Title: The PHILIS Support Contract to the U'S' EPA National Decontamination Team


1
The PHILIS Support Contract to the U.S.
EPANational Decontamination Team
  • Site Visit for the Portable High-Throughput
    Integrated Laboratory Identification System
    (PHILIS)July 21st, 2009
  • National Decontamination Team
  • US EPA Special Teams

2
So what is the PHILIS ?
  • It is a national asset of the EPA for the
    analysis of CWAs/ITCs on site
  • Collection of mobile analytical systems at 3
    locations across the US
  • It is a full function lab on wheels performing
    EPA validated methods producing data of known
    QA/QC integrity
  • It is not a disaster only asset

3
PHILIS Mission
  • Fill perceived EPAs gaps in the nations capacity
    to analyze for CWAs in environmental samples
  • Provide on-site analysis for TICs and CWAs
  • Reduce time to recovery for critical
    infrastructure
  • Validate (through the ERLN) CWA analytical
    methods
  • Dual Use Add to EPAs analytical assets
  • Provide surge capacity for EPA Regional and
    Program laboratories in response to non-WMD
    events natural disasters, accidents, spills
  • On-site analytical assets on EPA Superfund clean
    up sites
  • Train chemists for EPAs Laboratory Support
    Response Corps

4
A Little Background
  • EPAs Chemical Surety Program
  • PHILIS 1
  • PHILIS 2

5
PHILIS Goals
  • Provides the EPA with mobile, on-site analytical
    capability for the analysis of CWAs in soil,
    surface, water and air matrices
  • Augment EPAs capacity to analyze CWAs in an
    emergency response (surge capacity)
  • Participate in validation of EPA analytical
    methods (SAM) for the CWAs
  • Provide real-time, on-site data to EPAs response
    and remedial staff for the timely, cost-effective
    mitigation and recovery of site contaminated by
    CWAs (or TICs/TIMs) due to a terrorist attacks
  • Provide analysis of TICs/TIMs in the event of a
    natural disaster or accidental spills or releases

6
PHILIS 1 to PHILIS 2
  • The best aspects of the three PHILIS 1 systems
    were used to construct the new PHILIS 2 prototype
    (PHILBERT son of PHILIS)
  • GC/MS w/FPD
  • Pressurized solvent extraction sample prep (PSE)
  • LC/MS-MS added
  • LIMS
  • The remaining PHILIS 1 assets were used as a
    starting point to construct new PHILBERT systems
    (pending in NJ and CO)
  • 10 GC/MS systems (NJ)
  • 3 TOF GC/MS systems (CO)
  • SPE sample prep (CO)
  • 1 LC/MS-MS added (NJ)
  • 2 - P T systems added (NJ)

7
Upgrade Existing PHILIS -1 assets to PHILIS-2
capabilities
  • Automated sample prep
  • Ultra-dilute Agent Security Room
  • GC/MS system
  • LC/MS-MS system
  • Wireless, encrypted LIMS

8
PHILIS 1 - NJ
  • PHILIS 1 units arrived in Edison, NJ and Erlanger
    KY in July 2007. Currently running under
    temporary shore power and shelter
  • Currently capable of only analyzing TICs (method
    8260/8270)
  • Edison unit includes 10 GC/MS instruments and a
    sample prep trailer. Two P T, LC/MS-MS
    recently (October 2008) added.
  • A Sample Log-in and Area (SLA) trailer needed
  • NDT will work with ERT and Region 2 emergency
    response program and laboratory on initial set up
    of lab.

9
NJ PHILIS
10
PHILIS Status - NJ
  • Have Modified PHILIS 1 Systems
  • 2 24 bed lab trucks (APL01, APL02)
  • 1 24 bed 5th wheel trailer w/Ford 550 for
    sample prep (SPA)
  • 1 12 bed refrigerated box truck
  • 10 GC/MS systems
  • 2 PT systems for VOCs
  • 1 LC/MS-MS system (not in PHILIS, in Region 2
    fixed laboratory)
  • Need Finalize Permanent shore power and shelter
    solution
  • Warehouse space construction completed, HS
    issues linger
  • Support offices, storage, meeting/training rooms
  • Link in with Region 2 and EPA Lab Response Corps
  • SLA trailer w/UDA CWA standards secure room
  • LIMS upgrade underway

