First results of the SCECAL beam test - PowerPoint PPT Presentation

1 / 14
About This Presentation
Title:

First results of the SCECAL beam test

Description:

First results. of the SCECAL beam test. light yield problem. Jun-Suhk Suh ... Use fiber which is aluminized at the end. Use frame as reflector ... – PowerPoint PPT presentation

Number of Views:19
Avg rating:3.0/5.0
Slides: 15
Provided by: ilcph
Category:

less

Transcript and Presenter's Notes

Title: First results of the SCECAL beam test


1
First results of the SCECAL beam test light
yield problem
  • Jun-Suhk Suh
  • Kyungpook National University

2
Check linearity
Before Calibration
After Calibration
3
First results Linearity
very preliminary
Before Calibration
After Calibration
Total Energy (MIP)
Total Energy (MIP)
Incident beam energy (GeV)
Incident beam energy (GeV)
4
First results Energy resolution
very preliminary
Before Calibration
After Calibration
14
13
5
Shower profile at 1 6 GeV
6 GeV
1 GeV
Layer
Layer
Strip
Strip
Beam
Beam
6
Shower profile at strip 16,15,14
Strip 16
Strip 15
Strip 14
Layer
Strip
Beam
Beam
Beam
7
Shower profile at strip 1
6 GeV
Beam
8
Problem uniformity of a strip
48
75
66
KNU strip with fiber
Kuraray strip with fiber
Kuraray direct
9
Problem of reflector
10
Matching problem of MPPC fiber
11
Problem of hole size
Hole size
12
Solution
  • Reflector problem
  • Use fiber which is aluminized at the end
  • Use frame as reflector
  • matching problem of MPPC fiber
  • Use an adapter between fiber and MPPC
  • Production of new strip fiber embedded in the
    scintillator ? there will be no space between
    fiber and strip ? hole size will be exactly 1 mm

13
KNU
Shinshu Uni.
14
Check list
  • Fiber type KNU used Kuraray Y11
  • Comparison of light yield of Kuraray strip with
    hole groove
  • Shifted MPV position from maximum value
  • 2 Gaussian fit for the data before pedestal cut
  • Data before pedestal cut
Write a Comment