1ScanBay II Application Training
The Standard in Information and Diagnostic Systems
- By Arnold Vennink
- February 2005
Version 4.00 21-02-05
2ScanBay II
- ScanBay II hardware is the module that can
program the Scanner cartridges (EMB, PVCI and
TSI) and is connected to a PC via the USB
interface - The ScanBay II application software comes on a CD
for initial installation, all updates, ScanBay II
application and Software modules for VCS and TS
are automatically available via the internet. - Everything is installed on the hard drive
3USB ScanBay
- USB ScanBay
- EAK0253B31A SCANBAY USB KIT
- The installation CD has to be ordered separately
- 3-1332H10K1 V8.1
- Note USB ScanBay will be in the red color
4USB ScanBay Features
- Follows the new trend of connectivity
- No separate power supply needed
- Faster programming speed
- Better multi tasking capability
- Decrease in cost price
- These features are compared with the Parallel
ScanBay
5ScanBay II software
- Instantaneous updates via internet for
- ScanBay II Program
- VCS / TS modules
- Multiply users on one Kings Lynn account number
- Convenient billing
- Customer order number reference
- Price confirmation
- Email confirmation of order
- New Pricing structure
6ScanBay II Capabilities
- Programs VCS modules to PVCI and EMB cartridges
- Enable / disable VCS modules on preloaded PVCI
cartridges - Program TS modules on to a TSI and EMB Cartridge
- ScanBay II application software is available in
English, Spanish and German language - Not visible to the user
7Hardware Recognition
- ScanBay II will automatically recognize the new
hardware (PVCI/TSI) and the software modules that
are available for these cartridges. - EMB cartridge with EMB VCS and TS modules
- PVCI cartridge with PVCI VCS modules
- TSI cartridge with TSI TS modules
8PVCI ALL MAKES PRELOADED
- Empty PVCIs are delivered from the factory
preprogrammed with all modules,in a single
language - These modules are disabled. So they are not
visible in the Scanner. - This means for each language there is a Empty
PVCI. - When no module is
activated on the PVCI the scanner gives error
ini file missing or corrupt!
9PVCI ALL MAKES PRELOADED
- EESPGB905BC0 For English
- EESPDE905BC0 For German
- EESPES905BC0 For Spanish
- EESPFR905BC0 For French
- EESPNL905BC0 For Dutch
- EESPRU905BC0 For Russian
- EESPIT905BC0 For Italian
10PVCI ALL MAKES PRELOADED
- Advantage
- Enabling preprogrammed software is faster then
programming it. - ScanBay Application will call it always
programming.
11PVCI ALL MAKES PRELOADED
- Notes 1
- All requested modules need to be activated at
the same time, otherwise the multiple download
price discount will not take effect. - Off course you can activated the modules one by
one or other configurations
12PVCI ALL MAKES PRELOADED
- Notes 2
- On each Language PVCI you can add additional
language modules - When there is newer software available it will be
automatically updated/upgraded - This will not have the advantage of saving
programming time.
13PVCI / TSI Size
- The size of the
- PVCI is 512 Mb, 64 slots
- TSI is 384 Mb, 48 slots
- Mb is Mega bits
- MB is Mega Bytes
- There are no smaller sizes available as with the
EMB
The EMB was available in 32 Mb, 128 Mb and 256 Mb
4 MB 16 MB 32 MB
14ScanBay II system requirements
- Windows 1998, 2000 or XP
- CD-ROM and parallel port
- Internet explore 5 or higher
- Minimum 250 Mb hard drive space
- Internet connection from starting the program
until purchasing the software.
15USB ScanBay Installation
- First install the software.
- After the software installation is completed the
USB ScanBay can be connected to the PC.
16ScanBay II installation
- See also operators manual
- The CD is autorun
- If not start setup.exe on CD-ROM
- It will first install Microsoft.net.
- (This program runs in the background)
- ScanBay II software installation.
17ScanBay II installation
- Always log on as an administrator!
- Other ways it gives problems when logging on as
an other user.
18First start up 1
- Activation code is depending on
- Price file (ICTP, Italy, Spain, Distributor net
and Street)
19First start up 2
- User ID is locked to Kings Lynn account no.
