Title: Michael Chrustowicz
1Power Management
Michael Chrustowicz APC Network Integration
Engineer
2(No Transcript)
3Built - in Serial UPS Support
Windows 2000, XP 2003 Developed by APC
APC worked with Microsoft to create an improved
built-in serial UPS capability to be included in
the Windows Operating System
- New serial UPS support is easier to use, more
reliable - Supports basic signaling for virtually all UPS
manufacturers - Microsoft has included enhanced support of APC
Smart and Simple-signaling UPSs in the operating
system
4(No Transcript)
5DEMO
6for Small, Medium, and Departmental Business
customers
PowerChute Business Edition
- Optimized for managing UPSs over a network
- Builds on Standard PowerChute plus features
- Many new features
- - Console with Centralized View
- - Mass Configuration
- UPS Status Report
- Security Username Password
- - Power Analysis
- - Recommended Actions
- - Wizard-based setup
- - Cross-segment discovery
7PowerChute Business Edition architecture
- Agents sit on each server and talk to UPSs
serially or via USB - Provides UPS status monitoring and, in the
event of an extended power outage, system
shutdown capabilities for your UPS-protected
computers. This software must be installed on
each of your computers that are directly attached
to one of the UPS systems.
- Server collects information from all Agents
- Used to configure and monitor the PowerChute
Business Edition Agents. The - PowerChute Business Edition Server gathers
information from the PowerChute - Business Edition Agents and provides
centralized event tracking, event notification - and a single point of contact for the
PowerChute Business Edition Console. - This software must be installed on one of
your networked computers.
- Management Console offers central view of all
the information. - Connects to the PowerChute Business Edition
Server to provide the user interface - for managing and configuring your
UPS-protected systems. Install the PowerChute - Business Edition Console on any workstation,
desktop or laptop - (running a supported operating system).
8PowerChute Business Edition architecture
PowerChute Business Edition Server
PowerChute Business Edition Console
9PowerChute Business EditionBuilds on standard
PowerChute plus features
- Full UPS Monitoring, Configuration, Control, and
Diagnostics - Graceful OS shutdown in the event of a extended
power outage - Graceful shutdown of popular server applications
- Lotus Notes
- SQL Server
- Microsoft Exchange
- Microsoft BackOffice
- Web servers (Apache, IIS, Netscape)
- Event Handling
- Broadcast notification
- Email and email/paging gateways
- Run command file
- Scheduled shutdown and reboot
- PowerNet SNMP Agent integration for NMS
- Support for Smart-UPS, Back-UPS, Back-UPS Pro and
Matrix-UPS - The PowerChute Business Edition Agent can
communicate with a supported UPS model that
connects through a Share-UPS or Interface
Expander.
10PowerChute Business Edition New Features
- Windows NT/2000-based Centralized Mgmt Console
- Mass Configuration - Wizard-based Setup
- Shutdown Schedule (version 6.1)
- Security User Password
- Power Analysis
- Recommended Actions
- UPS Discover
- Browser-Based Agent Interface
11Windows NT/2000-based Centralized Management
Console
12Mass Configuration - Wizard-based Setup
13Shutdown Schedule
14Security User Password
User Password security for PowerChute Business
Edition Agent Server
15Power Analysis
16Recommended Actions
- Displays probable cause of power event and
recommends a course of action to correct the
problem - Reduces need for training and speeds
troubleshooting
17UPS Discovery
- Reduces setup time by finding all UPS on the
network - 5-node - Local segment only - User can
enter individual IP addresses that are outside
the local segment - 25-node Includes Cross-Segment Discovery
18Optional Browser-Based Agent Interface
- Included with every agent
- Gives OS-independent client capabilities
- Almost identical to the Web/SNMP Management
Card interface - Included as an option we recommend the
Management Console instead.
