Stellaris - PowerPoint PPT Presentation

About This Presentation
Title:

Stellaris

Description:

B&L STELLARIS phacoemulsification system in biaxial and standard ... Eliminates external gas supply using all electric design. EQ VFM ... Control Pedal ... – PowerPoint PPT presentation

Number of Views:490
Avg rating:3.0/5.0
Slides: 12
Provided by: Robe333
Category:
Tags: stellaris

less

Transcript and Presenter's Notes

Title: Stellaris


1
Stellaris
  • Evaluation of the efficacy and of the safety of
    the new
  • BL STELLARIS phacoemulsification system in
    biaxial and standard phacoemulsification
  • Roberto Bellucci MD
  • Chief of the Hospital Ophthalmic Unit
  • Hospital and University of Verona, Italy
  • FINANCIAL INTEREST E

2
Stellaris EfficiencyUnique Handpiece
Stellaris handpiece and CustomControl
Software IIiled
  • New 6-crystal configuration for enhanced
    ergonomics and balance ideal for all hand sizes
  • 28.5 kHz for optimised cavitation, and rapid
    emulsification with minimal thermal loading
  • Precise control of power modulation for
    customised energy wave patterns and low overall
    phaco time
  • Locking irrigation connectors for added safety

3
The Vacuum Fluidics Module
  • Pioneering vacuum system for beyond Venturi
    responsiveness and aspiration efficiency
  • Vacuum limit increased from 550 mmHg to 600 mmHg
  • Advanced sensing technology accurately monitors
    and maintains targeted vacuum rise and
    intra-operative aspiration rate
  • Air and fluid venting system
  • Eliminates external gas supply using all
    electric design

EQ VFM
4
StableChamber Tubing
Safety
  • Small diameter tubing increases resistance for
    high vacuum and steady low flow
  • Internal mesh designed to capture material and
    prevent clogging
  • Minimises variability in steady-state

5
The Dual Linear Control Pedal
  • On demand independent linear control of
    aspiration and phaco power
  • Wireless connectivity for operating room
    convenience


6
Standard Phaco
1.1 mm phaco needles are available with
internal diameters 0.6-0.9 mm
7
My default settings
  • Phaco power
  • Micropulse 10 max power, 85 pps, 35 duty
    cicle
  • Vacuum
  • 0.8-0.9 mm lumen 400-450 mm Hg
  • Up to 0.7 mm 550-600 mm Hg
  • Slow rise 3-4
  • Bottle height 90 cm to 120 cm

8
Results
  • 100 consecutive surgeries
  • Vacuum module
  • Standard 1.1 mm needles with 0.6-0.9 mm internal
    lumen
  • Cataract hardness 2.21.3 (1-4)

9
Results
  • I case of chamber instability
  • No chamber collapse
  • Good holding and following ability
  • No case of tubing clogging (the filter stops lens
    fragments)

10
Conclusions
  • The new Stellaris phacoemulsification system is
    the ideal machine for both standard and 1.8 mm
    phacoemulsification
  • Better fluidics control with 1.1 mm needles
  • Better fluidics and phaco efficiency with 0.9 mm
    needles
  • Improved safety

11
Thank you for your attention
  • Roberto Bellucci MD
  • Verona, Italy