- Each purchase is registered in ScanBay II
database with user ID - User ID is on invoice
- Email address will be used for order confirmation
E-mail.
20ScanBay II administrator
- For new accounts
- User IDs with password.
- Activation codes.
Use scanbay_at_sun-diagnostics.com
21First start up 3
- Leave proxy server always off, only in a very
view cases it is necessary. Can always be changed
later in the settings.
22ScanBay II software updates
- During each time running ScanBay II the program
looks for new ScanBay II application software on
the internet.
- An update could be mandatory.
23ScanBay II info update
- During the second stage of ScanBay II start up it
is downloading information from the internet
needed to run ScanBay II correctly.
24ScanBay II main screen
- Available modules
- Cartridge contents
- Web pages
- Four buttons to run the complete program.
- Make purchase
- Program Cartridge
- Home key for web pages
- Toolbox / options
25Toolbox / options
- When no cartridge in ScanBay II then some menu
points are not selectable. - User manual
- PDF file from the operators manual
- Cartridge details list.
26Toolbox / options
- Register new purchase is not used only when an
not known cartridge is added. (See next slight)
- Enter a new license key, in this a license key
can be entered that is given by the administrator
in case of no internet connection.
- About gives ScanBay II program version details.
27Unrecognized cartridge
- When inserting an Cartridge a pop up screen
Unrecognized Cartridge comes up then it is
never been registered ScanBay II. - Dont fill something in and press continue, the
cartridge will be added into the ScanBay II
database. - When there was software modules loaded on the EMB
they will not be known in the ScanBay II
database. - Send the cartridge contents screen to the ScanBay
II administrator to get them added to the
database.
28Options
- User details can be changed
- Network settings can be changed
- Application settings
- Pages to be skipped can be set
- Languages to show in module available window
29New Settings After Upgrade
Always Apply First And Then Ok.
30Available modules
- Modules available are shown
- All available
- Latest available
- This will also show previous bought modules
- VCS modules info
- Language flag
- Availability
- Hard drive
- Internet
- Licensed (yes / no)
- Slots required
31Available modules
- TS modules info
- Shopping trolley
- Ghosted if no modules are selected for purchasing
32TSI programming
- TSI programming
- When programming a TSI you have to read and
understand the following warning - In order for a TSI troubleshooter module to
operate correctly , a corresponding VCS(vehicle
communication software) module (of the same
language) is required.
33TSI programming
34TSI programming
- Corresponding means
- Same language
- Same brand
- And the VCS version must be equal or higher in
version as the TS version
35Cartridge contents window
- Memory slot status
- Shows direct if new modules are available
- Programming button
- Ghosted when there is nothing to program
- The displayed order doesnt reflect the order on
the cartridge, it is displayed in Alfa numeric
order. See cartridge details list in the tools
menu for more info.
36memory status bar
-
- It is always the same length, the light green bar
gives the percentage that is used
- When adding more modules than that can fit at the
end of the bar there will be a flashing white
spot.
37Web pages
- Business info page
- Administrator can give info and links to ScanBay
users
- Module info pages
- Links to (Future feature)
- Module info
- Application lists
- Adaptor lists
- Home Button
- To get back to Business info page.
38New / Upgrade / Update
- ScanBay II can recognize the difference
- New
- An new sales is when a module is never purchased
before for this EMB. New price will be charged - Upgrade
- An Upgrade is when we have added new models or
systems. The version numbers changes according to
the whole number before the decimal point. E.g.
5.2 to 6.1. Upgrade price will be charged.
39New / Upgrade / Update
- Update
- An Update is software in which we repaired bugs.
The version is recognizable by a change of
version number after the decimal point. E.g. 5.5
to 5.6. With this new SCANBAY II software this
is free of charge.
40New Pricing
- New pricing
- Competitive pricing for the more titles are
purchased in a single operation
41New Pricing
42Purchasing Wizard
- Continue shopping, Selected items are not
highlighted anymore but still in memory, even
when changing cartridge! - When this is not Ok then deselect that item
- Go to check out, guides you through the purchase
wizard
43Purchasing Wizard
Before confirming the purchase you can check the
invoice and add your order number / Customer
reference. only use ascii characters, others as
ß, ü, ä etc. will be replaced by under scores
"_"
44Confirmation Email
45Invoice
46Programming preparation
- Reselect the modules you want to program
- Move them to the cartridge by
- Selecting the arrow
- Drag and drop
47Programming wizard
48Second Upgrade 2004 VCS modules
- The following modules are upgraded.