192 Forms of Communication and what UPSs are
supported with PowerChute Business Edition
-
- Smart Signalling
- Back UPS Pro, Power Stack, Smart UPS, Matrix
- Full management, diagnostic, control
- and shutdown functions
- Simple Signalling
- Interface Expander, Share UPS, BK650MI,
- BK350CS, BK500CS, Silcon DP 300E, Symmetra
- UPS status information that we need for shutdown
- 1. Online
- 2. On Battery
- 3. Battery Charged
- 4. Battery Discharged
- 5. No communication
20Serial Cables
- Smart Signalling Cable AP940-0024C or AP940-
1524C (black) for all Operating Systems
Simple Signalling Cable AP940-0020B (grey)
for for all Operating Systems If you use
PowerChute Plus it will work only with Windows
2000, Windows NT, OS/2, Novell Netware, Windows
95/98 and ME
Simple Signalling Cable AP940-0023A (grey) only
for PowerChute Plus and Unix/Linux OS (except
Digital Unix, DEC OSF, SGI Irix, HP-UX on 800
Machines these operating systems work only in
Smart Signalling Mode).
21Isolated Extension Cable (AP9825i) AP9505i
The IEC allows for communication between servers
runningPowerChute Plus (Smart or Simple
Signalling) and APC UPS equipment to be extended
up to 100 meters.
Model AP9825i comes with a universal AC
Adapter (APC Part Number AP9505i) RJ45 Cable
(15 m) Extendable up to 100 meters
The box at the server end needs a universal 24 V
Power Supply (APC Part Number AP9505i) and Smart
or Simple Signalling cable. The box at the UPS
side will receive power from the serial port
22Two versions available Worldwide
- Free 5 Node Version
- Install wherever you want, as many times as you
want - (Agents, Server, Console) - Each Server can manage up to 5 agents
- Download from web and included with every
Smart-UPS soon, etc. - Purchase 25 Node version
- Convenience of managing up to 25 agents at once
(mass configuration, centralized event handling,
etc.) - Includes cross-segment discovery
- MANY additional features to follow
23PowerChute Business Edition Compatibility Chart
- Windows NT - PCBE Agent, Server, Console
- Windows 2000 - PCBE Agent, Server, Console
- Windows 2003 - PCBE Agent, Server, Console
- Novell Netware 5.1 6 - PCBE Agent only
- Solaris2.x (Sparc) - PCBE Agent only
- Red Hat Linux 7.x, 8.0 - PCBE Agent only
- Other platforms are supported with PowerChute
Plus
Free download from APC Web page!!!
24DEMO
25(No Transcript)
26Interface Expander ( 2-Ports ) and Share-UPS (
8-Ports)
- Share-UPS and Interface Expander allow the user
to connect multiple OS-independent servers to a
single UPS. - Both products work with PowerChute Plus (PC)
and PowerChute Business Edition (PCBE)
software. - Full UPS management, diagnostic, control and
shutdown functions are available in Smart
Signalling on the advanced port. Shutdown only is
available in Simple Signalling on the basic
ports. - Shutdown type
- - Low Battery Signal
- - Timer Mode
- - Confirm Mode
27Interface Expander
UPS Serial Port Advance port (Smart Simple
Signalling)
Mains Power
28Share UPS
29Smart Interface Expander
The Smart Signalling I/E is good for customers
who need to connect more than one server running
an OS which supports PowerChute Busienss Edition
or PowerChute Plus only with smart signalling.
- Operating Systems that are supported only with
Smart Signalling - Digital Unix (Compaq Tru64),
- SGI Irix
- HP-Ux on 300/800 Series servers
30Smart Interface Expander
Smart Signalling Cable
Smart Signalling Cable
31SmartSlot Relay Input/Output
APCs SmartSlot Relay I/O Module allows control
and monitoring of power through a simple dry
contact interface, a communication format favored
by manufacturers of PBXs, telecom management
devices, and alarm management systems.
- Input signals cause the UPS to do the following
actions - Turn the UPS on/off
- Initiate self-test
- Shutdown the UPS
- Output signals can be sent under 6 conditions
- UPS is on battery
- UPS has low battery
- UPS has lost communication with I/O Module
- Replace UPS battery
- UPS is overloaded
- Any UPS fault/self-test failure or overload
32 Out-of-Band Management Card
Out-of-Band Management Card allows user to
remotely manage a UPS. Provides complete UPS
information, paging on power problems and remote
safe reboot. Users can communicate with their
UPS during power outages or if the server is
down.
