Title: Minstruments Workshop 13. March 08, Frankfurt
1Minstruments Workshop13. March 08, Frankfurt
- The New Generation Of
- Audio Signal Generators
2New Signal Generators
Available now!
Minirator MR-PRO
Minirator MR2
Digirator DR2
3Index
- 1st Part Analog Audio
- Minirator MR-PRO
- New Firmware and Accessories
- Distributed Speaker Systems, 100V
- Applications MR-PRO and AL1
- 2nd Part Digital Audio
- Introduction Digirator DR2
- Dolby Surround System Setup
4Analog Audio
5Introducing Minirator MR-PRO
- Generator Functions
- Sine, White / Pink Noise, Sweep, Chirp, Delay,
Polarity - WAVE File Playback- STI-PA, voice messages-
Sounds of music instruments - Additional new wave files- Band-limited 1/3
octave pink noise- Square waves
6New MR-PRO Firmware V2.01
- New Generator Features
- Fine Volt adjustments (e.g. "100 mV")
- Configuration files may be renamed when connected
as a mass storage device to a PC
7New Minirator Accessory
- Minirator -40dB AdapterAttenuator for high
quality microphone level signals (increases
signal-noise ratio) - Applicable for MR2 and MR-PRO.The MR-PRO
specifications are- Output level range -80 ..
18 dBu- Residual distortion (internal noise)
-96 dBu-gt minimum S/N ratio _at_ -80dBu 16dB
Minirator -40dB Adapter
8Application for -40dB Adapter
- Output level -60 dBu
- S/N ratio 26 dBu
- Adjusted level -20 dBu
- Actual output level after -40dB Adapter -60
dBu - S/N ratio 66 dBu
9MR-PRO Measurements
- Measurement Functions
- Phantom Power
- Balance Indication
- New Detailed XLR Cable Tester
- New Impedance Phase
- New Apparent Power Phase
10MR-PRO Measurements
- MR-PRO measures Phantom Power
- Phantom Power should be 48V /- 10.
- Application
- Checking inputs of mixing console.
Channel 1 Phantom Power is 42.6V instead of 48V
11MR-PRO Measurements
- Minirator MR-PRO measures
- Balance
- Impedance
- Application
- Checking inputs of mixing console.
Channel 1 ok
Channel 2 defective
Mixing console with defective channel 2
12New MR-PRO Firmware V2.01
- New Features
- Detailed cable test fault information
- Impedance measurement screen with - Impedance
Phase - Apparent Power Phase - Faster impedance measurement
13Detailed Cable Test
Cable
R2 1k
R3 2k
MR-PRO Remote Plug
XLR In
XLR Out
- Works perfectly on open ended cables
14Impedance Measurements
- Minirator MR-PRO V2.01 measures
- Impedance
- Phase
- Applications
- Frequency crossovers
- Electronic circuits
R 10 kohm
C 56 nF
XLR Out
15Impedance Measurements
- Tailored for testing 100V systems
- Measurement frequency selectable 30 Hz 10 kHz
- Replaces common impedance meters e.g. TOA ZM104
(320) or Goldline ZM01, RCS ZS-2, Sennheiser
16Distributed Systems, 100V
Distributed speaker system
2 W
2 W
2 W
17Distributed Systems, 100V
- Advantage 100V technology reduces line loses at
long distances from amplifier to speaker. The SPL
of each single speaker can be adjusted at the
speaker. The amplifier output level is 100V at
maximum load. - 70V systems- Power consumption of speaker is
only 50 compared to 100V- SPL reduced by 3dB - 50V systems- Power consumption of speaker is
only 25 of 100V- SPL reduced by 6dB
18Impedance Measurements
- MR-PRO Firmware V2.01 offers
- Impedance measurement with- Apparent Power
Phase - MR-PRO measurement unit VA
VoltAmpere VA
Watt W
19100V Loudspeaker Systems
Always disconnect the 100V amplifier for
impedance / power measurement with MR-PRO!
