Title: Presentation%20on%20Applications%20of%20Network%20Management%20Using%20UHF%20-%20Microwave%20Links.


1
Presentation on Applications of Network
ManagementUsing UHF - Microwave Links.
  • Paper Presented By
  • Sunil V.Vyas
  • Digital Integrator Pvt. Ltd., India.
  • Digiint_at_sancharnet.in digvijaysvyas_at_hotmail.com

2
Application of Network Management
  • We are managing a Network of Indian Railways (
    Microwave Repeater Station ) which is a main
    source of Communication media for Indian
    Railways.
  • What We have a Number of Divisions in the
    Regional Railways e.g.. Western Railways, and
    these Divisions are having divisional HQ.

3
Cont..

4
NMS
  • These divisional Head Quarters are looking after
    the administration of Railways Traffic in the
    division. All divisions are almost having Railway
    Track of almost 200 to 250 kms. Consisting 5 to 7
    Repeaters of Microwave Network in the division.
  • The mainpurpose of These repeater is to boost the
    signal and continue the communication link for
    smooth working in the division.

5
NMS by DIPl, Indore India
  • Every Repeater Station is isolated by almost 55
    to 60 kms. Distance ,this depends upon the
    terrain of the region.
  • There are many equipment housed at these stations
    in order to make communication workable, like
    Transmitters (2 nos.) , Receivers( 02), 24 V
    Power Supply , stand by supply (secondary) using
    Battery Bank, Stand by Battery Bank, D/ Generator
    set, Battery Charger, Float, SPV Supply , Air
    conditioner Set etc.

6
NMS by DIPL, Indore. India.
  • These Transmitters and Receivers are having many
    important Analog and Digital signals. These
    Signals are presently monitored Manually , i.e..
    24 hrs . Man Power is provided at all these
    locations. But efficiency and duty attendance is
    poor. In order to get better efficiency we have
    devised a system called NMS for MW .
  • Almost 100 Analog and 56 Digital Important
    Signals are required to be monitored and some to
    the extent of 16 Digital Out Signals for
    controlling devices like
  • Switching of Transmitter,
  • Switching of Receivers,
  • Switching of Battery Bank from Load to Charger
    and Charger to Load in secured way .
  • Switching On/ off Diesel Generator Set
  • Switching On/ Off SPV supply .
  • Monitoring of Room Temp Switching Air
    conditioner.
  • And On top of this all Remotely sitting at the
    Divisional Railways HQ.

7
NMS by DIPL, Indore. India
  • One can do it using system developed by us.
  • We have Developed following components
  • Data Loggers stationed at all the stations for
    Data acquisition of the signals of local
    station.Compatible to requirement of nos. of
    Analog and Digital Signals.
  • These Data Loggers are connected to each other in
    daisy chaining /Multi drop Network topology and
    finally to FEP Front End Processor and then To
    FAS Front Analyzer System through Memory Buffer.
    Application software and Truth / Lookup tables
    are residing in FIFO memory Buffer.

8
(No Transcript)
9
NMS by DIPL, Indore INDIA
1 Rep. Stn
2 stn
10
NMS by DIPL, Indore. India
  • Data Logger

LDC Display 16 X 2
11
NMS, by DIPL, Indore. India
  • Strategy of connectivity of Network

FEP
Mem.Buf
1Dl
2Dl
nDl
FAS
12
NMS by DIPL, Indore. India
  • Connectivity of Network
  • All the Data Loggers are connected to Radio link
    of Microwave through Modem which is addressable.
  • FEP is connected to Memory Buffer and keep
    acquiring data from Buffer.
  • Memory Buffer is in continuos poling mode and
    keep acquiring data from all the data loggers .
  • FAS is connected to FEP and can remotely access
    and control the activity of the system.

13
NMS by DIPL, Indore. India
  • Thanks to ICTP and Mr.. S.M. Radicilla, Mr. R.
    Struzack for giving me this opportunity.
  • Thank to Viewers for patient listening
  • Thanks to Mr. Carlo Fonda for all his support.
  • Sunil Vyas. Digvijaysvyas_at_hotmail.com
  • digiint_at_sancharnet.in
Write a Comment