Modem
Phone network
Modem
Pager
33Out-of-Band Management Card Features
- Paging Capabilities
- - Out-of-band Management card can dial 2 pagers
to alert users about potential problems at
specific sites
- Security Features
- - User-selectable password protection
- - Dial back security (optional)
34Building Management Integration Card
A SmartSlot card allowing the customer to
integrate an APC Silcon UPS to their current
Building Management Solution. The card
communicates to the BMS via MODBUS/JBUS protocol.
In this way, UPS variables can be monitored
through various Building Management System
vendors software.
- The Building Management Integration Card requires
the - following
- An APC Silcon series (DP300E) UPS
- An APC Silcon Triple Chassis (AP9604Sincluded
with your Silcon series UPS)
35APCs Integrations
Example
Server
Gateway from BMS vendor
Translator from BMS vendor
UPS
Translator from BMS vendor
- Integrate with DataTraxs Foreseer II software
- Integrate with Automated Logic Corporation
software via Portal - Johnson Controls Metasys via MIG
36Automatic Transfer Switch
- 1400VA and 3000VA Automatic Transfer Switch
accessories offer network managers 7x24 AC power
and continuous availability of safe shutdown. - Automatic Transfer Switch has two input plugs.
It is designed to supply power to the load from a
primary AC line. If that AC power was not
available due to an overloaded circuit, failed
UPS, extreme weather, or even user error, the
Redundant Switch will automatically begin
sourcing power from the secondary AC line. The
transfer from on line to the other is seamless to
your server or networking device.
37Good In this application, the ATS is connected to
two separate AC sources. Loads with a single or
multiple power cords can now have N1 power paths
in case of a single AC source failure.
Better In this application, the ATS is connected
to two separate AC sources. A single Smart-UPS
is then connected to the ATS, thereby providing
the Smart-UPS with dual AC input feeds.
Best In this application, a ATS is used with two
identical Smart-UPS and PowerChute plus. Both
Smart-UPS will provide continuous EMI/RFI
filtering and surge suppression. Battery backup
is available in case of a primary or redundant AC
source failure. In case of a severe power event,
the redundant Smart-UPS will continue to support
the load and also provide graceful shutdown for
perating systems.
38MasterSwitch Standard Features
Network Power Distribution Unit for complete
manageability of your power.
- 8 individual outlet control attached devices
- Web/Telnet/ SNMP remote manageability
- Multiple-user definable accounts
- MD5- authentification
- 10A or 16A at 208V/230V
- Flash Upgradeable
- Universal power supply
- Horizontally mounted 1U space
39MasterSwitch Vertical Mount AP9222 (Controller
With SNMP Vertical strip) and AP9222EXPX166
(vertical expansion)
- 8 individually controlled outlets
- Web/Telnet/ SNMP remote manageability
- 16A/20A at 208V/230V
- Current sensing and set alarm thresholds
- Hardwire capable
- Power-up sequencing
- Flash Upgradeable
- Universal power supply
- Daisy chainable (only one controller is needed
for every 4 PDUs) - Vertically mounted "0 U" space
40(No Transcript)
41Environmental Monitoring Card
The Measure-UPS Card allows the customer to
monitor environmental aspects of designated
location.
- Sensors for temperature humidity continuously
monitor environment of your valuable equipment - 4 user-definable external inputs for use with
contacts, i.e. fire, water, smoke, unauthorized
entry, physical security or any external
condition that can be measured via contact
closure. - User-selectable thresholds allow you to decide
when you need to be notified of potential
environmental problems .
Lights
Air Conditioning
Intrusion
Smoke
42Environmental Monitoring Unit
- The Stand-Alone Environmental Monitoring Unit
(EMU) performs continuous temperature and
humidity sensing and contact monitoring without a
UPS connection.
- Product Features
- Temperature and Humidity Monitoring
- Contact Monitoring
- Notification via E-mail or SNMP
- Manageability via Web, Telnet, or SNMP
- Two user access levels administrative and device
management
43(No Transcript)
44Network Management Card
APC Network Management Cards provide full
management of UPS via multiple open standards
like Telnet, HTTP, FTP, and SNMP. Using the
10/100BaseT Network Management Cards, you can
monitor and configure your APC UPS to shut down
and reboot your computer systems, send Email
alerts and view the event log. The 10/100 Network
Management card adds scheduling and data-logging
along with a modular design for future features.
