Title: Bullard PA30 Series PAPR


1
Bullard PA30 Series PAPR
  • Use and Care
  • Training Presentation

2
PA30 Training Presentation Disclaimer
  • This training presentation is intended as a
    supplement, NOT a replacement, to the information
    provided in the User Manual. Please read the
    entire User Manual prior to using the PA30 in any
    environment.

3
PA30 Principle of Operation
  • A PA30 Powered Air Purifying Respirator System
    consists of four components
  • Hood
  • Breathing Tube
  • Blower Assembly
  • Filters / Cartridges

CARTRIDGES
4
PA30 Principle of Operation
  • Battery Powered Belt Mounted Blower Unit draws
    air through three (3) cartridges connected to
    Blower Housing
  • Filtered Air is delivered through the breathing
    tube and into the workers hood
  • A design minimum of 7.5 cubic feet per minute
    (cfm) is delivered to the hood NIOSH requires
    only 6 cfm

5
Proper Use Warnings
  • Know the work environment and the potential
    hazards that could exist.
  • Do not use in atmospheres considered immediately
    dangerous to life or health (IDLH) as defined in
    29CFR 1910.134 (b).
  • Leave area immediately if
  • Breathing becomes difficult
  • Dizziness or other distress occur
  • You taste or smell the contaminant
  • Unit becomes damaged
  • Battery alarm sounds
  • This apparatus must not be used with the blower
    unit switched off. If the blower is switched off,
    a rapid build-up of carbon dioxide and depletion
    of oxygen may occur, which could result in death
    or serious injury.
  • Never alter or modify this respirator.
  • Use only NIOSH-approved Bullard components and
    replacement parts for this respirator.
  • Do not use in atmospheres containing less than
    19.5 oxygen.

6
Assembly
  • Secure suspension into hood by snapping into
    place
  • Attach Breathing Tube to Blower Unit, insuring
    gray seal is in place (below)
  • Make sure that cartridges and batteries are
    installed on blower unit
  • Attach the other end of the breathing tube to the
    hood by inserting the tube into the sleeve on the
    hood approximately 5 and securing with the
    anchor plate and clamp (right)

7
Pre-Operational Inspection
  • Ensure that the Blower Unit and Hood are clean
    and free from damage
  • Insure that all components are present for
    operation
  • Inspect for Deterioration, Physical Damage, and
    Improper Assembly
  • Check for proper airflow using the air flow
    indicator

8
Donning / Doffing
  • Follow proper assembly and pre-operational
    instructions
  • Donning / doffing should take place in a clean,
    hazard-free environment
  • Place the blower unit and belt around the users
    waist and adjust the belt for a proper fit
  • Turn on the blower unit
  • Place the hood on the head and adjust the
    suspension for a comfortable and secure fit

9
Low Voltage Audible Alarm
  • The alarm may indicate
  • Low Battery Voltage
  • Clogged or Damaged Canisters
  • Blower Malfunction
  • Breathing Tube or Hood Malfunction
  • If the alarm sounds, exit the work area
    immediately and review User Manual for
    Troubleshooting guidelines

10
Charging the Batteries
  • Place battery into charging port on the 2-port
    charger, or 5-port gang charger
  • The LED indicator will remain solid green while
    charging.
  • Allow the battery to fully charge the LED
    indicator will flash when the battery is fully
    charged
  • Observe additional battery charging and care
    precautions in the User Manual
  • After periods of extended storage or non-use,
    please refer to the User Manual for special
    charging procedure

11
Filters / Cartridges
  • Replace PA3HE Filters when Air Flow Indicator
    indicates insufficient airflow, or when
    administrative schedule dictates
  • Replace other Bullard cartridge types (PA3OVAGHE,
    PA3NBC) cartridges based on the required change
    out schedule which may be based on estimated
    service life, or administrative protocol

12