Title: DNP 3'0 solution for CitectSCADA


1
DNP 3.0 solution for CitectSCADA
Jens Nasholm Citect Pty Ltd
1
2
CitectSCADA and DNP
  • There is currently a new and an old version of
    the DNP driver supporting the DNP 3.0 standard
  • DNPr New driver with full support for
    redundancy
  • DNP Old
  • The DNPr driver is a native driver able to
    communicate with any device compliant with the
    DNP 3.0 standard
  • From January 1, 2006 a Specialty Driver support
    contract is required to log DNPr support calls

3
Old DNP Driver
  • Driver Name DNP (Latest version 1.04.09.001)
  • Overview
  • Used successfully by some customers
  • Quality and functionality ok for these customers
  • No redundancy
  • Solution
  • Upgrade existing systems to new version of the
    DNP driver
  • This driver should not be used in new CitectSCADA
    projects
  • Support
  • This driver is not supported and customers will
    be asked to upgrade to the new version of the DNP
    driver

4
New DNPr Driver
  • Driver Name DNPr (Latest version 3.01.07.000)
  • Overview
  • Used by majority of customers
  • Full support for PLC type redundancy
  • New features and number of defects resolved
  • Solution
  • Where possible, the DNPr driver should be used
  • Driver ships with CitectSCADA v6.1
  • Support
  • Supported by Citect Pty Ltd
  • From January 2006 a Support contract is required
  • DNP technical specialists available within Citect
    Pty Ltd
  • Defects will be prioritized and resolved based on
    severity

5
DNPr New features
  • Time stamped Trends
  • Trend events (Value Time) are pushed directly
    to the CitectSCADA trend system through API
  • No need for customer written Cicode all handled
    by the DNPr driver
  • Record with 1ms accuracy both analog and digital
    data for display in either the trending system or
    process analyst
  • Optimizes data storage by only saving values that
    are inserted (or changed)
  • Trend files automatically expand to fit data
  • No polling load on CitectSCADA

6
DNPr New features
  • Time stamped Alarms
  • Alarm events (State Time) pushed directly to
    the alarm system through API
  • No need for customer written Cicode all handled
    by the DNPr driver
  • Record with 1ms accuracy both analog and digital
    Alarms logged from RTU devices
  • No polling load on CitectSCADA

7
DNPr New features
  • Support of calculated variables
  • Calculations can be made within the cache before
    pushed into CitectSCADA
  • RealPower Voltage x Current x PowerFactor
    (where Power factor is 0.85)
  • Timestamp set to latest time from set of
    variables

8
DNPr New features
  • Redundancy
  • I/O Server level redundancy provides PLC type
    redundancy
  • No custom redundancy logics, such as dual-master
    logic, coding in the RTU required
  • The driver maintains a database of values
    received from devices known as the cache
  • The cache is updated by both event and static
    data
  • The cache is automatically updated between the
    I/O Servers upon change of data in the DNP devices

9
DNPr New features
  • Redundancy (contd)
  • Redundancy managed through Active State
    Detection of units and exclusive port access
    mode
  • A unit becomes active if either of the following
    occurs
  • Communication between the I/O Devices fails
  • The unit is forced into the active state by the
    user
  • If a unit on an I/O Device is not active
  • No communication with I/O devices.
  • It does not send any DNP3 frames to the device
    and does not process any frames received from the
    device
  • I/O Servers communicate with each other to ensure
    that a unit is active on only I/O Server at one
    time

10
DNPr statistics
  • Bluescope Steel Australia
  • 2 redundant I/O servers connected via TCP/IP to
    40 RTUs
  • 2 redundant Alarm/Report/Trend servers
  • 9000 DNP RTU tags
  • 5000 DNP RTU calculated variables
  • 7000 push-based digital alarms
  • 3000 poll-based digital alarms
  • 5000 event trends
  • 6000 periodic trends
  • 220_at_1s, 20_at_5s, 3500_at_60s, 2300_at_120s
  • RTU events are populated to the SCADA system at a
    rate of 220 events per second in peak load
    situations

11
Sample of CitectSCADA and DNPr users
  • Agility Gas Services
  • Barwon Region Water Authority
  • Booz Allen Hamilton
  • Cairns Water
  • City of Cape Town
  • Ergon Energy - Brisbane
  • Erie Boulevard Hydropower
  • French Broad EMC
  • GasNet Australia Limited
  • Goulburn Valley Water Authority
  • Origin Energy - Katnook Gas Plant
  • Origin Energy Spring Gully
  • Power Water - Sadadeen Valley
  • Queensland Railways
  • Shrewsbury Light and Cable
  • Texas Gas Transmission
  • Transend Power Stations
  • Transend Networks
  • TrustPower Generation
  • Western Power
  • Iran Khodro Substation Telemetry
  • Kangan Power Plant
  • Mashhad Powerplant Wells
  • Sistan Baloochestan Dispatching Centre