45Network Management Card
Network Management Card - AP9617
- Network Management Card - AP9619
- Relay I/O Module
- Environment Monitoring Probe
- Contact Monitoring
- Network Management Card - AP9618
- Relay I/O Module
- Environment Monitoring Probe
- Contact Monitoring
- - Modem out of band connection
46Network Management Card features
- UPS Management Status, Control, Configuration,
Diagnostic - In Band Management (10T 100T Based)
- HTTP, SSL, TSL access via WEB, secure
connection via SSL and TSL - Telnet, SSH access to text console, secure
connection via SSH - SNMP access via SNMP commands, integration into
Network Management Station - FTP, SCP firmware upgrade, download of the logs
files, secure connection via SCP - WAP read only access via mobile phone
- Logging
- Event Logging event log as a text file
download possible - Data Logging data log as a text file
download possible - Email Notification 4 different email recipients
- SYSLOG messaging for centralized logging
servers - Three User
- - Administrator access to all settings
- - Device Manager access to UPS settings only
- - Read only monitoring only
- Support Network Time Protocol automatic time
and date update
47(No Transcript)
48(No Transcript)
49Network Management Card Configuration
- APC Management Card Wizard
- Terminal Session (direct serial Connection)
- APC Security Wizard for
- - SSH finger print
- - SSL and TSL Certificates
50Firmware Upgrade
- Terminal Session direct
serial Connection - Xmodem
DO NOT USE APC WIZARD FOR FIRMWARE UPGRADE !
51DEMO
52Overview Features
PowerChute Network Shutdown
- Features
- Graceful System Shutdown
- Shutdown Confirmation
- Web Interface
- MD5 Authentication Security
- Run Command File
- Scalable Architecture
- UPS Status Checking
- Configurable Actions
- Configurable Conflict Detection
- Communication via Network
APC's PowerChute Network Shutdown software works
in conjunction withthe APC Web/SNMP Management
Card to provide graceful, unattended shutdown of
multiple computer systems over a network. Its
scalable architecture can support a virtually
unlimited number of client systems.
Administrators can quickly configure it via a
browser-based interface, and can customize
command files to run on each server in the event
of an unattended shutdown.
53(No Transcript)
54Installation of PowerChute Network Shutdown
PCNS asks forIP address, user name password of
the Web/SNMP Card !
During installation PCNS registers IP Address of
your machine into the Web/SNMP Card so that the
WEB/SNMP Card knows to which IP addresses it has
to send out the Alarms.
55How to access PowerChute Network Shutdown ?
- Open browser and use as address
- Access remotely - http// ltIP Address of remote
machinegt3052 - Access locally - http//127.0.0.13052
56(No Transcript)
57New PowerChute Network Shutdown version 220
supports more that one UPS !!!
Power Supply 1
Power Supply 2
NETWORK
58PowerChute Network Shutdown Compatibility Chart
Windows NT 4.0 PCNS version 220 Windows
2000/2003 5.0 PCNS version 220 Novell
Netware 5.x 6 PCNS version 201 HP-UX 10.2,
11.00 PCNS version 201 Solaris 2.x PCNS
version 220 AIX 4.3.x PCNS version 201 Red Hat
Linux 7.x, 8 PCNS version 220
Free download from APC Web pages!!!
59DEMO
60APC Enterprise Manager
- Real-time management and inventory reporting
application for APC power protection solutions. - Provides real-time status and recommended actions
for APC UPS systems and APC MasterSwitch
products. - Provides event notification via email based on
both user-defined thresholds and UPS alarms.
61APC Enterprise Manager
APC Enterprise Manager enables you to capture,
organize and assess, vital information concerning
your APC devices from a single console. APC
Enterprise Manager greatly simplifies management
of your power infrastructure by providing
centralized management for all your APC Equipment.