- AFL V 3.1
- EOBD V 5.1 (German V 4.8)
- Ford V 7.1 (German V 7.2)
- Landrover V 7.1 (German V 7.2)
- Mercedes V 5.1 (German V 5.2)
- MG / Rover V 7.1 (German V 7.2)
- Opel V 7.1 (German V 7.2)
49Second Upgrade 2004 VCS modules
- Some of these brands are split in model year
coverage for example Mercedes - Version 4.5 covers 1990 - 2003
- Version 5.1 covers 2004 model years
- This is done because of different program
languages. The old model years are programmed in
the an old language and the new 2004 model years
are programmed in a new language which will be
used in the future. Old modules will be moved to
the new programming language so that they will be
one file for each brand in the future.
50Second Upgrade 2004 VCS modules
- Split brands are
- Ford V 6.3 and V 7.
- Landrover V 6.2 and V 7.
- Mercedes V 4.5 and V 5.
- MG / Rover V 6.2 and V 7.
- Opel V 6.7 and V 7.
51Second Upgrade 2004 VCS modules
- ScanBay II Application recognizes these brands
and handles them accordingly - Includes the lower version automatically by new
purchases - Updates the lower version by upgrading to the new
version if applicable - Programs both versions
- Purchases of upgrades and new split modules are
seen as one module.
52Second Upgrade 2004 VCS modules
- You can recognize these new split modules in the
ScanBay II application on the orange color of
these modules.
53Second Upgrade 2004 VCS modules
- In the confirmation Email the lower versions that
are included are mentioned as included.
ScanBay II Transaction Details Customer Order
Number 000000000002278 Account Number
777777 User ID arnold Comment Test12 Cartridge
ID 00000000ED160105183A1657190104ED Product
Description X2 VCS S/W LICENSE
Module Part Number 3-60527G10B0 Includes
Module Part Number 3-43527F20B0 Module Part
Number 3-58527E10B0 Includes Module Part
Number 3-41527D50B0 End of mail.
54User Notes 1
- Never remove the Cartridge when the LED on the
ScanBay is on. - This can hang-up the ScanBay application
- When inserting a cartridge it can take a few
seconds, depending on the internet connections
to the ScanBay server. - sometimes this can take longer then a view
seconds up to 2 minutes.
55User Notes 2
- When programming a PVCI it will always mention
slot 1.
56User Notes 3
- When purchasing new modules only select the
latest version of each brand / language. When
selecting two versions of the same brand /
language booth will be charged.
57Demo Cartridges
- With ScanBay II we can register Demo EMB, PVCI,
TSI Cartridges - Everything will be the same as normal in ScanBay
II but purchases will not be invoiced. (You will
not see this in the ScanBay II application, so a
Demo cartridge should be clearly market)
58Demo Cartridge rules
- Demo EMB, PVCI, TSI Cartridges must not be sold
- Demo Cartridges need to be set up in the database
by the ScanBay administrator. - The ScanBay administrator will evaluate the
request and inform you with the out come - Accepted
- Not accepted
59Demo Cartridge request
- When you request to setup a Demo EMB, PVCI or TSI
Cartridge you should give the following info by
Email scanbay_at_sun-diagnostics.com - Electronic ID of EMB, PVCI, TSI cartridge
- Hardware S/N of EMB, PVCI, TSI cartridge
- Distributor / Subsidiary name
- Salesman / demonstrator name that is using the
EMB, PVCI, TSI Cartridge - PVCI ID is 32 2 characters
60Tips for Mobile use
- Use GPRS / UMTS (G3) on data transport is charged
- Load at home the large files as
- ScanBay application program updates 1.8 Mb
- New software modules VCS 0,5 Mb TS max 3 Mb
- Each time starting up ScanBay II 310 Kb is
downloaded
61ScanTool Info Report
- The ScanTool info report is updated
- It has always to be send to
- scantool.info.report_at_snapon.com
- See for more info
- http//www.sun-diagnostics.com/ScanBay