Title: Introducing


1
Introducing
  • The MPC-6000 and MPC-7000 Fire Alarm Panels from
    Faraday

2
MPC 6000 and MPC-7000 Features and Benefits
  • X1 Loop Technology
  • FireSmartTM Application Specific Fire Detection
  • Built in Sync Protocol
  • 2000 Event History Log
  • Built in Alm, Trb, Sup and Pwr Fail Relays
  • Programmable From Front Keypad or Windows Based
    Programming Software
  • Optional On-Board Digital Dialer
  • One Man Walk Test
  • Auto Program Feature

3
New X1 SLC Loop Protocol
  • Devices are polarity insensitive
  • 252 addresses on the loop
  • Devices operate on standard wire
  • No twist or shield required
  • Perfect for retrofits
  • Rapid response!

4
New X1 SLC Loop Protocol
  • MPC-6000 has a single X1 loop

MPC-6000
5
New X1 SLC Loop Protocol
  • MPC-7000 has two X1 loops expandable to 3, or 4

MPC-7000
6
Built-in Sync Protocol
  • Internal NACs are Syncd
  • No more wiring a separate sync module
  • Silence horns and keep strobes flashing using 2
    wires
  • NACs individually programmable

7
Increased NAC Power
  • Base 3A expandable to 6A on the MPC-6000
  • Base 5A expandable to 8A on the MPC-7000

8
More Signals, Less Expanders
9
Fully Networkable
  • MPC-6000 and 7000 will be MPC-Net compatible
  • MPC-6000 and MPC-7000 can network to existing
    MPC-1500s and MPC-1000s
  • Network cards mount in the enclosure
  • Fiber Optic interface!!!

10
Windows Based PC Programming Software
  • Laptop configuration is done with the CIS-4
    Programming software
  • All configuration options are at your fingertips,
    including
  • Custom messages
  • Detector addresses usages
  • Mapping inputs to outputs
  • Remote LCD annunciators
  • Programming relays LEDs
  • Dialer account phone number information

11
(No Transcript)
12
(No Transcript)
13
Option Modules
  • RDC-2 Remote Annunciator
  • Remote display with controls
  • Up to 16 on a system
  • MPC-DACT
  • Used on both the 6000 and 7000
  • Plugs on to main board
  • Transmits point or zone ID

14
Option Modules
  • NPE-1 Expansion Transformer
  • Boosts NAC power to 8A on the MPC-7000!
  • Boosts NAC power to 6A on the MPC-6000

15
Option Modules
  • SRU-2 RS-485 Relay Card
  • Drive up to 192 prgmbl. Relays on the 485 bus
  • SLU-2 LED/Lamp Driver Module
  • Drive up to 512 LEDs/lamps

16
Option Modules
  • 12603 Network Board
  • Network Interface Board(mounts in the enclosure)
  • 12536 Fiber Optic Interface
  • Single mode fiber converter
  • 12535 Fiber Optic interface
  • Multi mode fiber converter

17
Introducing
  • FireSmartTM Detection andInitiation Devices from
    Faraday

18
Our System Philosophy
  • Easy to Install
  • Easy to Program
  • Easy to Commission
  • Works Right When Needed

19
Siemens is the Detection Technology Leader
  • 1st Smoke Detector 1941
  • 1st Analog Addressable Detector 1982
  • 1st Application Specific Detector 1996
  • FireSmartTM Technology 1998
  • Worlds Most Sophisticated Fire Testing
    Facilities
  • Nobody Understands Fire Better

20
Our Detection Philosophy

21
Traditional Detection Concepts
22
Detector Response for Specific Applications

Alarm
Monitor
Receptive for typical fire phenomena
Immune to deceptive fire phenomena
Fire Tests
In- house
On- site
Standard Fire Tests
Experience and Decision Reference Values
23
FireSmartTM Application Specific Detection
  • A Revolutionary Fire Detection Method that
    Distinguishes Between a Fires Unique
    Fingerprint and Deceptive Phenomena and Only
    Reports Real Fires

24
FireSmartTM 11 Selectable Applications
  • Office(Retail) Reasonably clean, climate
    controlled

25
FireSmartTM 11 Selectable Applications
  • Office(Retail) Reasonably clean, climate
    controlled
  • Warehouse(Lt.Mfg) Airborne dust, equipment, fork
    truck, light to med. dock area exhaust fumes

26
FireSmartTM 11 Selectable Applications
  • Office(Retail) Reasonably clean, climate
    controlled
  • Warehouse(Lt.Mfg) Airborne dust, equipment, fork
    truck, light to med. dock area exhaust fumes
  • Lobby(Atrium) Relatively clean, temp
    changes, cell phone, smoking

27
FireSmartTM 11 Selectable Applications
  • Office(Retail) Reasonably clean, climate
    controlled
  • Warehouse(Lt.Mfg) Airborne dust, equipment, fork
    truck, light to med. dock area exhaust fumes
  • Lobby(Atrium) Relatively clean, temp changes,
    cell phone, smoking
  • Computer Room Very controlled, clean, closely reg
    temp, expensive machinery, no smoke, high air
    velocity

