Title: Fundamentals of Thermal Conductivity Measurement via ASTM 5470
1Fundamentals of Thermal Conductivity Measurement
via ASTM 5470
Analysis Tech Inc. 2007
2Trends in Electronic Cooling
- Increasing module and device heat fluxes
- Declining thermal design-margins
3Trends in System Costs
- Decreasing cost-performance ratio
- Increasing cost of system failure to end user
4Major Causes of Electronic Failures
Source U.S. Air Force Avionics Integrity Program
5Definition of Apparent Thermal Conductivity
ASTM 5470 is Ohms law applied to one-dimensional
heat flow.
Conductivity defined only for heat flow between
parallel, isothermal surfaces (ASTM 5470)
6Apparent versus Actual Thermal Conductivity
Hot Test Surface
Contact Resistance Rt
Q
Sample
L
Q
Contact Resistance Rb
Q
Cold Test Surface
kactual kapp If Rt Rb 0
Actual conductivity of sample equals apparent
conductivity only if contact resistances are zero
7Best Method for Conductivity Measurement
- best-fit data line -
RA
Intercept (Rt Rb)A
Sample Thickness
8Best Method for Conductivity MeasurementRequireme
nts
- Sum of Contact resistances must be the same for
all samples - (stacked samples have higher total
contact resistance) - Fractional composition must be the same all
samples - (supporting matrices or meshes cause problems
here) - Variable thicknesses must have uniform bulk
properties - (fabrication can yield thickness-dependent
properties) -
9Test Error Failure to Use Constant Pressure
(Type 2 Material)
10Contact Impedance Versus Pressure (Type 3
material, hard rubber, dry contact)
11Characteristics of Surface Contact Resistances
12Treating Surface Contact Resistances
13Type 1 Samples (ASTM 5470)
14Best Method for Conductivity Measurement(Type 1
Materials)
15Type 2 Samples (ASTM 5470)
16Best Method for Conductivity Measurement(Type 2
Materials)
17Type 3 Samples (ASTM 5470)
18Best Method for Conductivity Measurement(Type 3
Materials)
19Repeatability of TIM Measurements
20Accuracy of TIM Measurements
21TIM Tester 1300 Features
- Automatic operation under WinTIM Software
- Electronic sample thickness measurement -
"as-tested" - Sample-temperature control batch testing
- Automatic pressure control batch testing
- Controlled-thickness controlled-pressure test
modes - In-house calibration procedures
- English or metric unit selection
- Requires chiller, compressed air, PC computer
22TIM Tester 1300
23TIM Tester Pressure Range Options
- Kit 1 5 to 95 psi (60 to 650 kPa) /- 3
psi - Kit 2 10 to 170 psi (100-1100 kPa) /- 5 psi
- Kit 3 10 to 380 psi (100-2600 kPa) /- 10 psi
- Kit 3 recommended for mostly type 3 materials
- Kits 1 2 recommended for mostly type 1 2
materials - Pressure accuracy is /-2.7 of maximum pressure
- Kits can be changed by end-user and are available
in complete set of 3 kits.
24(No Transcript)