11
PHILIS 1 CO
  • Denver PHILIS unit includes sample prep trailer
    and mobile laboratory bus with 3 time of flight
    (TOF) GC/MS systems.
  • Warehouse construction is currently underway,
    with a late August completion date
  • Automated sample prep equipment and a SLA trailer
    needed
  • Units have potential to accelerate GC analysis
    time. Rapid GC/TOF-MS methods currently being
    developed and validated by NHSRC and NEIC

12
CO PHILIS
13
Time of Flight (TOF) GC/MSCO PHILIS
  • Fast GC and TOF/MS

14
PHILIS Status - CO
  • Have Modified PHILIS 1 System
  • 1 45 mobile lab RV (PAL)
  • 1 53 sample prep trailer (SPA)
  • 3 TOF GC/MS systems w/rapid GC
  • 3 SPE systems for SVOCs
  • Need - Permanent shore power and shelter solution
  • Complete construction on warehouse, end of August
    2009
  • Link in with NCERT/NEIC for TOF methodologies
  • SLA trailer w/UDA CWA standards secure room
  • VOCs sample prep system (PT systems)
  • Upgrade of SVOCs sample prep system (PSE systems)
  • LIMS upgrade

15
PHILIS 2 (PHILBERT) - KY
  • Flagship PHILIS Unit
  • Mobile laboratory consortium of 3 vehicles
  • Analytical Trailer with 6 GC/MS systems and one
    LC/MS/MS system
  • Sample Preparation Trailer for prep. operations
    of soil, water, air, and wipe samples.
  • Sample Log-In and Standards (ultra-dilute CWAs)
    Storage trailer
  • Anticipated Capacity of 100 200 Toxic
    Industrial Chemical or Chemical Warfare Agent
    samples per 24 hr. period
  • Will analyze CWAs and their breakdown products
    using SW 846 methodologies found in Standardized
    Analytical Methods (SAM).
  • Delivered April 2008, warehouse renovations to
    current building underway for shore power and
    warehouse/office space.
  • Proposed location for CWA training and
    certification for EPAs Laboratory Response Corps
  • Prototype for EPAs future PHILIS systems

16
PHILBERT KYSPA and PAL Trailers
17
PHILBERT KYSLA Trailer (UD CWA Secure Room)
18
PHILBERT - KYLC/MS-MS System
19
PHILBERT Status - KY
  • Have One Complete PHILIS 2 system in KY
  • 1 53 lab trailer (PAL)
  • 1 53 sample prep trailer (SPA)
  • 1 - 24 bed 5th wheel trailer w/Ford 550 for
    sample log-in (SLA)
  • 6 - GC/MS w/FPD
  • 1 - LC/MS-MS
  • 3 - PSE automated sample prep for SVOCs
  • 2 - P T systems for VOCs
  • Wireless LIMS
  • Need Permanent shore power and shelter solution
  • Support offices, storage, meeting/training rooms
  • HVAC renovations as per HS requirements (if
    required)
  • Link in with Region 5/NHSRC LC/MS-MS methodology
    RD

20
PHILIS-2 Data Flow
Sample In/ Screening COC generated/LIMS
initiated Ultra-dilute CWA standards
Analysis of CWAs/SVOCs/VOCs 6 GC/MS
w/FPD 1-LC/MS-MS
Step 2-SLA Sample Log-in
Step 4-PAL Sample Analysis
LIMS connected
Automated Sample Prep Soil, water, wipes, air,
solids PSE/SPE/ P T
Sampling Info Scribe Format
Data Output Scribe Compatible
Step 3-SPA Sample Prep
Step 1- START Sample Collection
Step 5 Report Out Data to OSC/UC/EU
21
PHILIS Challenges
  • Method development and validation
  • SAM methods
  • LC/MS-MS methods
  • TOF rapid methods
  • CWA breakdown products
  • Integration of PHILIS into ERLN
  • Upgrades of PHILIS 1 units to PHILIS 2/PHILBERT
    capabilities
  • On-site analysis of CWAs and breakdown products
  • Dual Use at PHILIS systems (ie Superfund sites)

22
Site Visit Health Safety
  • Slip, trips and spill hazards
  • Watch for extension cords, cables
  • Equipment on the floor
  • Lighting not uniform
  • Stairs and decks
  • High heels/shoes can get stuck in gratings

23
Questions