28
FireSmartTM 11 Selectable Applications
  • Office(Retail) Reasonably clean, climate
    controlled
  • Warehouse(Lt.Mfg) Airborne dust, equipment, fork
    truck, light to med. dock area exhaust fumes
  • Lobby(Atrium) Relatively clean, temp
    changes, cell phone, smoking
  • Computer Room Very controlled, clean, closely reg
    temp, expensive machinery, no smoke, high air
    velocity
  • Dormitory Living area, airborne dust, temp
    changes, cooking fumes, smoking

29
FireSmartTM 11 Selectable Applications
  • Office(Retail) Reasonably clean,
    climate controlled
  • Warehouse(Lt.Mfg) Airborne dust, equipment, fork
    truck, light to med. dock area
    exhaust fumes
  • Lobby(Atrium) Relatively clean, temp changes,
    cell phone, smoking
  • Computer Room Very controlled, clean, closely reg
    temp, expensive machinery, no smoke, high air
    velocity
  • Dormitory Living area, airborne dust, temp
    changes, cooking fumes, smoking
  • Healthcare Higher risk level, relatively clean,
    electronic equipment

30
FireSmartTM 11 Selectable Applications
  • Office(Retail) Reasonably clean, climate
    controlled
  • Warehouse(Lt.Mfg) Airborne dust, equipment, fork
    truck, light to med. dock area exhaust fumes
  • Lobby(Atrium) Relatively clean, temp changes,
    cell phone, smoking
  • Computer Room Very controlled, clean, closely reg
    temp, expensive machinery, no smoke, high air
    velocity
  • Dormitory Living area, airborne dust, temp
    changes, cooking fumes, smoking
  • Healthcare Higher risk level, relatively clean,
    electronic equipment
  • Parking Garage Airborne dust, car and diesel
    fumes, temp swings

31
FireSmartTM 11 Selectable Applications
  • Office(Retail) Reasonably clean, climate
    controlled
  • Warehouse(Lt.Mfg) Airborne dust, equipment, fork
    truck, light to med. dock area exhaust fumes
  • Lobby(Atrium) Relatively clean, temp
    changes, cell phone, smoking
  • Computer Room Very controlled, clean, closely reg
    temp, expensive machinery, no smoke, high air
    velocity
  • Dormitory Living area, airborne dust, temp
    changes, cooking fumes, smoking
  • Healthcare Higher risk level, relatively clean,
    electronic equipment
  • Parking Garage Airborne dust, car and diesel
    fumes, temp swings
  • Utility(Trans)Rm Normal to somewhat dirty, heat

32
FireSmartTM 11 Selectable Applications
  • Precious Storage Sensitive materials or eqpt
    storage, dust free environment, earliest
    warning desired

33
FireSmartTM 11 Selectable Applications
  • Precious Storage Sensitive materials or eqpt
    storage, dust free environment, earliest
    warning desired
  • Hostile Environment Dirty, dusty, humid,
    operating eqpt, RF, wide temp swings

34
FireSmartTM 11 Selectable Applications
  • Precious Storage Sensitive materials or eqpt
    storage, dust free environment, earliest
    warning desired
  • Hostile Environment Dirty, dusty, humid,
    operating eqpt, RF, wide temp swings
  • Duct(housing) Dirty, dusty, humid, wide temp
    swings, high air velocity

35
Signal Processing with FireSmartTM
Signal Processing with FireSmartTM Detectors
Detection
Interpretation
Continue to Monitor
Application Specific Algorithms
36
Inside the FireSmartTM Detector
Neural Network makes FireSmartTM the smartest
detector on the planet
Field cleanable chamber
Low Profile Design
Multi-color status L.E.D.
Responds to any or all three criteria (smoke,
heat, neural network)
Virtually instantaneous thermal response with
state-of-the-art thermistor
37

No False Alarm Guarantee Thank you for choosing
Faraday for absolute reliability in life safety
protection. FireSmart, the most sophisticated
fire detector available, is guaranteed against
false alarms. We are so certain of its
performance that we will pay any fines levied in
connection with false alarms caused by FireSmart
detectors. No Hassles, No Small Print, No Doubt
About It All we ask is that the detectors
operate with the proper application for the
environment in which the detector is installed
and programmed and that the system be properly
installed and maintained by a Faraday Brand sales
outlet. Its as simple as that. It works right
or we pay! FireSmart TM Anything else
just isnt smart ___________________
Philip C. Lake, President
38
8720 (Programmer/Tester)
  • Address and Test Devices
  • Loop Tester
  • Communication
  • Shorts
  • Ground Faults
  • Print Labels (Printer Optional)
  • Carrying Case (8721)
  • Printer Case (8722)