100 Volt Amplifier
20100V Loudspeaker Systems
- 100V Speaker System
- Power rating 2 W, typically _at_ 1kHz
- Transformer impedance 5 kohm
- MR-PRO measures
- Accurate Impedance 5.2 kohm
- Phase 13 inductive
- Power 2 VA(calculated by P U2/R
100V2/5200)
21100V Loudspeaker Systems
100V Speaker System Power rating 2
W Transformer impedance 5 kohm Power 6 VA
max. 100 Volt
2 W
2 W
2 W
22100V Loudspeaker Systems
- Sample problems onsite
- Speakers not connected
- Speakers wrongly connected or other electric
devices connected - Connection to wrong transformer taping, e.g. 1W
instead of 2W
only 2 of 3 speakers connected
one speaker wrongly terminated, 1W instead of 2W
23100V Loudspeaker Systems
- Sample problems onsite
- Short Circuits
- Mains Power Supply, use accessory MR-PRO
70/100V Protection - Other external voltages, such as fire alarm
devices connected - Bad connection cables
short circuit of speaker terminals
24100V Loudspeaker Systems
- Sample problems onsite
- Vibration and environment noise in the speaker
area effects speaker impedance. - Solution
- The MR-PRO impedance measurement includes
appropriate technology for stable readings in
noisy environments.
MR-PRO featuresstable impedance reading
25100V Loudspeaker Systems
max. 100 Volt
26New MR-PRO Accessory
- MR-PRO 70/100V ProtectionProtects Minirator
MR-PRO against accidentally applied voltages
during impedance or power testing at distributed
70V/100V speaker systems. -
27Application of 100V Protection
- MR-PRO is specified with max. input level
60 VDC. During operation of speaker system
the line level is up to 100V.
100 Volt Amplifier
100V Protection(adapter with fuses)
max. 100 Volt
28Application Minirator with AcoustilyzerHigh-res
olution Frequency Response
29High-res Frequency Response
- High-resolution frequency response up to 0.7Hz
steps
Acoustics measured by Acoustilyzer AL1 FFT mode -
LEQ
MR-PRO with Chirp Signal
Audio Amplifier
30High-res Frequency Response
- High-resolution frequency response up to 0.7Hz
steps - MR-PRO Chirp Signal Set start, - stop frequency
and time - Acoustilyzer AL1 FFT-Mode Set LEQ and Range and
resolution
MR-PROChirp Signal on
31Application Minirator with AcoustilyzerReverber
ation Time RT60 with 1/3rd octave resolution
32RT60 in 1/3 Octave Resolution
- The Acoustilyzer measures basically reverberation
time RT60 in 8 octave bands in the range from 63
Hz 8 kHz.
AL1 measures RT60 in octave resolution
Reverberation time RT60
33RT60 in 1/3 Octave Resolution
- New test signals extend the RT60 measurement to
1/3 octave resolution.
34RT60 in 1/3 Octave Resolution
- MR-PRO offers additional test signals for
extended 1/3 octave resolution. - How to do
- Load 1/3 octave pink noise test signals on MR-PRO
- Test1_1/3_low pink noise spectra of the 1/3
octave bands - 100Hz, 200Hz, 400Hz, 800Hz, 1.6kHz, 3.15kHz
- Test2_1/3_mid pink noise spectra of the 1/3
octave bands - 125Hz, 250Hz, 500Hz, 1.0kHz, 2.0kHz, 4.0kHz
- Test3_1/3_hi pink noise spectra of the 1/3
octave bands 160Hz, 315Hz, 630Hz, 1.25kHz,
2.5kHz, 5.0kHz
35RT60 in 1/3 Octave Resolution
- Reverberation Time RT60 with 1/3rd octave
resolution
Acoustilyzer AL1 measures RT60
MR-PRO with 1/3 octave Pink Noise Signal
Audio Amplifier
36RT60 in 1/3 Octave Resolution
Test 1
- Carry out individual RT60 measurements and load
test results into automated Excel-sheet.
Test 2
Test 3
37Summary
38Acoustic Set Pro
- Minirator MR-PRO
- Acoustilyzer AL1
- MiniSPL
- Cable Test Plug
- Mains Power Adapter MR-PRO
- Adapter -20dB
- Minstruments Case
39Thank you.