Pressman's definition of"Software Quality"
  • Conformance to explicitly stated functional and
    performance requirements, explicitly documented
    development standards, and implicit
    characteristics that are expected of all
    professionally developed software.
  • text page 25

3
IEEE Definition of "Software Quality"
  • The degree to which a system, component, or
    process meets specified requirements.
  • The degree to which a system, component, or
    process meets customer or user needs or
    expectations.
  • text page 24

4
IEEE Definition of"Software Quality Assurance"
  1. A planned and systematic pattern of all actions
    necessary to provide adequate confidence that an
    item or product conforms to established technical
    requirements.
  2. A set of activities designed to evaluate the
    process by which the products are developed or
    manufactured. Contrast with quality control.

5
CMM
  • "The Capability Maturity Model for Software
    developed by the SEI is a framework that
    describes the key elements of an effective
    software process. The CMM describes an
    evolutionary improvement path for software
    organizations from an ad hoc, immature process to
    a mature, disciplined one."
  • "The CMM covers practices for planning,
    engineering, and managing software development
    and maintenance. When followed, these practices
    improve the ability of organizations to meet
    goals for cost, schedule, functionality, and
    product quality."

6
More Definitions
  • "software error" "software fault"
    "software failure"
  • types of errors
  • code error
  • procedure error
  • documentation error
  • software data error
  • text sections 2.1 and 2.2

7
Causes of software errors
  • faulty requirements definition
  • client-developer communication failures
  • deliberate deviations from software requirements
  • logical design errors
  • coding errors
  • non-compliance with documentation and coding
    instructions
  • shortcomings of the testing process
  • procedure errors
  • documentation errors
  • text section 2.3

8
Cost of Errors
  • "Software bugs, or errors, are so prevalent and
    so detrimental that they cost the U.S. economy an
    estimated 59.5 billion annually, or about 0.6
    percent of the gross domestic product.
  • Although all errors cannot be removed, more than
    a third of these costs, or an estimated 22.2
    billion, could be eliminated by an improved
    testing infrastructure that enables earlier and
    more effective identification and removal of
    software defects. These are the savings
    associated with finding an increased percentage
    (but not 100 percent) of errors closer to the
    development stages in which they are introduced.
    Currently, over half of all errors are not found
    until "downstream" in the development process or
    during post-sale software use."
  • US Dept of Commerce
  • June 2002

9
Some Famous Software Errors
  • Therac-25
  • Patriot Missile System
  • NASA's Mars Polar Lander
  • ESA's Ariane 5 Launch System
  • 2003 Blackout

many details stolen from www.wikipedia.org
10
Therac-25 - the problem
  • When operating in soft X-ray mode, the machine
    was designed to rotate three components into the
    path of the electron beam, in order to shape and
    moderate the power of the beam.
  • The accidents occurred when the high-energy
    electron-beam was activated without the target
    having been rotated into place the machine's
    software did not detect that this had occurred,
    and did not therefore determine that the patient
    was receiving a potentially lethal dose of
    radiation, or prevent this from occurring.

11
Therac-25 - the reasons
  • The design did not have any hardware interlocks
    to prevent the electron-beam from operating in
    its high-energy mode without the target in place.
  • The engineer had reused software from older
    models. These models had hardware interlocks and
    were therefore not as vulnerable to the software
    defects.
  • The hardware provided no way for the software to
    verify that sensors were working correctly.
  • The equipment control task did not properly
    synchronize with the operator interface task, so
    that race conditions occurred if the operator
    changed the setup too quickly. This was evidently
    missed during testing, since it took some
    practice before operators were able to work
    quickly enough for the problem to occur.
  • The software set a flag variable by incrementing
    it. Occasionally an arithmetic overflow occurred,
    causing the software to bypass safety checks.

12
Patriot Missile System
  • On February 25, 1991, the Patriot missile battery
    at Dharan, Saudi Arabia had been in operation for
    100 hours, by which time the system's internal
    clock had drifted by one third of a second. For a
    target moving as fast as an inbound TBM, this was
    equivalent to a position error of 600 meters.
  • The radar system had successfully detected the
    Scud and predicted where to look for it next, but
    because of the time error, looked in the wrong
    part of the sky and found no missile. With no
    missile, the initial detection was assumed to be
    a spurious track and the missile was removed from
    the system. No interception was attempted, and
    the missile impacted on a barracks killing 28
    soldiers.

