Title: MEG


1
MEG??????????????????? ??PMT???????????
???????60????? ????????????? 2005?3?24?
???? ???, ????, ????, ???, ?????, ????,
????, ???, ????, ???, ???,
???, ???? ?????? ???, ???, ????, ???? ???
????, ????, ???? ETH M.
Schneebeli INFN-Pisa A.Baldini, F.Cei,
S.Giurgola, M.Grassi, D.Nicolo, A.Papa,
G.Signorelli PSI P.-R. Kettle,
S.Ritt
2
Contents
p- beam test was performed to estimate resolution
in signal and higher energy region. (55 MeV and
83 MeV)
Updates and comparison of p- beam test in 2003
and 2004.
  • p- beam test
  • Updates from previous beam test
  • Analysis
  • Energy resolution
  • Time resolution
  • Summary

3
p beam test
LXe detector
NaI LYSO
LH2 target
??
83 MeV
p-p?p0n p0(28MeV/c) ? ? ? 54.9 MeV lt ?(?) lt
82.9 ?eV
170o
175o
Requiring ?gt170? FWHM 1.3 MeV Requiring ?
gt 175o FWHM 0.3 MeV
55 MeV
?
4
Result of Run-2003
Energy resolution
Time resolution
FWHM 4.5 0.3 s(right) 1.60 0.07
stXenon 102 psec
5
Updates from previous test
  • Result of beam test 2003
  • Energy 1.6 (right s)
  • Time 102 psec
  • Updates from previous beam test
  • Improvement of PMT
  • Newly installed calibration source
  • Filled space in beam window to reduce
    inefficiency.
  • High power refrigerator (189W_at_165K)
  • Waveform digitizer
  • New analysis softwares ( ROME )

6
Improvement of PMT
24pWJ H,Natoris talk
7
Newly installed a source
  • 4 tungsten wires plated with Au (50 micron f)
  • Po attached on the wires, 2 active points per
    wire
  • Active points are coated with Au (200-400Å)
  • Fixed on the wall with spring.

8
Analysis of alpha
Alpha source are used for Q.E. estimation
purity monitor optimization of MC
Q.E. of PMTs
Output of a PMT
1st generation
with ? selection
2nd generation
9
Energy Resolution
s 1.23
3cm
20cm
Energy ( of photons)
s 1.00
Depth ( arbitrary unit )

10
Energy resolution analysis
11
Intrinsic Time Resolution
L-R Analysis to ged rid of affection from
conversion depth reconstruction.
56 psec
Gain
43 psec
12
Absolute Time Resolution
st(Xe-LYSO) contains resolution of LYSO gt
61psec effect from beam spot and target size.
60psec
110 psec
103 psec
13
Absolute Time Resolution
st(Xe-LYSO) contains resolution of LYSO gt
61psec effect from beam spot and target size.
60psec
110 psec
103 psec
14
(No Transcript)
15
Practical Time Resolution
Practical timing resolution of Xe
LYSO
target
Intrinsic
depth
110 ? 64 ? 61 65 56 ? 33 psec
103 ? 64 ? 61 53 43 ? 31 psec
16
Comparison 20032004
17
Summary of p beam test
  • Many updates from previous test
  • PMT, calibration source, refrigerator, reduction
    of material, waveform, software ...
  • Energy resolution for 55 MeV gamma rays were
    improved from 1.6 to 1.2.
  • Time resolution for 55 MeV gamma rays were
    improved from 100 psec to 50 psec.

18
Summary of prototype tests
Prototype test is completed.
  • Energyposition resolution for 10,20,40 MeV
    gammas _at_ TERAS
  • Energytime resolution for 55,83 MeV gammas _at_ p-
    beam test
  • Liquefaction and keep LXe only with refrigerator
  • Attenuation length measurement and purification
    technique (pre-print physics/0407033)
  • PMT development and test
  • Calibration and reconstruction algorithms
  • High speed purification with liquid pump (lt100
    l/hrs).

MEG signal
Final detector is under construction.
19
Liquid phase purification
Liquid phase (high speed) purification was
successfully done.
Purifier
Teflon tube
Pump head