Muon Reco Immediate Software Tasks D' Hedin NIU 21202 - PowerPoint PPT Presentation

1 / 4
About This Presentation
Title:

Muon Reco Immediate Software Tasks D' Hedin NIU 21202

Description:

Tune rcp RS/DH. III. Tracks, etc. A. Scint only in muo_segmentreco. In cvs PdJ ... tune DT to position function by comparing to location of a-phi counter. Plot ... – PowerPoint PPT presentation

Number of Views:19
Avg rating:3.0/5.0
Slides: 5
Provided by: David60
Category:
Tags: niu | hedin | immediate | muon | reco | software | tasks | tune

less

Transcript and Presenter's Notes

Title: Muon Reco Immediate Software Tasks D' Hedin NIU 21202


1
Muon Reco Immediate Software Tasks D. Hedin NIU
2/12/02
  • Have informal meeting on Tuesday off weeks
    230-400 in the Doghouse(?)
  • I. Hits
  • A. multiPDT hits from same cell DH/MF
  • muon_raw,muo_hit. In t02.04 not p?
  • B. PDT t-gtd for MC in p02.04 not p? DH
  • C. unpack PDT pads correctly status? MF
  • D. use calibration database
  • muo_hitreco,muon_raw status? AK
  • muon_index ADB needs table MF/AK/DW
  • DH questionwhat if databasetrue for MC?
  • E. second pass PDT deltaT muo_util
    DH
  • F. use geometry database. Code changes? AZ
  • G. modify PDT error after calib muo_util DH
  • H. use the same hit on 2 segments PB/CR?
  • .

2
II. Segments
  • A. allow close segments
    OP
  • in muo_segmentlinkedlist cvs.
  • B. allow one hit/plane for PDT fits
    OP
  • muo_segmentlinked list. In cvs
  • C. SegmentParams direction bug? MW
  • vx,vy,vz in corners
    MW
  • muo_segment (could also add noWirePlanes
    and Index methods)
  • D. central scints on segments. Use both views
    to selectuse in fitsallow 2 a-phi
    RS/DH
  • muo_segmentlinkedlist
  • E. change best selection to use no. of planes
    ??
  • muo_segmentlinkedlist
  • F. correct Time for TOF muo_segment MEads/DH
  • G. Timing cuts (or flag) on segments
    PB/CR?
  • H. Study events where B and C not associated and
    where scint hit not associated. Tune rcp RS/DH

3
III. Tracks, etc
  • A. Scint only in muo_segmentreco. In cvs
    PdJ
  • B. mixed oriein. Soon in cvs
    PdJ
  • C. have different rcp parameters for F/W?
    ??
  • D. phi bu. muo_centralmatch in cvs. In t/p?
    BT
  • E. A stub fits
    GH
  • F. BC segments only (local muon pt) RS?/GH?
  • G. do we need to refit hits (and not use
    segment line fit) after complete tracking done
    ??
  • H. timing for L3
  • I. In muonIDdo not match gt1 central track to
    same muon track/segment
  • ANYTHING ELSE?
  • MC vs data studies, influence of minbias events

4
PDT DeltaT Studies
  • Releases after p10.13 partially correct for time
    slewing by using an effective velocity of 0.9c
  • look at hits on good central A segments (1 scint
    plus 3PDT). Top, side, and bottom span PDT
    lengths. Enhancements at far and electronic
    ends
  • see enhancement at middle of wire if only single
    time (octant0 mostly)
  • tune DT to position function by comparing to
    location of a-phi counter. Plot
  • (positionPDT-positionScint) vs PositionScint
  • Can also compare A segment to BC segment for
    side octants where PDTs have flipped
    orientation
Write a Comment
User Comments (0)
About PowerShow.com