GLO-BRITE SITE SINGLE PIN BROKEN FIBER REPAIR
INSTRUCTIONS
PIN HOLDER ASSEMBLY
  • The pin holder assembly contains six wraps of
    fiber. If a fiber is broken at the pin, the
    repair will result in one less wrap of fiber.

WINDAGE PLUG
STEP 1
  • Remove the pin holder assembly from the sight.
    (Before removal, note the mounting location of
    the windage plug to make reassembly and
    re-sighting easier.)
  • Remove the screw in the bottom of the metal ring.
    The pin may now be removed from the sight by
    lifting it upward and out.
  • Remove the set screw on both sides of the metal
    ring and the flat head screw on the top of the
    metal ring.
  • Slide the clear aperture out of the metal ring.

REMOVE SCREWS
STEPS 2-4
CLEAR APERTURE
LIFT PIN UP
SLIDE APERTURE OUT OF THE RING
STEP 3
2
GLO-BRITE SITE SINGLE PIN BROKEN FIBER REPAIR
INSTRUCTIONS
  • CAREFULLY loosen the fiber from the clear
    aperture by gently pulling the fiber through the
    inner most hole and to the outside of the
    aperture.
  • Only pull enough fiber to be able to repair the
    pin. This is typically about 2-3 inches. Trim
    the broken end if necessary to make it straight.
    Trim the least amount possible.
  • Be sure not to sharply bend the fiber. If the
    fiber is cracked or bent too sharply, it will not
    function properly and should not be reused.

PULL FIBER DOWN AND OUT
INSIDE HOLE
OUTSIDE HOLE
STEP 5
3
GLO-BRITE SITE SINGLE PIN BROKEN FIBER REPAIR
INSTRUCTIONS
  • Rewrap the fiber around the aperture.
  • Push the fiber into the inner most hole from the
    outside of the aperture and back into the center
    of the sight.
  • Place the aperture back into the metal ring
    securing the fiber in the space allowed for it.
  • Replace the flathead screw at the top of the
    metal ring and the two set screws in the sides of
    the metal ring.
  • Do not over-tighten the two set screws. Stop
    tightening when you feel them make contact with
    the clear aperture.
  • Place the fiber through the hole in the fiber
    support on the back of the pin from the bottom
    end of the hole.
  • Place the pin in the square hole in the aperture
    and secure it with the 3/16 button head screw at
    the bottom of the sight.

FIBER SUPPORT
BOTTOM HOLE
STEPS 6-11
4
GLO-BRITE SITE SINGLE PIN BROKEN FIBER REPAIR
INSTRUCTIONS
  • Thread the loose end of the fiber through the
    hole in the pin from the back of the sight
    towards the front. Be sure the fiber seats in
    the fiber support slot. Trim the fiber to allow
    about 1/32 of fiber sticking out of the pin.
  • Flaring the fiber
  • Note Practice flaring the ends of the excess
    fiber before proceeding to flare the fiber in the
    pin.
  • Flare the end of the fiber by bringing a heat
    source such as a soldering iron close to the end
    of the fiber.
  • DO NOT TOUCH THE FIBER WITH THE HEAT SOURCE.
  • Remount the pin holder assembly into the sight.
    You can now re-sight your bow.