Series F4P 14 DIN Process and Temperature Controllers - PowerPoint PPT Presentation

1 / 57
About This Presentation
Title:

Series F4P 14 DIN Process and Temperature Controllers

Description:

F or C, degree, and decimal point indication. Operations display. 4 line X 20 characters per line ... are /- 1000 units/degrees. Offset values are linearly ... – PowerPoint PPT presentation

Number of Views:77
Avg rating:3.0/5.0
Slides: 58
Provided by: roger211
Category:

less

Transcript and Presenter's Notes

Title: Series F4P 14 DIN Process and Temperature Controllers


1
Series F4P 1/4 DIN Process and Temperature
Controllers
2
(No Transcript)
3
Watlows Next Generation Styling
Series V4T 1/4 DIN Temperature Controller
Series F4P Temperature and Process Controller
Series 97 Matching 1/16 DIN Limit Controller
4
F4P Focus Markets
5
Furnaceand Oven
  • Applications
  • Heat Treating
  • Kilns
  • Autoclaves
  • Foundry Metal Processing

6
Electronic Components and Assembly
  • Semiconductor processing equipment
  • Electronic assembly equipment
  • Test Equipment

7
Packaging and Sealing
  • Box Sealing
  • Shrink Wrapping
  • Blister Packing

8
Other FocusIndustries
  • Applications
  • Analytical Instruments
  • Pulp and paper processing
  • Petrochemical processing

9
Ease of Use
The most important selection factor following
quality and reliability when selecting a
temperature controller is ease of use.

Source1997 VDC Worldwide Market Report for
Industrial Electronic Temperature Controllers
10
Enhanced Display and Keypad
  • Control programming made easy through advanced
    technology
  • Icons for international applications
  • Read-at-a-glance process display
  • Full message prompting of operation and setup

11
F4 Operator Interface
  • Primary process display
  • Large 5-digit, 7-segment display
  • 0.562 (14.3mm) display digit height
  • F or C, degree, and decimal point indication
  • Operations display
  • 4 line X 20 characters per line
  • High definition back lit LCD
  • Wide viewing angle

12
F4 Operator Interface
  • 6 Operator interface keys
  • Rubber key switch with tactile feel
  • Four navigational keys
  • Parameter and value selection
  • i information key
  • Toggle for help
  • Dedicated Auto/Manual operation key

13
F4 Operator Interface
  • Discrete LED Indicators
  • Control output indication
  • Alarm active indication
  • Communications activity
  • Auto/Manual operation indication

14
Advanced Hardware Features
  • 20 MHz operation, 16-bit processor
  • NEMA 4X, IP 65 sealed front panel
  • Shallow 4 (101mm) overall case depth
  • FLASH memory for field software update

15
F4 Industrial Design Features
  • High strength injection molded case
  • 3.85 (97.8mm) behind panel depth
  • Ergonomic design styling
  • Compatible with Series 96 97 limit
  • NEMA 4X, IP 65 front panel seal
  • Convenient 4 screw installation brackets

16
F4 Industrial Design Features
  • Touch safe wiring termination
  • Removable for wiring convenience
  • Accepts 12 to 22 gauge wires
  • Positive latching feature
  • Connection integrity
  • Withstands equipment vibration

17
Loaded With Standard Hardware Features
  • 3 universal analog inputs (2 3 optional)
  • TC, RTD, process (no DIP switches)
  • 4 digital inputs (standard)
  • Control functions
  • Contact closure or DC voltage

18
Modular Hardware Inputs and Outputs
  • Field replaceable input and output modules
  • Dual control outputs
  • Reverse/Direct or Off
  • Linear or time proportioned
  • Switched dc/open collector, SSR, process
  • Alarms (2 standard)
  • Process, deviation, rate
  • 2 A mechanical relays

19
Leading the Way in Communications
  • Serial communications standard
  • EIA 232 EIA 485 hardware interfaces
  • MODBUS protocol
  • 9600 and 19,200 baud
  • Allows in field software updates

20
Hardware Features
  • Retransmit outputs
  • 2 optional
  • Current or voltage
  • Process, set points, power
  • Universal power supply
  • 85 to 265 vac/vdc, 50 to 60 hz
  • Optional 24 to 28 vac/vdc

21
Performance Specifications
  • Operating range
  • 0 to 65C
  • Calibration accuracy
  • 0.1 of span, /- LSD (whole digit)
  • Sensor update rate
  • 20 Hz, 50 ms, Input 1
  • 10 Hz, 100 ms, Input 2 and Input 3

22
F4 Hardware Architecture
Input to Output Isolation Minimum 500
Vac/Vdc between blocks
23
Agency Approvals
  • UL, c-UL 916 listed
  • User replaceable input and output modules
  • European CE conformity
  • EN 50082-2, immunity standard
  • EN 50081-2, emission standard
  • EN 61010-1 low-voltage directive, safety
  • NEMA 4X, IP 65 front panel seal

24
Software Architecture
Main Page
Operations Page
Setup Page
Factory Page
25
Software Architecture
  • Guided setup programming
  • Guided configuration
  • Presents a sequence of parameter choices needed
    to complete a functional configuration
  • Full unabbreviated text
  • Uses full text messages, not cryptic parameter
    and configuration names

