Title: LST Gas System
1LST Gas System
- R. Messner
- May 2004
- Readiness Review
2Will cover a few of the items below
- Gas Mix the issue of what gas mixtures will be
allowed in the LST system has been resolved - FHA ONeill, Budnick
- HEEC review
- Gas Mixing System
- In leak test
- Want to test output flows ASAP
- Integrate with the GIB
- Gas Interrupt Box (GIB)
- Finished with checkout
- Had found problems with firmware fixed
- IR-2 Distribution Panels
- Flow restrictor in hand, checked out
- Gas Supply Manifolds
- Next to be assembled
3Gas Mix Instead of getting a specific mix
approved, we want approval for a region of mixes
4Gas Mix The operating region takes into account
the stability we have seen in the RPC system
5Mixing System Functionality
A fourth mass flow meter can provide a
tie-breaking vote in case of MFM/MFC
disagreement Can also pick up small drifts in
mixed gas flows
Shut-off solenoids will close if the gas mix
drifts out of the allowed region
6Gas Rack - in leak test
7Gas Rack
8Gas Interrupt Box Functionality
9GIB in checkout
10Overview of the IR-2 Distribution
11Silica tubing flow resistor
12Check of silica tubing flow resistance
13Gas Shack Layout
Two new inert gas supplies Each will have a
shutoff valve, orifice, overpressure releases
Construct a new isobutane supply rack and
manifold Will have two isobutane shutoff valves,
orifice
14Summary
- The loose ends involved in determining a
permissible gas mix have been resolved - Very close to having a functional mixing system
with its monitor system to ensure a non-flammable
and a runnable mix - Use air or nitrogen, check the self consistency
and stability of system - It is important to keep moving ahead sufficient
and timely technical support is critical - Want the gas rack in the gas shack before the end
of May - Delayed a bit because we want to get the
manifolds done first then we can do more things
in parallel - Expansion of Gas Shack safety system in progress
- EPICs monitor system will be the next item to
attack
15Spare Slides
16Looked at the recent performance of the RPC
system
Snapshots taken a week apart, a half day at a
time This is a measure of the stability of the
gas mixture
- 0.0005 out of 0.045 Or 1.0 of the
reading
17Recent performance of the RPC system
Isobutane Fraction in Gas Mixture