Title: Comparison of Microcoaxial and Clear Corneal Incision Using Visante OCT


1
Comparison of Microcoaxial and Clear Corneal
Incision Using Visante OCT
  • Mariana Ávila, MD
  • Adriana Forseto, MD, Phd
  • Walton Nosé, MD, Phd
  • Eye Clinic Day Hospital - SÃO Paulo - Brazil
  • Unifesp - SÃO Paulo - Brazil
  • The authors do not have any financial interest

2
Purpose
To investigate microcoaxial and clear corneal
incision (CCI) architecture in the postoperative
period using non-contact anterior segment optical
coherence tomography (Visante OCT ,Carl Zeiss)
3
Methods
  • Prospective study
  • 30 patients submitted to phaco
  • Incision
  • Microcoaxial 2.20 mm width (15 eyes)
  • Clear corneal 2.75 mm width (15 eyes)
  • IOL implantation
  • Monarch injector
  • Cartridge C

4
Methods
  • Postoperative evaluation
  • 1st day, 1st and 3rd months
  • Slitlamp examination
  • Seidel test
  • IOP measurement
  • Visante OCT
  • Incision architecture
  • Configuration
  • Coaptation
  • Stability

5
Results
No Descemets Detachment was observed at
slitlamp examination
6
Visante OCT MicrocoaxiaL Incision
  • Detachment of Descemets membrane
  • 1 day postoperative

1 month postoperative
7
Visante OCT Clear Corneal Incision
1 day postoperative
8
Visante OCT MicrocoaxiaL x Clear corneal
Incisions
Microcoaxial Straight line configuration
Clear Corneal Arcuate configuration
9
Results
10
Results
11
Conclusions
  • Visante OCT analysis of Microcoaxial and
    Clear Corneal Incision post phaco showed
  • a higher percentage of Descemets Detachment in
    the Microcoaxial group at the 1st postoperative
    day
  • that localized detachment of Descemets membrane
    may be more common than observed with slit-lamp
    microscopy
  • different incisions' configurations between the
    two groups with no difference regarding proper
    coaptation and stability.