flow or out (counter-clockwise)
  • to decrease the flow.

Syrup
Water/Soda
5
SETTING INJECTED FLAVOR
  • Shut off water (soda) and brand syrup at valve
    block
  • Place ratio cup under nozzle
  • Activate bonus, then brand button at valve for 12
    seconds.
  • Adjust injected syrup flow to equal 2 oz. in 12
    seconds

closed
open
Valve Block