26
Software Operation
  • Context sensitive help

Toggle the Information key
27
Process Value Bargraph Displays
  • View both
  • Output 1A and 1B in graphical format

28
Programming A User-Named Alarm
  • Select first line to change

29
Programming A User-Named Alarm
30
Programming A User-Named Alarm
31
Programming A User-Named Alarm
  • Select alarm on Output 1

32
Programming A User-Named Alarm
33
Programming A User-Named Alarm
34
Programming A User-Named Alarm
  • Enter VENT OPEN to name output

35
Programming A User-Named Alarm
  • Save change, output naming complete

36
Programming A User-Named Alarm
  • Return to normal operations display with Vent
    Open status displayed

37
F4 Software Architecture
  • Function naming
  • Optional, up to 10 characters
  • Better operator recognition

Enter Alarm Name Alarm 1 Adjusts
Character Selects Character
38
F4 Software Architecture
  • Pop up verification displays
  • Lets the user know when the F4 software is
    storing changes in Non Volatile Memory

Save Setup Changes or restore Values?
Restore Save
39
F4 Software Architecture
Main Page____ Go to Operations Go to Setup Go to
Factory
Main Page
  • Display key control parameters
  • Up to 16 customer programmable control parameters
  • Set points, alarms, errors, power
  • Inner loop set point (cascade control)
  • Bar graphs/set point and process
  • Gateway to controller configuration

40
F4 Software Architecture
Operations Page
Main Page____ gtGo to Operations Go to Setup Go to
Factory
  • Auto tune PID control parameter values
  • Edit PID crossover points
  • Digital set points
  • Alarm set points

41
F4 Software Architecture
Setup Page
Main Page____ Go to Operations gtGo to Setup Go to
Factory
  • Controller functional configuration
  • System settings
  • PID units, F or C, auto tune SP,
  • sensor failure, open loop, transfer power levels
  • Inputs analog and digital
  • Outputs control, alarm, communications,
    retransmit
  • Custom main page selections

42
F4 Software Architecture
Factory Page
Main Page____ Go to Operations Go to Setup gtGo to
Factory
  • Set lockout
  • Change password
  • Diagnostics
  • Date code, software revisions, etc.
  • Calibration data

43
F4 Temperature/Process Standard Operation
  • Open or closed loop operation
  • Automatic, closed loop control
  • Control action responds to differences in set
    point value
  • and process value
  • Manual, open loop operation
  • Control actions responds to manual changes to the
    controller output power levels.

44
F4 Temperature/Process Standard Operation
  • Five heat cool PID sets
  • Four crossover points programmable in the
    operations menu
  • Crossover based on set point or process value

45
F4 Temperature/Process Standard Operation
  • Auto/manual control operation
  • Manual to auto transition
  • Based on the last set point
  • Based on set point tracking (reverse bumpless)
  • Auto to manual operation
  • System menu choices for heat/cool transfer power
    levels

46
F4 Temperature/Process Standard Operation
  • Single or multi-point offset feature
  • Single-point
  • Linear across entire operating span
  • Multi-point (10 points and offset values)
  • Points can be positioned anywhere over the entire
    operating span -19999 to 30000
  • Offset values are /- 1000 units/degrees
  • Offset values are linearly interpolated between
    points

47
F4 Temperature/Process Standard Operation
  • Digital set point feature
  • Four namable set points
  • Activated via the four digital inputs
  • Set point values are entered in the operations
    menu
  • Set point name and value appear on the main page
  • Values can not be adjusted from the main page
  • Digital set points have priority over local set
    point

48
F4 Temperature/Process Standard Operation
  • Additional features
  • Process outputs
  • Duplex
  • 4 to 20 mA, 20 to 4 mA
  • Ramp to set point
  • Ramp on start up/ramp on set point
  • Square root input linearization

49
F4 Temperature/Process Standard Operation
  • Additional features
  • Custom messages
  • 4 user definable up to 50 characters
  • Activated by digital inputs
  • Displayed in main page
  • Tuning feature
  • Auto tune for heat only, cool only or heat and
    cool

50
F4 Temperature/Process Standard Operation
Main Page
  • Displayable options
  • Local or digital (namable) set point
  • Bar graphs
  • Set point, process value, output power value
  • Tune status, active PID set
  • Digital input status

51
Creating a Part Number
Temperature/Process Controller
F4P X - X X X A - X X X X
RG Displays Custom Options
Power Supply
Output 1A
Language Option
Output 1B
English, German Spanish, French
Control Operation (Standard or Enhanced)
Auxiliary Retransmit
52
F4P Feature Summary
  • F4P single channel
  • Single channel PID controller
  • 1 universal analog input
  • 4 digital event inputs
  • EIA232/485 comms
  • 2 alarm outputs

53
Reasons to Buy
  • Usability
  • High definition display
  • Information key
  • Guided set Up and programming

54
Reasons to Buy
  • Reliability
  • ISO 9001 manufacturing
  • Three year warranty

55
Reasons to Buy
  • Performance
  • Control accuracy
  • Extensive feature set
  • Exhaustive life qualification testing
  • Availability
  • 4 day lead-time

56
Reasons to Buy
  • Support
  • Local sales specialists
  • Applications engineering support
  • Rapid field returns department

57
Series F4P 1/4 DIN Process and Temperature
Controllers
Write a Comment
User Comments (0)
About PowerShow.com