Title: USING DIFFUSIVE SAMPLERS FOR MONITORING FOR PPB LEVELS OF VOLATILE ORGANIC COMPOUNDS IN AIR
1USING DIFFUSIVE SAMPLERS FOR MONITORING FOR PPB
LEVELS OF VOLATILE ORGANIC COMPOUNDS IN AIR
- Linda S. Coyne
- Cindy A. Kuhlman
- Bruce J. Pacolay
2HISTORY OF DIFFUSIVE SAMPLERS
- Diffusive samplers were developed in the late
1970s - IH Professionals were skeptical about their
ability to accurately monitor concentrations in
the workplace - Face Velocity
- Reverse Diffusion
- Sampling Rate
3BADGE SUPPORTERS
- Testing continued on many compounds
- Recognition of their value and potential in the
workplace
- Advantages
- Required little training
- Small and quiet
- Unobtrusive to the worker
4MAJOR DEVELOPMENTS
- OSHA PUBLISHED FIRST VALIDATED METHOD IN 1998
- THEIR STUDIES INDICATED THAT DIFFUSIVE SAMPLERS
COULD ACCURATELY MONITOR VOCS IN THE WORKPLACE - PUBLISHED SEVERAL METHODS
- BENZENE
- MEK AND MIBK
- XYLENES
5CONTINUING DEVELOPMENTS
- AS BADGES WERE ACCEPTED, THEY WERE INVESTIGATED
FOR OTHER DISCIPLINES - Indoor Air Quality
- Ambient Air
- THESE DISCIPLINES WERE QUITE DIFFERENT FROM
INDUSTRIAL HYGIENE - Low face velocity
- High face velocity
- Extended sampling times
- Desorption efficiency at low microgram levels
6ENVIRONMENTAL PROTECTION AGENCY
- PUBLISHED AN ARTICLE IN DECEMBER 1999 ON INDOOR
AIR QUALITY - EPA LISTED THE 10 MOST FREQUENTLY MEASURED VOCs
IN OFFICE BUILDINGS - Dichlorodifluoromethane ? Trichloroethane
- Toluene ? Ethanol
- Acetone . ? 2-Propanol
- n-Hexane ? Xylenes
- Benzene ? Chloromethane
7TESTING PLAN
- Extend the original validation to include
parameters typical of indoor and ambient air - 24-hour sampling
- Lower concentration range 10-150 ppb
- Face velocity 10-20 cm/sec
- Desorption efficiency 0.2 to 10 micrograms
- Long-term reverse diffusion 1-5 days
8DIFFUSIVE SAMPLERS TESTED
- 575-001
- -350 mg of activated charcoal
- -In-situ desorption
- -Analysis by GC/FID
- -Detection limits in the 200-500 ng range,
depending on chemical
- 590-100(Ultra)
- -265 mg of Tenax TA
- -Thermal desorption with heated nitrogen
- -Analysis by GC/FID or GC/MS
- -Detection limits in the
- 1-2 ng range
9575-001 Sampler
10590-100 Sampler
11VAPOR GENERATION APPARATUS
Syringe Pump
Flow
Air Compressor
Drier
Charcoal Trap
Humidifier
Flow
Exposure Chamber
12DETECTION LIMIT IN PPB(BASED ON A 24-HOUR SAMPLE)
- 575-001 SAMPLER
- TOLUENE 3 PPB
- 590-100 SAMPLER
- TOLUENE 10 PPT
-
13DESORPTION EFFICIENCIES FOR THE 575-001 SAMPLER
14DESORPTION EFFICIENCIES FOR THE 575 SERIES BADGES
FOR ACETONE, HEXANE, AND p-XYLENE
15SAMPLING RATES(SR) FOR 24-HOUR SAMPLING
OFACETONE, HEXANE, AND p-XYLENEON THE 575
SERIES PASSIVE SAMPLERS10-100 ppb, 80 RH, 25 C
a) Validated by either SKC Inc. or OSHA Salt Lake
Technical Center for 8 hour sampling of compounds
in air.
16SAMPLING RATES(SR) FOR 24-HOUR SAMPLING OF
BENZENE, TOLUENE, AND o-XYLENEWITH THE 590-100
ULTRA SAMPLER10-100 ppb, 80 RH, 25 C
175-DAY REVERSE DIFFUSION DATA WITH THE 575 SERIES
PASSIVE SAMPLER RECOVERY
18REVERSE DIFFUSION EXPERIMENT FOR BENZENE AND
XYLENE WITH THE 575-001 SAMPLERMicrograms