ILC Layout, 2-tunnel, Dogbone DR, conventional and undulator e source - PowerPoint PPT Presentation

1 / 11
About This Presentation
Title:

ILC Layout, 2-tunnel, Dogbone DR, conventional and undulator e source

Description:

Prepare both conventional and undulator based. Probably, start with conventional and ... Commissioning and Availability consideration (DR-ML sharing tunnel or not) ... – PowerPoint PPT presentation

Number of Views:23
Avg rating:3.0/5.0
Slides: 12
Provided by: kuboki3
Category:

less

Transcript and Presenter's Notes

Title: ILC Layout, 2-tunnel, Dogbone DR, conventional and undulator e source


1
For Overall Layout of ILC Beam Line Layout
Choices 200508xx K.Kubo
2
Possible Beam Line Layout of ILC-(A) Layout
based on following choices. Positron
source Prepare both conventional and undulator
based. Probably, start with conventional and
prepare space for undulator Place the undulator
at Ebeam 150 GeV (USTOS) Damping Ring Dogbone
DR, sharing tunnel with Main Linac. Avoid DR -
Main Linac interference in the first stage.
(Oide - scheme) Turn Around 180 degree turn
around after damping rings. This scheme allows
orbit feed-forward after DR.
3
(No Transcript)
4
Schematic Layout and length of each part
e- source e- 5GeV Linac (total 400 m)
Detector halls Dump halls
Turn around
e- DR (Straight section 7 km)
6.1 km
e- main linac (21.2 km)
e- BDS (1.9 km)
Spin rotator Bunch compressor
Undulator e source, 5 GeV Linac (total 1km)
e sourece, e 5 GeV Linac (total 1 km)
Turn around
Dump halls
e DR (Straight section 7 km)
e main linac (20.2 km)
e BDS (1.9 km)
Spin rotator Bunch compressor
Numbers should be reviewed by experts.
5
Energy upgrade scheme No DR-ML interference in
the first stage. (Oide - scheme)
turnaround
Electron
IP
e- DR
Undulator for e
Main Linac for upgrade to 1 TeV
Main Linac from the beginning
Positron
turnaround
e DR
Main Linac for upgrade to 1 TeV
Main Linac from the beginning
6
Possible Beam Line Layout of ILC-(B) Layout
without undulator based e source Positron
source Conventional. Damping Ring Dogbone DR,
sharing tunnel with Main Linac. Avoid DR - Main
Linac interference in the first stage. (Oide -
scheme) Turn Around 180 degree turn around
after damping rings. This scheme allows orbit
feed-forward after DR.
7
(No Transcript)
8
Possible Beam Line Layout of ILC-(C) Layout
without undulator based e source Without
O-de-scheme Positron source Conventional. Dampin
g Ring Dogbone DR, sharing tunnel with Main
Linac. Empty tunnel for 500 GeV ECM
operation. (It allows major preparations for
upgrade during operation.) Turn Around 180
degree turn around after damping rings. This
scheme allows orbit feed-forward after DR.
9
(No Transcript)
10
  • Of course, there are many other options
  • Independent DR tunnels
  • Undulator near IP
  • Decision will be mostly based on
  • Choice of e source technology
  • DR design, beam dynamics
  • Commissioning and Availability consideration
    (DR-ML sharing tunnel or not)
  • Overall cost

11
What should be considered from LET Beam Dynamics
(WG1) point of view
  • Low Emittance Preservation in
  • Low Emittance Turn Around after DR
  • This is essential for Feed Forward which allow
    reasonable stability tolerance of extraction
    kicker of DR. Need to design.
  • Long, Low Energy, Low Emittance Transport in
    Layout (A) (before turn around) and Layout
    (B)(after turn around)
  • DR-ML field interference (probably WG3b issue)
Write a Comment
User Comments (0)
About PowerShow.com