Title: What if you could reduce AC energy costs 20 40%
1- What if you could reduce AC energy costs 20 -
40? - What if someone else paid 40 of the system cost?
- What if you helped the environment too?
2The 5th Ice Age
- Off-Peak Cooling AC for the 21st Century
Hydro Ottawa Powerful Alternatives November 26,
2008
3Off-Peak Cooling Process
Make Store Cool Energy
Discharge Energy As Needed
4OPC For Air Conditioning
5Why Off-Peak Cooling?
- 2008 Summer Seasonal Off-Peak Average 64 Lower
- Apr 1 Sep 30, 2008
- 75 of days ? 50 lower
- 60 of days ? 60 lower
- 2007 Summer Seasonal Off-Peak Average 52 Lower
6Building Load Profile
7Building with OPC / TES Profile
8Full Load Shift
ON - PEAK DEMAND REDUCTION
9Partial Load Shift
1200
1000
800
ON - PEAK DEMAND REDUCTION
Chiller Size
Tons
600
400
200
0
12
12 Noon
600 AM
600 PM
Hour
10OPC Summary of Benefits
Electricity
- Incentives (i.e. ERIP)
- 150 - 400 per kW peak load reduction
- up to 40 project cost
- Chillers
- right-size reduce capital cost
- improved efficiency/performance reduce
operating/maintenance costs - Water
- conserve, reduce cost
- Environment
- reduce GHG
- lower carbon footprint
Cost Use Peak Load
11Thermal Energy Storage
Ice Ball from Innovative Cooling Technologies
12TES Technologies
13Ice BallTM Encapsulated Ice
14Ice BallTM Highest Surface Area
- Ice Ball
- 24 ft2 surface area per ton-hour
- higher cooling capacity per volume
- Ice-on-Coil
- 7 17 ft2
- requires more energy to produce equivalent cooling
15Ice BallTM Containment Flexibility
16Ice BallTM Tank Design
ice limiting controls many joints welds biocide
treatment air pumps winterization
17Ice BallTM Environmental
18OPC - Applications
- Commercial Air Conditioning
- Offices, Hospitals, Schools, Retail Stores,
Airports, Hotels, Data Centers, Convention
Centers - 35 100 Load Shifting
- Process Cooling
- Breweries, Dairies, Plastic / Synthetic fiber
manufacturing - Partial peak load reduction
- Refrigeration
- Grocery /Food wholesalers and retailers
- Food processing
- Typically 25 peak load reduction
19TES Geothermal
- Smaller Heat Pump
- reduce capital cost
- reduce energy consumption
- energy cost savings
- Smaller Geo-exchanger
- 30 50 size reduction
- significant cost saving
- save real estate
- viable for smaller sites
- 25 50 Peak Load Shift
- Community Centers, Arenas
20Off-Peak Cooling by the Numbers
21Off-Peak Cooling by the Numbers
22Summary
Electricity
Cost Use Peak Load
- TES Off-Peak Cooling
- AC that pays for itself
- no longer sunk cost
- AC with incentives
- Contributes to LEEDS BOMA Go Green points
23Off-Peak CoolingAir conditioning for the 21st
century
- Contact Larry Trenwith, 613-907-1806
- Email ltrenwith_at_ictcanadaltd.com
- Web www.offpeakcooling.ca