MuCool Test Facility Instrumentation Update - PowerPoint PPT Presentation

About This Presentation
Title:

MuCool Test Facility Instrumentation Update

Description:

Instrumentation Update. M. Haney, D. Errede, Z. Conway ... Instrumentation ... Instrumentation (2) FISO Fiber-optic strain and temperature ... – PowerPoint PPT presentation

Number of Views:36
Avg rating:3.0/5.0
Slides: 19
Provided by: MHA137
Learn more at: http://www.capp.iit.edu
Category:

less

Transcript and Presenter's Notes

Title: MuCool Test Facility Instrumentation Update


1
MuCool Test FacilityInstrumentation Update
  • M. Haney, D. Errede,Z. Conway
  • University of Illinois at Urbana-Champaign
  • 12/13 August 2002

2
Instrumentation
  • Seeking an intrinsically safe solution for
    instrumenting the LH2 absorber in the MTF
  • Prudent to accommodate MICEand European safety
    considerations
  • i.e. do it right the first time

3
Objective - Safety
  • Intrinsic safety, if possible
  • Limited power per channel
  • Good idea for Fermi required for Europe
  • Gas-purged enclosure, if necessary
  • 19 rack, 40U tall

4
Instrumentation (1)
  • Lakeshore 218S
  • 8 channel cryo temperature monitor
  • /- 21m K at 10 K
  • 16 readings/s
  • GPIB interface (to PC)
  • TG-120PL GaAlAs diodes (8)
  • -180mV/K at 4.2 K
  • B lt 5 T rad hard

5
Instrumentation (2)
  • FISO Fiber-optic strain and temperature
  • BUS chassis, with 4 (up to 8) modules
  • 1000 readings/s
  • RS-232 interface (to PC)
  • FOS-N strain sensors
  • /- 500 me 0.01 full scale 0.2mm O.D.
  • FOT-L temp sensors
  • 0.1 K resolution 1.5mm x 32mm (10mm active)
  • Slow 1.5 second response

6
Instrumentation (3)
  • Gateway E-4000 PC
  • 1.8 GHz, 1Gbyte RAM, 0.5Gbyte cache
  • 120Gbyte disk, Windows 2000
  • 15 LCD flat panel display
  • 640x480 CCD camera, microphone
  • PCI-MIO-16E-1
  • 16 channel ADC, 1.25 Msample/s, 12 bits, /-10 V
  • Tripplite Smart UPS
  • 3000 VA

7
Instrumentation (4)
  • IRM
  • 64 channel multiplexed ADC
  • 16 bit, 100 Ksamples/s
  • ACNET network connection
  • All PC data will be posted to IRM for ACNET access

8
Instrumentation (5)
  • MTL7055ac barriers
  • Low level AC
  • 24 W per line
  • 3 V max
  • MTL7060ac barriers
  • Star-connected AC
  • 101 W per line
  • 8.5 V max

9
(basic) Barrier
fuse
Power Signal
safe circuit
Return
Ground
10
Signals inside (the cryostat)
  • 8 (cryo) temperatures
  • readout via GPIB LabView (PC)
  • Multiple fibers
  • FISO strain, temperature (4)
  • Pressure, flow?
  • Laser occlusion (2)
  • Simple spark detectors (2)
  • (light pipe to photodiode)
  • 25(ish) 4-wire bolometry strips

11
(more) Signals inside
  • Piezo vibration sensor
  • via (16 chan/12 bit) ADC and LabView (PC)
  • Local (64 chan/16 bit) IRM channels
  • via LabView (see last slide)
  • MICE channels (?)
  • placeholder for the future

12
Signals outside
  • USB (4 wires, and shield) for CCD camera and
    microphone
  • via PC
  • Many voltages, currents, temperatures, pressures
  • magnets, beam position monitors, etc.
  • Most available from ACNET or local IRM
  • via LabView (see last slide)
  • or Cyro-PLC

13
Two Possibilities (1)
  • Intrinsically safe

Hazard Safe
Sealed Conduit(s)
Barrier(s)
ACNET
IRM
Cryo(temp)
FISO
PC w/16 chan ADC
network
power
Intrinsically safe signal conditioners and
transmitters
UPS
14
Two Possibilities (2)
  • Gas-purged box

Hazard Safe
Barrier(s)
Sealed Conduit(s)
ACNET
IRM
Cryo(temp)
FISO
PC w/16 chan ADC
network
power
UPS
15
This Summer Z. Conway
  • LabView interface
  • GPIB to cryo temp monitor - works
  • PC-internal ADC (e.g. for piezo) works
  • Simple ADC data read - works
  • High rate collection and compression not yet
  • IRM communications
  • IRM-ADC Read - works
  • Write any moment now
  • Integration remains!

16
Open Issues
  • WireShielding Concerns
  • Noise/sensitivity issues due to wirebarrier
    resistance?
  • Approx 12 W /ft for 36 AWG manganin wire
  • 48 W to 202 W added by barrier
  • And diode capacitance
  • Common mode (surges) due to magnets?
  • Need to protect electronics without burning
    barriers
  • Cable plant into solenoid

17
Open Issues (2)
  • Software Concerns
  • Posting data to the IRM
  • For ACNET access
  • Reading data from ACNET
  • For PC access
  • Remote control of PC
  • Citrix ICA, PCAnyWhere, etc.
  • LabView web-remote instrumentation
  • KVM?

18
Open Issues (3)
  • FISO strain and temp sensors
  • Not official rated below -40 C (!)
  • Temp has been used at 35 K (custom)
  • No experience with strain gages
  • Company very willing to work with us
  • To adjust signal conditioner, correction curves,
    etc.
  • Will require some form of agreement
  • Confidentiality, exclusivity for the instrument
  • Yet freedom to use and publish measurements
  • Also pressure, flow?
Write a Comment