Results from '04 in: - PowerPoint PPT Presentation

About This Presentation
Title:

Results from '04 in:

Description:

One run day with dedicated scans in beam power and plasma current. ... Beam voltage scans done at two fields. New diagnostic data from this campaign. ... – PowerPoint PPT presentation

Number of Views:17
Avg rating:3.0/5.0
Slides: 8
Provided by: ericfred
Learn more at: https://nstx.pppl.gov
Category:
Tags: results | run | up

less

Transcript and Presenter's Notes

Title: Results from '04 in:


1
Results from '04 in
  • 426 Collectively Driven fast ion losses
  • 427 NTM Threshold
  • 220 DIII-D CAE similarity experiment
  • New diagnostic results

2
Xp426 - Collectively driven fast ion losses
  • One run day with dedicated scans in beam power
    and plasma current.
  • Much more data collected throughout campaign.
  • No decrease of loss fraction yet seen at higher
    plasma current or beta (or "q(0)").
  • More subtle correlations are being investigated.

3
Experiments have found no empirical scaling of
fast ion loss with plasma current or b
  • Both TAE and chirping modes (fishbones, rTAE)
    seen to high b.
  • Thermal ion Landau damping expected to stabilize
    TAE at high b.
  • Precession drift reversal expected to stabilize
    chirping modes at high b bounce precession
    resonance is unaffected.
  • Reduced loss at high current expected (smaller
    rpol).
  • Both TAE and chirping modes contribute to fast
    ion losses in these events.

4
Xp427 - 1 day run of sawtoothing plasmas with
beta scans
  • Plan was to introduce repetitive "standard"
    trigger, look for NTM excitation, growth, decay.
  • Results not so clean, but very nice.
  • More data added from random sawtoothing shots.
  • Non-NTM n2 modes?

5
Soft x-ray data provides only internal
measurements
  • Island (tearing mode) suggested by phase
    inversion in soft x-ray data.
  • Mode amplitude drops substantially at sawtooth
    crashes not a feature of true NTMs.

6
Mp220 - CAE similarity study
  • CAE-like modes are also found in conventional
    aspect ratio tokamaks (DIII-D).
  • NSTX portion waiting for 6 kG capability.
  • Beam voltage scans done at two fields.

7
New diagnostic data from this campaign.
  • Poloidal array of fast Mirnov coils measurement
    of CAE poloidal structure.
  • Lost one coil to grounding problem.
  • Need work to understand phase shifts.
  • Multi-channel heterodyne reflectometer data on
    CAE in L-mode plasmas.
  • Should give internal measure of CAE (and TAE)
    mode amplitudes. Data available from at least on
    run-day.
Write a Comment
User Comments (0)
About PowerShow.com