39
Competitive Comparison MPC-6000
40
Competitive Comparison MPC-6000
  • Feature Faraday MPC-6000 Notifier Onyx 640
  • Signaling Line Circuits (SLC's) 1 1 or 2
  • Maximum Addressable Devices 252 (504 pmgbl
    points) 318 Per loop
  • Built in Notification Circuits 4 Class B or 2
    Class A 4 Class A/B
  • Max NAC Power 6A 6A
  • Built-in Sync Protocol Yes Yes
  • SLC Loop Wire Requirements Standard Wire Twisted
    Data Grade
  • Polarity Insensitive Wiring Yes No
  • Manuf. Prov. a Means to Test Yes NoSLC Wiring
    for Shorts andGnds Prior to Inst. Of Fire Panel
  • Devices Can be Tested Yes NoPrior to Inst. Of
    Fire Panel
  • Auto Program Feature Yes Yes
  • No False Alarm Guarantee Yes No
  • Optional Point ID DACT Yes Yes
  • Peer-to-Peer Network Interface Yes Yes

41
Competitive Comparison MPC-6000
Feature Faraday MPC-6000 EST Quickstart Signaling
Line Circuits (SLC's) 1 1 Maximum Addressable
Devices 252 (504 pmgbl points) 250 Built in
Notification Circuits 4 Class B or 2 Class A 2
Class A/B Max NAC Power 6A 4.75 Built-in Sync
Protocol Yes No SLC Loop Wire Requirements Standar
d Wire Standard Wire Polarity Insensitive
Wiring Yes No Manuf. Prov. a Means to
Test Yes NoSLC Wiring for Shorts andGnds Prior
to Inst. Of Fire Panel Devices Can be
Tested Yes NoPrior to Inst. Of Fire Panel Auto
Program Feature Yes Yes No False Alarm
Guarantee Yes No Optional Point ID
DACT Yes Yes Peer-to-Peer Network
Interface Yes Yes
42
Competitive Comparison MPC-6000
Feature Faraday MPC-6000 FireLite
MS-9200 Signaling Line Circuits
(SLC's) 1 1 Maximum Addressable Devices 252
(504 pmgbl points) 198 Built in Notification
Circuits 4 Class B or 2 Class A 2 Class A/B Max
NAC Power 6A 6A Built-in Sync
Protocol Yes No SLC Loop Wire Requirements Standar
d Wire Twisted Data Grade Polarity Insensitive
Wiring Yes No Manuf. Prov. a Means to
Test Yes NoSLC Wiring for Shorts andGnds Prior
to Inst. Of Fire Panel Devices Can be
Tested Yes NoPrior to Inst. Of Fire Panel Auto
Program Feature Yes Yes No False Alarm
Guarantee Yes No Optional Point ID
DACT Yes Yes Peer-to-Peer Network Interface Yes No
43
Competitive Comparison MPC-7000
44
Competitive Comparison MPC-7000
Feature Faraday MPC-7000 FCI 7100 Signaling Line
Circuits (SLC's) 2 to 4 2 Maximum Addressable
Devices 1008 (2016pmgbl points) 394 Built in
Notification Circuits 4 Class B or 2 Class A 2
to 4 Class A/B Max NAC Power 8A 3A Built-in Sync
Protocol Yes No SLC Loop Wire Requirements Standar
d Wire Data Grade Cable Polarity Insensitive
Wiring Yes No Manuf. Prov. a Means to
Test Yes NoSLC Wiring for Shorts andGnds Prior
to Inst. Of Fire Panel Devices Can be
Tested Yes NoPrior to Inst. Of Fire Panel Auto
Program Feature Yes Yes No False Alarm
Guarantee Yes No Optional Point ID
DACT Yes Yes Peer-to-Peer Network
Interface Yes Yes
45
Competitive Comparison MPC-7000
Feature Faraday MPC-7000 Gamewell Identiflex
610 Signaling Line Circuits (SLC's) 2 to 4 1 to
4 Maximum Addressable Devices 1008 (2016pmgbl
points) 504 Built in Notification Circuits 4
Class B or 2 Class A 2 to 4 Class A/B Max NAC
Power 8A 4A Built-in Sync Protocol Yes No SLC
Loop Wire Requirements Standard Wire Data Grade
Cable Polarity Insensitive Wiring Yes Yes Manuf.
Prov. a Means to Test Yes NoSLC Wiring for
Shorts andGnds Prior to Inst. Of Fire
Panel Devices Can be Tested Yes NoPrior to Inst.
Of Fire Panel Auto Program Feature Yes Yes No
False Alarm Guarantee Yes No Optional Point ID
DACT Yes Yes Peer-to-Peer Network
Interface Yes Yes
46
Advantage
47
Why the MPC-6000 and MPC-7000?
48
Why The MPC-6000 and MPC-7000 Series?
  • The most advanced detection technology available
    today
  • Increased loop capacity means less wiring
  • Robust loop makes them perfect for retrofits
  • Increased NAC power means less boosters
  • Built in sync protocol
  • Windows based programming to make configuring
    the system fast and easy
  • Dialer that transmits accurate information