62Features/Benefits
- On demand battery status reports
- Detailed reports on battery age, load, health,
etc - Facilitates the timely replacement of UPS
batteries, reducing a major risk of downtime - Automatic email notification
- Emails administrators when UPS variables fall
outside user-defined thresholds - Eliminates need to proactively check on health of
APC power infrastructure - Downtime and On Battery Reports
- Unique reports help determine runtime necessary
throughout the network - Helps network administrators to increase
availability by pinpointing devices that require
additional runtime - Broad Support for APC Devices
- Including UPSs, MasterSwitch, APC Management
Cards, Environmental Monitoring Card and
PowerChute SNMP agents - Allows Network Managers to quickly access status
of their entire APC power infrastructure
63(No Transcript)
64APC Enterprise Manager Compatibility Chart
Windows NT - APC Enterprise Manager version
3.0 Windows 2000 - APC Enterprise Manager
version 3.0
Availability APC E-commerce website, or APC
Resellers
APC Enterprise Manager, up to 25 APC UPSs APC
Enterprise Manager, up to 100 APC UPSs APC
Enterprise Manager, up to 1,000 APC UPSs APC
Enterprise Manager, up to 10,000 APC UPSs
65Demo
66PowerNet Manager
- APC PowerNet Manager is a full featured robust
power management application that is tightly
integrated with Network Management Station. It
allows users to monitor and configure their APC
UPSs, as well as shutdown and reboot the UPS
67 Features Benefits
Administration
- UPS Operating Parameters
- UPS Identification Parameters
- SNMP Agent Parameters
- Put UPS to sleep
- UPS Self-test
- Test UPS Alarm
- SNMP trap based events logged in HP OpenView
- UPS Runtime Calibration
- Reboot Load
- Turn off UPS
- Safe System Shutdown
Diagnostics
Shutdown/Reboot
68(No Transcript)
69PowerNet Manager Compatibility Chart
- PowerNet Manager for CA Unicenter TNG
- PowerNet for Tivoli Enterprise
- PowerNet Manager for Novell ManageWise
- PowerNet Manager for Dell Network Node Manager
(NNM) SE - PowerNet Manager for HP OpenView Network Node
Manager (NNM) - PowerNet Manager for HP OpenView Workgroup Node
Manager (WNM) - PowerNet for CiscoWorks 2000
70Monitoring Software
71APC ISX Manager Location
72APC ISX Manager Hub
- Resides on top of PDU with the 32 port hub
- Gathers information from sub-systems
- 1 U thin Server
- 1 U thin Hub
- Does not affect availability of PSX
73APC ISX Manager General Overview
- Features
- Web-based GUI
- Auto-discovery of APC sub-system components
- Event Log
- User-configurable actions for event categories
- Notification via email to user(s)
- Time/date stamps alarms in event log
74Sub-systems in ISX Architecture
- APC Network Management Card Symmetra 3-Phase
UPS - Automatic Transfer Switch
- Environmental Monitoring Unit
- PDU and Outlet Strips
75APC Network Management Card Symmetra 3-Phase UPS
APC Network Management Cards provide full
management of UPS via multiple open standards
like Telnet, HTTP, FTP, and SNMP. Using the
10/100BaseT Network Management Cards, you can
monitor and configure your APC UPS to shut down
and reboot your computer systems, send Email
alerts and view the event log. The 10/100 Network
Management card adds scheduling and data-logging
along with a modular design for future features.
76Automatic Transfer Switch
U P S
U P S
ATS
APC's Automatic Transfer Switch (ATS), is a high
availability switch that has two input cords, one
for each AC line, which provide redundant power
to connected equipment. This product is designed
to supply power to the load from a primary AC
line. If that AC power becomes unavailable due to
any reason, the ATS will automatically begin
sourcing power from a secondary AC line. The
transfer time from one line to another is
seamless to the connected equipment.
77Environmental Monitoring Unit
- Stand-Alone Unit for network administrators to
monitor environmental conditions in a rack,
computer room and data center environments - General Features
- Temperature Humidity monitoring
- Web/SNMP Telnet management,
- Dry Contact inputs,
- E-mail notification,
- Event logging,
- MD5 Authentication,
- Rack Mount,
- Status Indicator LEDs
78Rack Mount PDU
- Single phase input capable
- 21 receptacles each per Base Building
Block - Universal twist lock connector
- Plug locking clips
- tool-less installation in Base Building Block
79ISX N1 Architecture
Information Controller PSX Hub
80ISX 2 N1 Architecture
Information Controller PSX Hub
81(No Transcript)
82APC ISX Manager Hub
83Remote Monitoring Network Integration Service
84Remote Monitoring Network Integration Service
85Questions ??
86Questions ??