13
Mars Polar Lander
  • The last telemetry from Mars Polar Lander was
    sent just prior to atmospheric entry on December
    3, 1999. No further signals have been received
    from the lander. The cause of this loss of
    communication is unknown.
  • According to the investigation that followed, the
    most likely cause of the failure of the mission
    was a software error that mistakenly identified
    the vibration caused by the deployment of the
    lander's legs as being caused by the vehicle
    touching down on the Martian surface, resulting
    in the vehicle's descent engines being cut off
    whilst it was still 40 meters above the surface,
    rather than on touchdown as planned.
  • Another possible reason for failure was
    inadequate preheating of catalysis beds for the
    pulsing rocket thrusters

14
Ariane 5 Rocket
  • June 4, 1996 was the first test flight of the
    Ariane 5 launch system. The rocket tore itself
    apart 37 seconds after launch, making the fault
    one of the most expensive computer bugs in
    history.
  • The Ariane 5 software reused the specifications
    from the Ariane 4, but the Ariane 5's flight path
    was considerably different and beyond the range
    for which the reused code had been designed.
    Specifically, the Ariane 5's greater acceleration
    caused the back-up and primary inertial guidance
    computers to crash, after which the launcher's
    nozzles were directed by spurious data.
    Pre-flight tests had never been performed on the
    re-alignment code under simulated Ariane 5 flight
    conditions, so the error was not discovered
    before launch.
  • Because of the different flight path, a data
    conversion from a 64-bit floating point to 16-bit
    signed integer caused a hardware exception (more
    specifically, an arithmetic overflow, as the
    floating point number had a value too large to be
    represented by a 16-bit signed integer).
    Efficiency considerations had led to the
    disabling of the exception handler for this
    error. This led to a cascade of problems,
    culminating in destruction of the entire flight.

15
2003 North America Blackout
  • August 14, 2003
  • 1215 p.m. Inaccurate data input renders a system
    monitoring tool in Ohio ineffective.
  • 131 p.m. The Eastlake, Ohio, generating plant
    shuts down.
  • 202 p.m. First 345-kV line in Ohio fails due to
    contact with a tree in Walton Hills, Ohio.
  • 214 p.m. An alarm system fails at FirstEnergy's
    control room and is not repaired.
  • 227 p.m. Second 345-kV line fails due to tree.
  • 305 p.m. A 345-kV transmission line fails in
    Parma, south of Cleveland due to a tree.
  • 317 p.m. Voltage dips temporarily on the Ohio
    portion of the grid. Controllers take no action,
    but power shifted by the first failure onto
    another 345-kV power line causes it to sag into a
    tree. While Mid West ISO and FirstEnergy
    controllers try to understand the failures, they
    fail to inform system controllers in nearby
    states.
  • 339 p.m. A First Energy 138-kV line fails.
  • 341 and 346 p.m. Two breakers connecting
    FirstEnergys grid with American Electric Power
    are tripped as a 345-kV power line and 15 138-kV
    lines fail in northern Ohio. Later analysis
    suggests that this could have been the last
    possible chance to save the grid if controllers
    had cut off power to Cleveland at this time.
  • 406 p.m. A sustained power surge on some Ohio
    lines begins uncontrollable cascade after another
    345-kV line fails.
  • 40902 p.m. Voltage sags deeply as Ohio draws 2
    GW of power from Michigan.
  • 41034 p.m. Many transmission lines trip out,
    first in Michigan and then in Ohio, blocking the
    eastward flow of power. Generators go down,
    creating a huge power deficit. In seconds, power
    surges out of the East, tripping East coast
    generators to protect them, and the blackout is
    on.
  • 41037 p.m. Eastern Michigan grid disconnects
    from western part of state.
  • 41038 p.m. Cleveland separates from
    Pennsylvania grid.
  • 41039 p.m. 3.7 GW power flow from East through
    Ontario to southern Michigan and northern Ohio,
    more than ten times larger than the condition 30
    seconds earlier, causing voltage drop across
    system.
  • 41040 p.m. Flow flips to 2 GW eastward from
    Michigan through Ontario, then flip westward
    again in a half second.
  • 41043 p.m. International connections begin
    failing.
  • 41045 p.m. Western Ontario separates from east
    when power line north of Lake Superior
    disconnects. First Ontario plants go offline in
    response to unstable system. Quebec is protected
    because its lines are DC, not AC.