The new standard in air filtration - PowerPoint PPT Presentation

1 / 29
About This Presentation
Title:

The new standard in air filtration

Description:

Developed by Lawrence Livermore Laboratories over 20 years ago ... Mite Allergens. 10-20. 5 minutes. Common Spores. 2-10. Bacteria. 1-5. Cat Dander. 1 0.5. 10 hours ... – PowerPoint PPT presentation

Number of Views:47
Avg rating:3.0/5.0
Slides: 30
Provided by: franksta
Category:
Tags: air | filtration | mite | new | standard

less

Transcript and Presenter's Notes

Title: The new standard in air filtration


1
Inactivating Airborne Pathogens through Air
Sanitization
April 28, 2009
Telephone 303.664.1140 Fax 303.664.1210 www.stri
onair.com
2
  • Agenda
  • Company Background
  • The Threat Nosocomial Infections
  • The Technology
  • The Product
  • Summary

3
StrionAir Founded To Improve Air Quality
  • Based on patented technology
  • Commissioned by the Department of Energy
  • Developed by Lawrence Livermore Laboratories over
    20 years ago
  • Financed by marquee private investors
  • Company formally launched in 2003
  • First product commercialized in 2005
  • Over 70,000 residential units shipped to date
  • Commercial markets growing rapidly
  • Healthcare, Commercial Office, Government
  • Over 170 facilities installed to-date

StrionAir leads in Low resistance/Germicidal
air purification
4
Well-Established As Leader in Safe, Healthy Air
Residential (OEM / Partnerships)
Commercial (StrionAir Brand)
Air Handler (whole facility)
Room / Unit (in condo/hotel room)
Whole-home
Portable
Healthy Homes
Germicidal Energy
5
  • Agenda
  • Company Background
  • The Threat Nosocomial Infections
  • The Technology
  • The Product
  • Summary

6
Demonstrated Need for Improved Air Quality in
Healthcare
  • 4 of top 10 Chronic Illnesses are Respiratory
  • Asthma, Bronchitis, Sinusitis, Allergies
  • CDC estimates 2 million nosocomial cases /yr
  • 2 for every hospital bed in the country
  • 10 chance of leaving a hospital with new
    infection
  • 5-10B in annual healthcare costs
  • Medicare no longer happy to pay
  • Present on admission reimbursement model
  • Airborne sources are a deadly participant
  • Estimated 10-20 of all HAIs from airborne
  • 120,000 annual cases are pneumonia
  • 39,000 of those afflicted DIED

SOURCE CDC, Eickoff, Durmaz, Kowalski
7
Small Particles Numerous and Harmful
  • A cubic foot of indoor air contains 1.5 million
    particles99 of these are smaller than one
    micron
  • Small particles, pathogenic or not, are the most
    damaging as they are carried deepest into the
    lungs

8
Small Particles Stay In The Air
9
Causes of Nosocomial Infections Are Widespread
Some Are Prevalently Airborne Virtually all
Can Be Airborne
SOURCE American Journal of Infection Control
10
And Infection Paths are Complex
Classifying Any Agent With Only One Infection
Route Is Risky
SOURCE Kowalski Air Treatment Systems for
Controlling Nosocomial
11
  • Agenda
  • Company Background
  • The Threat Nosocomial Infections
  • The Technology
  • The Product
  • Summary

12
A Quantum Leap in Air Purification
Electrically Enhanced Mechanical Filtration



Electrical Enhancement
High-efficiency filtration
With superior germicidal effect
Low resistance filter
This Is NOT An Ordinary Air Filtration Product
!!!!
13
Unique Electrical Approach, Plus Germicidal Effect
System Elements A Ionization Array B Field
Gen. Array C Media Filter
Air Flow
A
B
C
Slide 13
14
The Power Of Capture Kill on IAQ
Example Mold found growing on downstream side
of a HEPA filter
In Action StrionAir Systems Installed Impact on
Mold Measured by 3rd Party
15
With Power-On, A Powerful Technology
Becomes MERV 15
Electrically Enhanced
A MERV 9 Filter
Performance Rises Again Below 0.3 micron (meas.
by SMPS)
16
An Eye-Popping Low Pressure Drop 0.18 initial!
Filter Change
Filter Change
Filter Change
Pressure Drop Across Filter ( w.g.)
Typical Time to Filter Changeout (months)
Strion Change
17
Laboratory Tests Confirm Filter Kill Rates
Highly effective elimination of captured pathogens
CDC Laboratory Tests
Slide 17
18
Germicidal Test Results
19
All Performance Confirmed by 3rd Parties
StrionAir utilizes third-party testing to
objectively confirm efficiency and germicidal
effect
  • Performed ASHRAE 52.2 testing
  • Assigned MERV 15 rating at 500 FPM

LMS Technologies, Inc.
Centers for Disease Control and Prevention
University of Colorado at Boulder Civil,
Environmental Architectural Engineering
20
  • Agenda
  • Company Background
  • The Threat Nosocomial Infections
  • The Technology
  • The Product
  • Summary

21
Commercial System
Commercial System Details
Building Blocks!
Typical Installation
22
FEM Simple Elements, Elegant Design
Low resistance, disposable media filter
Ionization array
Field-generating array
Frame
Safety Screen / Upstream Ground
High-voltage Power Supply
23
FEMs Assemble Into Cut-To-Fit Racking
Spring Compression Sealing System
Pre-filter
FEM DFE
Extruded Aluminum Rack Members
24
New Construction Or Existing Buildings
Lower filter PD lower fan energy
Drop-in Replacement of Original Filtration
Upgrade filtration without energy penalties or
upgrade to other equipment
Reduce motor, blower, VFD size in a new AHU
Germicidal filter ? cleaner coils, further drop
in PD
25
  • Agenda
  • Company Background
  • The Threat Nosocomial Infections
  • The Technology
  • The Product
  • Summary

26
Product Summary Performance Efficiency
  • High Particle Removal
  • MERV 15 up to 95 of most-penetrating particles
  • Meaningful Energy Savings
  • Lowest pressure drop, by far, of any filter in
    the market
  • Ending pressure drop means reduced motor size,
    etc.
  • Germicidal
  • Broadly effective
  • Virtually 100 kill rate against airborne
    microbes and toxic mold
  • Cost-effective filtration
  • Filters last 2-3 times longer than traditional
    filters

27
US News World Report
  • Best Hospitals 2007 Respiratory Disorders
  • National Jewish Medical and Research Center,
    Denver, CO
  • Mayo Clinic, Rochester, MN
  • Johns Hopkins Hospital, Baltimore, MD
  • Massachusetts General Hospital, Boston, MA
  • Cleveland Clinic, Cleveland, OH
  • Barnes-Jewish Hospital, St. Louis, MO
  • University of Colorado, Denver CO
  • University of California, San Diego, CA
  • University of California, San Francisco, CA
  • Duke University Medical Center, Durham, NC

US News World Report, August 22, 2007
28
Marquee Commercial Installations
  • Healthcare
  • Cleveland Clinic
  • CDC
  • Commercial
  • National Geographic
  • Gaming industry
  • Government
  • World Bank
  • Federal Reserve
  • State Capital Buildings
  • Prominent Federal Agencies

And many other sites
29
Thank you for your time!